Effect of implantable collamer lens on biometric measurements and intraocular lens power calculation formulas.

IF 3 3区 医学 Q1 OPHTHALMOLOGY
Wan-Ping Zhang, Yong-Zheng Qu, An-Peng Pan, An-Song Li, Jing-Feng Zhao, Zi-Yue Li, Lin-Hua Chen, Jun Hu, A-Yong Yu
{"title":"Effect of implantable collamer lens on biometric measurements and intraocular lens power calculation formulas.","authors":"Wan-Ping Zhang, Yong-Zheng Qu, An-Peng Pan, An-Song Li, Jing-Feng Zhao, Zi-Yue Li, Lin-Hua Chen, Jun Hu, A-Yong Yu","doi":"10.1111/aos.70259","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the effect of the implantable collamer lens (ICL) on biometric measurements and intraocular lens (IOL) power calculation formulas.</p><p><strong>Methods: </strong>This prospective theoretical study included 92 eyes undergoing ICL surgery. Preoperative and 1-year postoperative biometric parameters, including axial length (AL), keratometry (K), anterior-chamber depth (ACD), lens thickness (LT), central corneal thickness (CCT) and corneal diameter (CD), were measured using IOLMaster 700. Nine formula types (10 variants) were evaluated: Barrett Universal II (BU II; BU II<sup>a</sup>, IOLMaster 700-based; BU II<sup>b</sup>, online calculator), Cooke K6, EVO, Hill-RBF, Hoffer QST, Holladay 1, Kane, Pearl-DGS and SRK/T. Primary outcomes were the difference in predicted spherical equivalent before and after ICL implantation (Δ-pSEQ) and the percentage of eyes within specified Δ-pSEQ ranges.</p><p><strong>Results: </strong>For all eyes (n = 92), significant post-ICL changes included increased AL, steep K (K2), LT, CCT (+0.02 mm, +0.08 D, +0.26 mm, +0.003 mm; p = 0.031, 0.021, <0.001, 0.008) and decreased ACD (-0.28 mm, p < 0.001). ACD segmentation errors occurred in 34.78% of eyes, associated with low vault (optimal cut-off, 0.491 mm; AUC = 0.921). Eyes were grouped by segmentation accuracy (correct, n = 60; incorrect, n = 32). All Δ-pSEQ values were within ±0.50 D; between-subgroup differences in Δ-pSEQ ranges were not significant (p > 0.05). The highest proportions within ±0.25 D were SRK/T (86% overall, 94% incorrect group) and BU II<sup>a</sup> (85% correct group); EVO had the lowest (71%-72%).</p><p><strong>Conclusion: </strong>ICL implantation alters biometric measurements and theoretically predicted Δ-pSEQ; although these changes are statistically significant, their clinical significance is negligible. While incorrect ACD segmentation is common, it is unlikely to substantially affect the theoretical calculation results.</p>","PeriodicalId":6915,"journal":{"name":"Acta Ophthalmologica","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2026-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/aos.70259","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To investigate the effect of the implantable collamer lens (ICL) on biometric measurements and intraocular lens (IOL) power calculation formulas.

Methods: This prospective theoretical study included 92 eyes undergoing ICL surgery. Preoperative and 1-year postoperative biometric parameters, including axial length (AL), keratometry (K), anterior-chamber depth (ACD), lens thickness (LT), central corneal thickness (CCT) and corneal diameter (CD), were measured using IOLMaster 700. Nine formula types (10 variants) were evaluated: Barrett Universal II (BU II; BU IIa, IOLMaster 700-based; BU IIb, online calculator), Cooke K6, EVO, Hill-RBF, Hoffer QST, Holladay 1, Kane, Pearl-DGS and SRK/T. Primary outcomes were the difference in predicted spherical equivalent before and after ICL implantation (Δ-pSEQ) and the percentage of eyes within specified Δ-pSEQ ranges.

Results: For all eyes (n = 92), significant post-ICL changes included increased AL, steep K (K2), LT, CCT (+0.02 mm, +0.08 D, +0.26 mm, +0.003 mm; p = 0.031, 0.021, <0.001, 0.008) and decreased ACD (-0.28 mm, p < 0.001). ACD segmentation errors occurred in 34.78% of eyes, associated with low vault (optimal cut-off, 0.491 mm; AUC = 0.921). Eyes were grouped by segmentation accuracy (correct, n = 60; incorrect, n = 32). All Δ-pSEQ values were within ±0.50 D; between-subgroup differences in Δ-pSEQ ranges were not significant (p > 0.05). The highest proportions within ±0.25 D were SRK/T (86% overall, 94% incorrect group) and BU IIa (85% correct group); EVO had the lowest (71%-72%).

Conclusion: ICL implantation alters biometric measurements and theoretically predicted Δ-pSEQ; although these changes are statistically significant, their clinical significance is negligible. While incorrect ACD segmentation is common, it is unlikely to substantially affect the theoretical calculation results.

植入式collamer透镜对生物的影响测量和人工晶状体功率计算公式。
目的:探讨人工晶状体(ICL)对生物特征测量和人工晶状体(IOL)度数计算公式的影响。方法:本前瞻性理论研究纳入92只接受ICL手术的眼。术前和术后1年的生物特征参数,包括眼轴长度(AL)、角膜度数(K)、前房深度(ACD)、晶状体厚度(LT)、角膜中央厚度(CCT)和角膜直径(CD),使用IOLMaster 700进行测量。评估了9种公式类型(10个变体):Barrett Universal II (BU II; BU IIa,基于IOLMaster 700的;BU IIb,在线计算器),Cooke K6, EVO, Hill-RBF, Hoffer QST, Holladay 1, Kane, Pearl-DGS和SRK/T。主要结果是ICL植入前后预测的球形当量的差异(Δ-pSEQ)和在指定Δ-pSEQ范围内的眼睛百分比。结果:所有眼(n = 92)的icl术后显著改变包括AL升高、K (K2)陡、LT、CCT (+0.02 mm、+0.08 D、+0.26 mm、+0.003 mm; p = 0.031、0.021、0.05)。在±0.25 D范围内比例最高的是SRK/T(总体86%,错误组94%)和BU IIa(正确组85%);EVO最低(71%-72%)。结论:ICL植入改变了生物特征测量值,理论预测Δ-pSEQ;虽然这些变化具有统计学意义,但其临床意义可以忽略不计。虽然错误的ACD分割是常见的,但不太可能实质性地影响理论计算结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta Ophthalmologica
Acta Ophthalmologica 医学-眼科学
CiteScore
7.60
自引率
5.90%
发文量
433
审稿时长
6 months
期刊介绍: Acta Ophthalmologica is published on behalf of the Acta Ophthalmologica Scandinavica Foundation and is the official scientific publication of the following societies: The Danish Ophthalmological Society, The Finnish Ophthalmological Society, The Icelandic Ophthalmological Society, The Norwegian Ophthalmological Society and The Swedish Ophthalmological Society, and also the European Association for Vision and Eye Research (EVER). Acta Ophthalmologica publishes clinical and experimental original articles, reviews, editorials, educational photo essays (Diagnosis and Therapy in Ophthalmology), case reports and case series, letters to the editor and doctoral theses.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书