{"title":"In Situ Growth of MXene (Ti3C2TX) Self-reducing Platinum Particles on Carbon Nanotube Yarns for Skin-Fitting Flexible Strain Sensors","authors":"Shen Hu, Jinlin Xie, Boxuan Zhang, Weiye Wang, Xuqin Ran, Ming Yang, Xinyu Li, Osama Kobesy, Guoke Wei, Hua Qiu, Peng Gu","doi":"10.1007/s12221-026-01567-6","DOIUrl":null,"url":null,"abstract":"<div><p>The rapid development of smart wearable technology has driven innovation in the field of flexible strain sensors. Carbon nanotube (CNT) fibers have emerged as promising candidates for the fabrication of flexible strain sensors due to their exceptional flexibility, remarkably high specific surface area, outstanding mechanical properties, and excellent electrical conductivity. However, interstitial voids between CNT bundles constitute structural defects that impair both load-bearing capacity and electron transport efficiency. This limitation can be effectively mitigated by incorporating metal nanoparticles, which not only fill these voids but also enhance composite performance through their intrinsic low electrical resistance and exceptional chemical inertness. In this study, MXene was utilized as a reducing agent to directly reduce platinum particles from chloroplatinic acid and autonomously grow into the voids of carbon nanotube yarns without the need for additional reducing agents. This modification strategy resulted in substantial enhancements in both mechanical and electrical properties: The tensile strength of platinum-modified CNT yarns increased from 121.2 to 137.27 MPa (13.3% increase), while electrical conductivity demonstrated an 85.3% improvement from 6.18×10<sup>4</sup> S/m to 11.45×10<sup>4</sup> S/m. The prepared flexible and stretchable strain sensors exhibit a resistive change of 380%, a tensile strain range of 0–30%, a GF sensitivity of 23.8, a fast response time of 0.6 s, a recovery time of 0.8 s, and dynamic sensing stability under varying conditions. Significantly, the sensor enables multi-channel synchronous monitoring of biomechanical signals at major human joints, establishing a new design framework for CNT yarn-based elastic strain sensors.</p></div>","PeriodicalId":557,"journal":{"name":"Fibers and Polymers","volume":"27 11","pages":"5705 - 5718"},"PeriodicalIF":3.1000,"publicationDate":"2026-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fibers and Polymers","FirstCategoryId":"88","ListUrlMain":"https://link.springer.com/article/10.1007/s12221-026-01567-6","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, TEXTILES","Score":null,"Total":0}
引用次数: 0
Abstract
The rapid development of smart wearable technology has driven innovation in the field of flexible strain sensors. Carbon nanotube (CNT) fibers have emerged as promising candidates for the fabrication of flexible strain sensors due to their exceptional flexibility, remarkably high specific surface area, outstanding mechanical properties, and excellent electrical conductivity. However, interstitial voids between CNT bundles constitute structural defects that impair both load-bearing capacity and electron transport efficiency. This limitation can be effectively mitigated by incorporating metal nanoparticles, which not only fill these voids but also enhance composite performance through their intrinsic low electrical resistance and exceptional chemical inertness. In this study, MXene was utilized as a reducing agent to directly reduce platinum particles from chloroplatinic acid and autonomously grow into the voids of carbon nanotube yarns without the need for additional reducing agents. This modification strategy resulted in substantial enhancements in both mechanical and electrical properties: The tensile strength of platinum-modified CNT yarns increased from 121.2 to 137.27 MPa (13.3% increase), while electrical conductivity demonstrated an 85.3% improvement from 6.18×104 S/m to 11.45×104 S/m. The prepared flexible and stretchable strain sensors exhibit a resistive change of 380%, a tensile strain range of 0–30%, a GF sensitivity of 23.8, a fast response time of 0.6 s, a recovery time of 0.8 s, and dynamic sensing stability under varying conditions. Significantly, the sensor enables multi-channel synchronous monitoring of biomechanical signals at major human joints, establishing a new design framework for CNT yarn-based elastic strain sensors.
期刊介绍:
-Chemistry of Fiber Materials, Polymer Reactions and Synthesis-
Physical Properties of Fibers, Polymer Blends and Composites-
Fiber Spinning and Textile Processing, Polymer Physics, Morphology-
Colorants and Dyeing, Polymer Analysis and Characterization-
Chemical Aftertreatment of Textiles, Polymer Processing and Rheology-
Textile and Apparel Science, Functional Polymers