Pressure-Pressure Loop: A Novel Method for Biophysical Characterization of Blood Vessels.

IF 5.2 2区 医学 Q3 ENGINEERING, BIOMEDICAL
Zehava Ovadia-Blechman, Moshe Halak, Dor Ben Ishay, Efrat Rushinek Cohen, Shay Maman, Moran Aviv, Neta Rabin
{"title":"Pressure-Pressure Loop: A Novel Method for Biophysical Characterization of Blood Vessels.","authors":"Zehava Ovadia-Blechman, Moshe Halak, Dor Ben Ishay, Efrat Rushinek Cohen, Shay Maman, Moran Aviv, Neta Rabin","doi":"10.1007/s10439-026-04422-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To develop and evaluate a pressure-only method for localized functional characterization of synthetic vascular models and vascular grafts by capturing their integrated dynamic response and its interaction with stenosis severity.</p><p><strong>Methods: </strong>An in-vitro closed-loop pulsatile flow system tested seven vascular models and grafts (silicone, latex, ePTFE, Dacron) at 0, 50, and 90% lumen narrowing. Two proximal high-fidelity pressure sensors recorded intraluminal pressure waveforms to construct pressure-pressure loops. Loop behavior was evaluated qualitatively through loop morphology and quantitatively using the slope descriptor (α). Uniaxial tensile testing provided independent Young's modulus measurements.</p><p><strong>Results: </strong>Increasing stenosis altered pressure magnitude while characteristic loop patterns remained recognizable across conditions, with severe stenosis modifying specific features without eliminating broader patterns. Silicone models showed broad loops, latex models displayed complex crossing patterns, and vascular grafts exhibited narrow, near-linear loops. Loop morphology and the repeatable slope descriptor (α) were consistent across measurements, together differentiating the integrated, configuration-specific dynamic responses of the tested vascular models and grafts.</p><p><strong>Conclusion: </strong>Pressure-pressure loop analysis provides a novel pressure-only framework for functional characterization of vascular models and grafts. Combining qualitative loop morphology with a reproducible quantitative slope descriptor, the approach captures complementary features of the integrated dynamic pressure response rather than a single intrinsic material property. The study demonstrates the feasibility of extracting meaningful descriptors from two intraluminal pressure waveforms in-vitro, supporting future validation in native blood vessels and applications in vascular graft design.</p>","PeriodicalId":7986,"journal":{"name":"Annals of Biomedical Engineering","volume":" ","pages":""},"PeriodicalIF":5.2000,"publicationDate":"2026-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10439-026-04422-0","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To develop and evaluate a pressure-only method for localized functional characterization of synthetic vascular models and vascular grafts by capturing their integrated dynamic response and its interaction with stenosis severity.

Methods: An in-vitro closed-loop pulsatile flow system tested seven vascular models and grafts (silicone, latex, ePTFE, Dacron) at 0, 50, and 90% lumen narrowing. Two proximal high-fidelity pressure sensors recorded intraluminal pressure waveforms to construct pressure-pressure loops. Loop behavior was evaluated qualitatively through loop morphology and quantitatively using the slope descriptor (α). Uniaxial tensile testing provided independent Young's modulus measurements.

Results: Increasing stenosis altered pressure magnitude while characteristic loop patterns remained recognizable across conditions, with severe stenosis modifying specific features without eliminating broader patterns. Silicone models showed broad loops, latex models displayed complex crossing patterns, and vascular grafts exhibited narrow, near-linear loops. Loop morphology and the repeatable slope descriptor (α) were consistent across measurements, together differentiating the integrated, configuration-specific dynamic responses of the tested vascular models and grafts.

Conclusion: Pressure-pressure loop analysis provides a novel pressure-only framework for functional characterization of vascular models and grafts. Combining qualitative loop morphology with a reproducible quantitative slope descriptor, the approach captures complementary features of the integrated dynamic pressure response rather than a single intrinsic material property. The study demonstrates the feasibility of extracting meaningful descriptors from two intraluminal pressure waveforms in-vitro, supporting future validation in native blood vessels and applications in vascular graft design.

压力-压力回路:血管生物物理表征的新方法。
目的:通过捕获合成血管模型和血管移植物的综合动态响应及其与狭窄严重程度的相互作用,开发和评估一种仅限压力的方法,用于局部功能表征。方法:体外闭环脉冲血流系统测试7种血管模型和移植物(硅胶,乳胶,ePTFE,涤纶)在0%,50%和90%管腔狭窄。两个近端高保真压力传感器记录腔内压力波形以构建压力-压力回路。通过循环形态定性评价循环行为,并使用斜率描述符(α)定量评价循环行为。单轴拉伸测试提供了独立的杨氏模量测量。结果:狭窄程度的增加改变了压力大小,而不同条件下的特征环路模式仍然可以识别,严重的狭窄改变了特定的特征,但没有消除更广泛的模式。硅胶模型显示出宽的环,乳胶模型显示出复杂的交叉图案,而血管移植物显示出狭窄的、近似线性的环。环路形态和可重复斜率描述符(α)在测量中是一致的,共同区分了被测血管模型和移植物的整体、构型特定的动态响应。结论:压力-压力环分析为血管模型和移植物的功能表征提供了一种新的仅压力的框架。该方法将定性环形态与可重复的定量斜率描述符相结合,捕捉了综合动压响应的互补特征,而不是单一的固有材料特性。该研究证明了从体外两种腔内压力波形中提取有意义描述符的可行性,支持未来在天然血管中的验证和血管移植设计中的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of Biomedical Engineering
Annals of Biomedical Engineering 工程技术-工程:生物医学
CiteScore
7.50
自引率
15.80%
发文量
212
审稿时长
3 months
期刊介绍: Annals of Biomedical Engineering is an official journal of the Biomedical Engineering Society, publishing original articles in the major fields of bioengineering and biomedical engineering. The Annals is an interdisciplinary and international journal with the aim to highlight integrated approaches to the solutions of biological and biomedical problems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书