Inferior vena cava filter retrieval with radial jaw biopsy forceps: a case report.

IF 0.6 Q3 MEDICINE, GENERAL & INTERNAL
AME Case Reports Pub Date : 2026-06-23 eCollection Date: 2026-01-01 DOI:10.21037/acr-2026-0094
Baylor Akhavan, Brian Kerlin, Rachel Soong, Alexander Kieger, Brandon Chen
{"title":"Inferior vena cava filter retrieval with radial jaw biopsy forceps: a case report.","authors":"Baylor Akhavan, Brian Kerlin, Rachel Soong, Alexander Kieger, Brandon Chen","doi":"10.21037/acr-2026-0094","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Inferior vena cava (IVC) filters are used in patients at risk for venous thromboembolism (VTE) who cannot receive anticoagulation. Prolonged dwell times are associated with increased risk of embedment, endothelialization, and retrieval failure, often necessitating advanced techniques. While endobronchial forceps are commonly used in complex retrievals, the role of alternative biopsy devices remains limited. We present the following case highlighting the use of radial jaw biopsy forceps for IVC filter retrieval, a technique with minimal prior documentation.</p><p><strong>Case description: </strong>A man in his late 30s with a history of recurrent deep vein thromboses presented with progressive bilateral lower extremity swelling and an indwelling IVC filter with an estimated dwell time of approximately 5 years. Imaging demonstrated severe iliocaval obstruction and collateral formation. Initial retrieval attempts using standard snare, loop snare, and hangman techniques were unsuccessful due to fibrotic encapsulation and deformation of the filter. In the absence of rigid endobronchial forceps, radial jaw biopsy forceps were utilized to dissect fibrous tissue and successfully engage and remove the filter. Residual struts were excluded with bilateral iliac vein stenting, resulting in improved venous outflow.</p><p><strong>Conclusions: </strong>Radial jaw biopsy forceps may serve as a viable alternative in complex IVC filter retrieval when conventional and advanced techniques fail or are unavailable. This case expands the spectrum of available tools and highlights the importance of procedural adaptability in interventional radiology (IR).</p>","PeriodicalId":29752,"journal":{"name":"AME Case Reports","volume":"10 ","pages":"166"},"PeriodicalIF":0.6000,"publicationDate":"2026-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13659148/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AME Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21037/acr-2026-0094","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Inferior vena cava (IVC) filters are used in patients at risk for venous thromboembolism (VTE) who cannot receive anticoagulation. Prolonged dwell times are associated with increased risk of embedment, endothelialization, and retrieval failure, often necessitating advanced techniques. While endobronchial forceps are commonly used in complex retrievals, the role of alternative biopsy devices remains limited. We present the following case highlighting the use of radial jaw biopsy forceps for IVC filter retrieval, a technique with minimal prior documentation.

Case description: A man in his late 30s with a history of recurrent deep vein thromboses presented with progressive bilateral lower extremity swelling and an indwelling IVC filter with an estimated dwell time of approximately 5 years. Imaging demonstrated severe iliocaval obstruction and collateral formation. Initial retrieval attempts using standard snare, loop snare, and hangman techniques were unsuccessful due to fibrotic encapsulation and deformation of the filter. In the absence of rigid endobronchial forceps, radial jaw biopsy forceps were utilized to dissect fibrous tissue and successfully engage and remove the filter. Residual struts were excluded with bilateral iliac vein stenting, resulting in improved venous outflow.

Conclusions: Radial jaw biopsy forceps may serve as a viable alternative in complex IVC filter retrieval when conventional and advanced techniques fail or are unavailable. This case expands the spectrum of available tools and highlights the importance of procedural adaptability in interventional radiology (IR).

下腔静脉滤器取取桡颌活检钳1例。
背景:下腔静脉(IVC)过滤器用于有静脉血栓栓塞(VTE)风险且不能接受抗凝治疗的患者。延长的停留时间与植入、内皮化和取出失败的风险增加有关,通常需要先进的技术。虽然支气管内钳通常用于复杂的取出,但替代活检装置的作用仍然有限。我们提出以下病例,强调使用桡颌活检钳进行下腔静脉滤过器检索,这是一种很少有文献记录的技术。病例描述:一名30多岁的男性,有复发性深静脉血栓病史,表现为进行性双侧下肢肿胀,下腔静脉滤器留置,估计留置时间约为5年。影像学显示严重髂腔梗阻及侧支形成。由于过滤器的纤维包封和变形,使用标准陷阱、环陷阱和hangman技术的初始检索尝试都不成功。在没有刚性支气管内钳的情况下,桡骨颌活检钳被用来解剖纤维组织,并成功地接合和去除过滤器。双侧髂静脉支架置入术排除残余支撑物,改善静脉流出。结论:当传统和先进技术失败或不可用时,桡骨颌活检钳可作为复杂下腔静脉滤器取出的可行选择。该病例扩展了可用工具的范围,并强调了介入放射学(IR)程序适应性的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书