N-Type SnO2-Based Trace-Level Fe(III) Ion Sensor for Drinking Water Quality Monitoring

IF 4.5 2区 综合性期刊 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
IEEE Sensors Journal Pub Date : 2026-10-15 Epub Date: 2026-09-07 DOI:10.1109/JSEN.2026.3729478
Sanjay Singh;Sampurna Mukherjee;Sayan Dey
{"title":"N-Type SnO2-Based Trace-Level Fe(III) Ion Sensor for Drinking Water Quality Monitoring","authors":"Sanjay Singh;Sampurna Mukherjee;Sayan Dey","doi":"10.1109/JSEN.2026.3729478","DOIUrl":null,"url":null,"abstract":"Iron(III) contamination in potable water systems represents a critical environmental and public health concern due to its widespread prevalence and associated toxicity. This study details the development of a highly efficient, cost-effective conductometric sensor based on nanostructured n-type <inline-formula> <tex-math>$\\text {SnO}_{{2}}$ </tex-math></inline-formula> for rapid, trace-level quantification of Fe(III) ions in aqueous environments. The fabricated device exhibits exceptional analytical performance, achieving a peak current response ratio (<inline-formula> <tex-math>$\\text {I}_{\\text {Fe(III)}}/\\text {I}_{\\text {Bare}}$ </tex-math></inline-formula>) of approximately 403 at a 10-ppm Fe(III) concentration, alongside an ultralow limit of detection (LOD) of 0.001 ppm experimentally. Furthermore, the sensor demonstrates rapid dynamic kinetics, characterized by response and recovery times of 4.82 and 12.01 s, respectively. It also maintains robust long-term stability over a 31-day period with a marginal performance deviation of <inline-formula> <tex-math>$\\pm {2}.{23}\\%$ </tex-math></inline-formula>. The platform exhibits stringent selectivity for Fe(III) against a background of ubiquitous interfering ions typical of drinking water, combined with outstanding device-to-device reproducibility, attributed to surface adsorption-desorption, yielding a maximum error of only 0.891%. Mechanistically, the enhanced sensing paradigm is attributed to a surface adsorption–desorption process. This phenomenon is governed by exponential defect-induced injection and depletion of charge carriers, which are fundamentally facilitated by abundant oxygen vacancies within the <inline-formula> <tex-math>$\\text {SnO}_{{2}}$ </tex-math></inline-formula> lattice. In summary, the integration of profound sensitivity, rapid response kinetics, strict reproducibility, and extended operational stability positions this <inline-formula> <tex-math>$\\text {SnO}_{{2}}$ </tex-math></inline-formula>-based chemiresistive platform as a highly viable architecture for the real-time, continuous monitoring of iron pollutants in aquatic ecosystems and water infrastructure.","PeriodicalId":447,"journal":{"name":"IEEE Sensors Journal","volume":"26 20","pages":"30094-30098"},"PeriodicalIF":4.5000,"publicationDate":"2026-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors Journal","FirstCategoryId":"103","ListUrlMain":"https://ieeexplore.ieee.org/document/11683307/","RegionNum":2,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/7 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Iron(III) contamination in potable water systems represents a critical environmental and public health concern due to its widespread prevalence and associated toxicity. This study details the development of a highly efficient, cost-effective conductometric sensor based on nanostructured n-type $\text {SnO}_{{2}}$ for rapid, trace-level quantification of Fe(III) ions in aqueous environments. The fabricated device exhibits exceptional analytical performance, achieving a peak current response ratio ( $\text {I}_{\text {Fe(III)}}/\text {I}_{\text {Bare}}$ ) of approximately 403 at a 10-ppm Fe(III) concentration, alongside an ultralow limit of detection (LOD) of 0.001 ppm experimentally. Furthermore, the sensor demonstrates rapid dynamic kinetics, characterized by response and recovery times of 4.82 and 12.01 s, respectively. It also maintains robust long-term stability over a 31-day period with a marginal performance deviation of $\pm {2}.{23}\%$ . The platform exhibits stringent selectivity for Fe(III) against a background of ubiquitous interfering ions typical of drinking water, combined with outstanding device-to-device reproducibility, attributed to surface adsorption-desorption, yielding a maximum error of only 0.891%. Mechanistically, the enhanced sensing paradigm is attributed to a surface adsorption–desorption process. This phenomenon is governed by exponential defect-induced injection and depletion of charge carriers, which are fundamentally facilitated by abundant oxygen vacancies within the $\text {SnO}_{{2}}$ lattice. In summary, the integration of profound sensitivity, rapid response kinetics, strict reproducibility, and extended operational stability positions this $\text {SnO}_{{2}}$ -based chemiresistive platform as a highly viable architecture for the real-time, continuous monitoring of iron pollutants in aquatic ecosystems and water infrastructure.
用于饮用水水质监测的n型sno2型痕量铁离子传感器
饮用水系统中的铁(III)污染由于其广泛流行和相关毒性,是一个严重的环境和公共卫生问题。本研究详细介绍了一种基于纳米结构n型的高效、经济的电导传感器的开发,用于快速、痕量地定量水环境中的Fe(III)离子。该装置具有优异的分析性能,在10 ppm Fe(III)浓度下,峰值电流响应比($\text {I}_{\text {Fe(III)}}/\text {I}_{\text {Bare}}$)约为403,同时实验的超低检测限(LOD)为0.001 ppm。该传感器具有快速的动态动力学特性,响应时间为4.82 s,恢复时间为12.01 s。在31天的时间内,它还保持了强劲的长期稳定性,边际性能偏差为100亿美元。{23} \ % $。该平台在饮用水中普遍存在的干扰离子背景下,对Fe(III)具有严格的选择性,并且由于表面吸附-解吸,具有出色的设备间再现性,最大误差仅为0.891%。从机理上讲,增强的传感模式归因于表面吸附-解吸过程。这一现象是由指数缺陷引起的载流子注入和耗尽控制的,而这主要是由$\text {SnO}_{{2}}$晶格内丰富的氧空位促进的。综上所述,该平台具有高度的灵敏度、快速的响应动力学、严格的重现性和扩展的操作稳定性,使其成为水生生态系统和水基础设施中铁污染物实时、连续监测的高度可行的架构。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Sensors Journal
IEEE Sensors Journal 工程技术-工程:电子与电气
CiteScore
7.70
自引率
14.00%
发文量
2058
审稿时长
5.2 months
期刊介绍: The fields of interest of the IEEE Sensors Journal are the theory, design , fabrication, manufacturing and applications of devices for sensing and transducing physical, chemical and biological phenomena, with emphasis on the electronics and physics aspect of sensors and integrated sensors-actuators. IEEE Sensors Journal deals with the following: -Sensor Phenomenology, Modelling, and Evaluation -Sensor Materials, Processing, and Fabrication -Chemical and Gas Sensors -Microfluidics and Biosensors -Optical Sensors -Physical Sensors: Temperature, Mechanical, Magnetic, and others -Acoustic and Ultrasonic Sensors -Sensor Packaging -Sensor Networks -Sensor Applications -Sensor Systems: Signals, Processing, and Interfaces -Actuators and Sensor Power Systems -Sensor Signal Processing for high precision and stability (amplification, filtering, linearization, modulation/demodulation) and under harsh conditions (EMC, radiation, humidity, temperature); energy consumption/harvesting -Sensor Data Processing (soft computing with sensor data, e.g., pattern recognition, machine learning, evolutionary computation; sensor data fusion, processing of wave e.g., electromagnetic and acoustic; and non-wave, e.g., chemical, gravity, particle, thermal, radiative and non-radiative sensor data, detection, estimation and classification based on sensor data) -Sensors in Industrial Practice
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书