Cervical Medial Branch Radiofrequency Ablation Using Bipolar Multi-Tined Cannulae in a Patient with an Implanted Cervical Spinal Cord Stimulator: A Case Report.

Pain medicine case reports Pub Date : 2026-09-01
Joel Peltonen, Yehia Kamel
{"title":"Cervical Medial Branch Radiofrequency Ablation Using Bipolar Multi-Tined Cannulae in a Patient with an Implanted Cervical Spinal Cord Stimulator: A Case Report.","authors":"Joel Peltonen, Yehia Kamel","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cervical medial branch radiofrequency ablation (RFA) is an established treatment for chronic cervical facet joint pain. However, RFA procedures generate electromagnetic interference (EMI) that can pose a significant safety risk, potentially leading to spontaneous activation or damage of implanted electronic devices, such as spinal cord stimulators (spinal cord stimulation [SCS]). Previous reports have highlighted the successful use of conventional bipolar RFA, but data are limited regarding large-volume lesioning techniques in patients with SCS implants.</p><p><strong>Case report: </strong>A 70-year-old man, who had a prior C7-T1 fusion and an implanted cervical SCS for refractory radicular pain, presented with axial neck pain. Following confirmation via diagnostic medial branch blocks (MBBs), the patient underwent cervical medial branch RFA using a bipolar multi-tined cannula technique. Strict protocols, including turning off the SCS device and performing neurophysiological monitoring, ensured the procedure was completed safely without complications or device malfunction.</p><p><strong>Conclusions: </strong>This case demonstrates the safe and effective application of bipolar multi-tined RFA, a large-volume lesioning technique, in a patient with a cervical SCS implant. This approach leverages bipolar configuration and minimizes current dispersion, offering clinicians an important alternative to mitigate EMI risks and achieve durable pain relief in this complex patient population.</p>","PeriodicalId":520525,"journal":{"name":"Pain medicine case reports","volume":"10 7","pages":"591-595"},"PeriodicalIF":0.0000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pain medicine case reports","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Cervical medial branch radiofrequency ablation (RFA) is an established treatment for chronic cervical facet joint pain. However, RFA procedures generate electromagnetic interference (EMI) that can pose a significant safety risk, potentially leading to spontaneous activation or damage of implanted electronic devices, such as spinal cord stimulators (spinal cord stimulation [SCS]). Previous reports have highlighted the successful use of conventional bipolar RFA, but data are limited regarding large-volume lesioning techniques in patients with SCS implants.

Case report: A 70-year-old man, who had a prior C7-T1 fusion and an implanted cervical SCS for refractory radicular pain, presented with axial neck pain. Following confirmation via diagnostic medial branch blocks (MBBs), the patient underwent cervical medial branch RFA using a bipolar multi-tined cannula technique. Strict protocols, including turning off the SCS device and performing neurophysiological monitoring, ensured the procedure was completed safely without complications or device malfunction.

Conclusions: This case demonstrates the safe and effective application of bipolar multi-tined RFA, a large-volume lesioning technique, in a patient with a cervical SCS implant. This approach leverages bipolar configuration and minimizes current dispersion, offering clinicians an important alternative to mitigate EMI risks and achieve durable pain relief in this complex patient population.

颈椎内侧支射频消融术应用于植入颈脊髓刺激器患者一例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书