How consistent is the determination of the anaerobic threshold among members of the same cardiac rehabilitation team?

IF 4.3 3区 医学 Q2 PHYSIOLOGY
Frontiers in Physiology Pub Date : 2026-09-30 eCollection Date: 2026-01-01 DOI:10.3389/fphys.2026.1914264
Nanaho Minagawa, Kazuo Kondo, Hirotaka Nishijima, Yusuke Mori, Takeo Ikota
{"title":"How consistent is the determination of the anaerobic threshold among members of the same cardiac rehabilitation team?","authors":"Nanaho Minagawa, Kazuo Kondo, Hirotaka Nishijima, Yusuke Mori, Takeo Ikota","doi":"10.3389/fphys.2026.1914264","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Consistency in the anaerobic threshold (AT) determination is essential for cardiac rehabilitation teams comprising multiple professionals who conduct cardiopulmonary exercise tests (CPETs) and interpret their results. The effect of years of experience on interpreting CPET results, including the AT, has been examined. However, consistency in the AT determination among members of the same institution with experience beyond the training period has not been reported.</p><p><strong>Methods: </strong>We evaluated consistency in the AT determination among four members at a cardiovascular hospital (three full-time physical therapists and one part-time consultant physician) with 4 to 30 years of experience with CPETs. Another full-time physical therapist acted as the controller and did not participate in the AT reading. This retrospective study used 260 blinded and randomized CPET data files from 130 patients (130 data pairs comprising inpatient and outpatient data). All observers determined the AT twice using the modified V-slope method.</p><p><strong>Results: </strong>The mean AT values showed significant interobserver differences (p<0.001) driven by a slightly but significantly lower value determined by the consultant physician. No significant differences in the values determined by the three full-time staff members were observed. Despite interobserver differences during inpatient and outpatient phases, the longitudinal change in the AT did not differ significantly (p=0.58). The intrarater reliability of four observers was good [intraclass correlation coefficient (1,1) = 0.87-0.94], with limits of agreement of 103.6 to 185.0 mL/min. The inter-rater reliability was also good [intraclass coefficient (2,1) = 0.87], with limits of agreement of observer pairs of 139.2 to 220.5 mL/min. Reliability was not associated with years of experience.</p><p><strong>Conclusions: </strong>Good consistency in the AT determination is achievable in a clinical setting. Adherence to a single standardized method across the team likely facilitates this consistency and provides a reliable objective measure for monitoring exercise tolerance.</p>","PeriodicalId":12477,"journal":{"name":"Frontiers in Physiology","volume":"17 ","pages":"1914264"},"PeriodicalIF":4.3000,"publicationDate":"2026-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13661349/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Physiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3389/fphys.2026.1914264","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Consistency in the anaerobic threshold (AT) determination is essential for cardiac rehabilitation teams comprising multiple professionals who conduct cardiopulmonary exercise tests (CPETs) and interpret their results. The effect of years of experience on interpreting CPET results, including the AT, has been examined. However, consistency in the AT determination among members of the same institution with experience beyond the training period has not been reported.

Methods: We evaluated consistency in the AT determination among four members at a cardiovascular hospital (three full-time physical therapists and one part-time consultant physician) with 4 to 30 years of experience with CPETs. Another full-time physical therapist acted as the controller and did not participate in the AT reading. This retrospective study used 260 blinded and randomized CPET data files from 130 patients (130 data pairs comprising inpatient and outpatient data). All observers determined the AT twice using the modified V-slope method.

Results: The mean AT values showed significant interobserver differences (p<0.001) driven by a slightly but significantly lower value determined by the consultant physician. No significant differences in the values determined by the three full-time staff members were observed. Despite interobserver differences during inpatient and outpatient phases, the longitudinal change in the AT did not differ significantly (p=0.58). The intrarater reliability of four observers was good [intraclass correlation coefficient (1,1) = 0.87-0.94], with limits of agreement of 103.6 to 185.0 mL/min. The inter-rater reliability was also good [intraclass coefficient (2,1) = 0.87], with limits of agreement of observer pairs of 139.2 to 220.5 mL/min. Reliability was not associated with years of experience.

Conclusions: Good consistency in the AT determination is achievable in a clinical setting. Adherence to a single standardized method across the team likely facilitates this consistency and provides a reliable objective measure for monitoring exercise tolerance.

在同一个心脏康复小组的成员中,厌氧阈的测定有多一致?
无氧阈值(AT)测定的一致性对于由多名进行心肺运动试验(cpet)并解释其结果的专业人员组成的心脏康复团队至关重要。多年的经验对解释CPET结果的影响,包括AT,已经被检验过了。但是,没有报告同一机构中具有培训期以外经验的成员在AT确定方面的一致性。方法:我们评估了一家心血管医院的四名成员(三名全职物理治疗师和一名兼职顾问医师)在cpet测定中的一致性,他们有4到30年的cpet经验。另一名全职物理治疗师作为控制者,不参与AT阅读。这项回顾性研究使用了来自130名患者的260个盲法随机CPET数据文件(130对数据包括住院和门诊数据)。所有观测者使用改进的v斜率法确定了两次AT。结果:平均AT值在观察者之间存在显著差异(结论:在临床环境中,AT测定具有良好的一致性。在整个团队中坚持单一的标准化方法可能有助于这种一致性,并为监测运动耐受性提供可靠的客观措施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.50
自引率
5.00%
发文量
2608
审稿时长
14 weeks
期刊介绍: Frontiers in Physiology is a leading journal in its field, publishing rigorously peer-reviewed research on the physiology of living systems, from the subcellular and molecular domains to the intact organism, and its interaction with the environment. Field Chief Editor George E. Billman at the Ohio State University Columbus is supported by an outstanding Editorial Board of international researchers. This multidisciplinary open-access journal is at the forefront of disseminating and communicating scientific knowledge and impactful discoveries to researchers, academics, clinicians and the public worldwide.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书