Pitfalls in lung subtraction CT: delayed contrast acquisition causes underestimation of pulmonary perfusion in a canine model.

IF 2 4区 农林科学 Q1 VETERINARY SCIENCES
Kentaro Yamazaki, Kosei Teraoka, Masayoshi Nagakawa, Chiharu Ito, Akari Taniguchi, Kodai Tashiro, Kazuya Kushida, Kija Lee, Yuki Hoshino, Yukiko Sassa-O'Brien, Miori Kishimoto
{"title":"Pitfalls in lung subtraction CT: delayed contrast acquisition causes underestimation of pulmonary perfusion in a canine model.","authors":"Kentaro Yamazaki, Kosei Teraoka, Masayoshi Nagakawa, Chiharu Ito, Akari Taniguchi, Kodai Tashiro, Kazuya Kushida, Kija Lee, Yuki Hoshino, Yukiko Sassa-O'Brien, Miori Kishimoto","doi":"10.1538/expanim.26-0160","DOIUrl":null,"url":null,"abstract":"<p><p>Lung subtraction computed tomography (LSCT), assessing pulmonary perfusion by subtracting non-contrast-enhanced images from contrast-enhanced images, may underestimate pulmonary perfusion when contrast-enhanced image acquisition is delayed. This study aimed to evaluate the effects of delayed acquisition of contrast-enhanced images on the LSCT assessment of pulmonary perfusion and identify indicators of sufficient contrast enhancement for LSCT generation using healthy beagles. Five beagles underwent continuous cine computed tomography (CT) for 30 s. After the second scan, iodixanol was intravenously administered. LSCT images were generated by subtracting pre-contrast images from contrast-enhanced images. On LSCT images, lung CT values and the percentage of areas with CT values of 0-20 HU were measured at the pulmonary trunk and tracheal bifurcation levels when the lung CT value on LSCT images was the highest and at 1.5 and 3.0 s thereafter. Pulmonary trunk CT values and pulmonary trunk-to-aorta (Pa/Ao) CT value ratios were recorded. Lung CT values decreased significantly over time, whereas the percentages of 0-20 HU areas increased. Pulmonary trunk CT values were associated positively with lung CT values and negatively with the percentages of 0-20 HU areas at both slice levels. Pa/Ao ratios showed similar significant associations at the pulmonary trunk level but not at the tracheal bifurcation level. In conclusion, delayed acquisition resulted in underestimation of pulmonary perfusion on LSCT images. These findings highlight the importance of appropriate acquisition timing. Pa/Ao ratios might indicate whether contrast enhancement is sufficient for LSCT generation.</p>","PeriodicalId":12102,"journal":{"name":"Experimental Animals","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2026-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Experimental Animals","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1538/expanim.26-0160","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Lung subtraction computed tomography (LSCT), assessing pulmonary perfusion by subtracting non-contrast-enhanced images from contrast-enhanced images, may underestimate pulmonary perfusion when contrast-enhanced image acquisition is delayed. This study aimed to evaluate the effects of delayed acquisition of contrast-enhanced images on the LSCT assessment of pulmonary perfusion and identify indicators of sufficient contrast enhancement for LSCT generation using healthy beagles. Five beagles underwent continuous cine computed tomography (CT) for 30 s. After the second scan, iodixanol was intravenously administered. LSCT images were generated by subtracting pre-contrast images from contrast-enhanced images. On LSCT images, lung CT values and the percentage of areas with CT values of 0-20 HU were measured at the pulmonary trunk and tracheal bifurcation levels when the lung CT value on LSCT images was the highest and at 1.5 and 3.0 s thereafter. Pulmonary trunk CT values and pulmonary trunk-to-aorta (Pa/Ao) CT value ratios were recorded. Lung CT values decreased significantly over time, whereas the percentages of 0-20 HU areas increased. Pulmonary trunk CT values were associated positively with lung CT values and negatively with the percentages of 0-20 HU areas at both slice levels. Pa/Ao ratios showed similar significant associations at the pulmonary trunk level but not at the tracheal bifurcation level. In conclusion, delayed acquisition resulted in underestimation of pulmonary perfusion on LSCT images. These findings highlight the importance of appropriate acquisition timing. Pa/Ao ratios might indicate whether contrast enhancement is sufficient for LSCT generation.

肺减影CT的缺陷:延迟造影剂采集导致犬模型肺灌注低估。
肺减影计算机断层扫描(LSCT)通过从对比增强图像中减去非对比增强图像来评估肺灌注,当对比增强图像采集延迟时,可能会低估肺灌注。本研究旨在评估延迟获取对比度增强图像对肺灌注LSCT评估的影响,并使用健康的比格犬确定LSCT产生的足够对比度增强指标。对5只小猎犬进行了30秒的连续CT扫描。第二次扫描后,静脉注射碘沙醇。LSCT图像是由对比度增强图像减去对比度前图像生成的。在LSCT图像上,当LSCT图像上肺部CT值最高时,在1.5 s和3.0 s时,分别在肺干和气管分叉水平测量肺部CT值和CT值为0 ~ 20 HU的区域百分比。记录肺干CT值及肺干与主动脉(Pa/Ao) CT值比。随着时间的推移,肺部CT值明显下降,而0-20 HU区域的百分比增加。肺干CT值与肺CT值呈正相关,与两层0-20 HU面积百分比呈负相关。Pa/Ao比值在肺干水平上显示相似的显著相关性,而在气管分叉水平上则无显著相关性。总之,延迟采集导致LSCT图像上肺灌注的低估。这些发现强调了适当的获取时机的重要性。Pa/Ao比值可能表明对比度增强是否足以产生LSCT。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Experimental Animals
Experimental Animals 生物-动物学
CiteScore
2.80
自引率
4.20%
发文量
2
审稿时长
3 months
期刊介绍: The aim of this international journal is to accelerate progress in laboratory animal experimentation and disseminate relevant information in related areas through publication of peer reviewed Original papers and Review articles. The journal covers basic to applied biomedical research centering around use of experimental animals and also covers topics related to experimental animals such as technology, management, and animal welfare.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书