Auditory Brainstem Response Binaural Interaction Components Measured With Low-Frequency Tone Bursts: Correlations With Behavioral Binaural Measures.

IF 1.7 4区 医学 Q3 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
So Eun Park, Noah Neil Dawson Cowley, Marcy K Hite
{"title":"Auditory Brainstem Response Binaural Interaction Components Measured With Low-Frequency Tone Bursts: Correlations With Behavioral Binaural Measures.","authors":"So Eun Park, Noah Neil Dawson Cowley, Marcy K Hite","doi":"10.1044/2026_AJA-26-00028","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to identify electrophysiological markers of binaural processing at the brainstem level and examine whether they may serve as electrophysiological correlates of behavioral performance in young adults with normal hearing.</p><p><strong>Method: </strong>Twenty-nine young adults (21-29 years) with symmetric normal hearing (≤ 20 dB HL) were tested. Binaural processing was measured using the binaural interaction component (BIC) of the auditory brainstem response (ABR) elicited by 250- and 500-Hz tone bursts. Behavioral performance was assessed with three tasks: spondee binaural fusion (SBF), 500-Hz masking level difference, and auditory figure-ground.</p><p><strong>Results: </strong>For ABR-BIC latency, VI<sub>d</sub> occurred later than V<sub>d</sub>, and both waves showed longer latencies at 250 Hz than at 500 Hz. The later timing of VI<sub>d</sub> could be associated with later processing along more rostral auditory pathways. At 500 Hz, V<sub>d</sub> amplitude was significantly larger than VI<sub>d</sub>, whereas amplitudes were comparable at 250 Hz, suggesting that VI<sub>d</sub> may be relatively preserved at lower frequencies. ABR-BIC VI<sub>d</sub> amplitude at 250 Hz correlated significantly with SBF scores, with larger VI<sub>d</sub> amplitudes associated with higher scores.</p><p><strong>Conclusions: </strong>ABR-BIC Waves V<sub>d</sub> and VI<sub>d</sub> may reflect different electrophysiological aspects of brainstem-level binaural processing. VI<sub>d</sub> amplitude at 250 Hz may serve as a preliminary electrophysiological correlate of binaural fusion performance, although this single association should be interpreted cautiously and replicated in future studies. ABR-BIC may have potential as an objective supplement to behavioral binaural measures, although further validation is needed.</p>","PeriodicalId":49241,"journal":{"name":"American Journal of Audiology","volume":" ","pages":"1-15"},"PeriodicalIF":1.7000,"publicationDate":"2026-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Audiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1044/2026_AJA-26-00028","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study aimed to identify electrophysiological markers of binaural processing at the brainstem level and examine whether they may serve as electrophysiological correlates of behavioral performance in young adults with normal hearing.

Method: Twenty-nine young adults (21-29 years) with symmetric normal hearing (≤ 20 dB HL) were tested. Binaural processing was measured using the binaural interaction component (BIC) of the auditory brainstem response (ABR) elicited by 250- and 500-Hz tone bursts. Behavioral performance was assessed with three tasks: spondee binaural fusion (SBF), 500-Hz masking level difference, and auditory figure-ground.

Results: For ABR-BIC latency, VId occurred later than Vd, and both waves showed longer latencies at 250 Hz than at 500 Hz. The later timing of VId could be associated with later processing along more rostral auditory pathways. At 500 Hz, Vd amplitude was significantly larger than VId, whereas amplitudes were comparable at 250 Hz, suggesting that VId may be relatively preserved at lower frequencies. ABR-BIC VId amplitude at 250 Hz correlated significantly with SBF scores, with larger VId amplitudes associated with higher scores.

Conclusions: ABR-BIC Waves Vd and VId may reflect different electrophysiological aspects of brainstem-level binaural processing. VId amplitude at 250 Hz may serve as a preliminary electrophysiological correlate of binaural fusion performance, although this single association should be interpreted cautiously and replicated in future studies. ABR-BIC may have potential as an objective supplement to behavioral binaural measures, although further validation is needed.

用低频音调爆发测量听觉脑干反应双耳相互作用成分:与行为双耳测量的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
American Journal of Audiology
American Journal of Audiology AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY-OTORHINOLARYNGOLOGY
CiteScore
3.00
自引率
16.70%
发文量
163
审稿时长
>12 weeks
期刊介绍: Mission: AJA publishes peer-reviewed research and other scholarly articles pertaining to clinical audiology methods and issues, and serves as an outlet for discussion of related professional and educational issues and ideas. The journal is an international outlet for research on clinical research pertaining to screening, diagnosis, management and outcomes of hearing and balance disorders as well as the etiologies and characteristics of these disorders. The clinical orientation of the journal allows for the publication of reports on audiology as implemented nationally and internationally, including novel clinical procedures, approaches, and cases. AJA seeks to advance evidence-based practice by disseminating the results of new studies as well as providing a forum for critical reviews and meta-analyses of previously published work. Scope: The broad field of clinical audiology, including audiologic/aural rehabilitation; balance and balance disorders; cultural and linguistic diversity; detection, diagnosis, prevention, habilitation, rehabilitation, and monitoring of hearing loss; hearing aids, cochlear implants, and hearing-assistive technology; hearing disorders; lifespan perspectives on auditory function; speech perception; and tinnitus.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书