Elham Alaei;Syed Ali Raza Bukhari;Tanzila Afrin;Laura Wells;Robert Campbell;Yongjun Lai
{"title":"A Microfluidic Contact Lens With Optimized Channel Placement for Enhanced Sensitivity for Continuous Intraocular Pressure Monitoring","authors":"Elham Alaei;Syed Ali Raza Bukhari;Tanzila Afrin;Laura Wells;Robert Campbell;Yongjun Lai","doi":"10.1109/JSEN.2026.3730668","DOIUrl":null,"url":null,"abstract":"Monitoring continuous intraocular pressure (IOP) is essential for the diagnosis and management of glaucoma; however, current microfluidic sensing techniques lack design optimization and leave substantial room for improvement. In this study, we present a highly sensitive microfluidic contact lens designed to transform intraocular deformation into measurable fluid displacement. The device incorporates a wide reservoir channel, coupled to a narrow indicator channel, enabling amplified displacement, while an integrated air reservoir improves the overall sensitivity. The lens is fabricated using Ecoflex-0030, a soft and biocompatible elastomer with a low Young’s modulus whose strain responsiveness surpasses conventional polydimethylsiloxane (PDMS)-based microfluidic contact lenses. Experimental evaluations using a synthetic eye model demonstrate the highest displacement sensitivity reported to date for microfluidic contact lens sensors, with consistent performance validated through repeated trials and cyclic pressure testing. To further improve device performance, a comprehensive microchannel-location study was conducted that revealed strongly nonuniform strain distributions across the corneal surface. Four lens designs with varying microchannel locations were fabricated and extensively tested to obtain the ideal location for microchannel placement. The sensitivity characterization revealed substantial variation across the different channel locations, with values of 0.5057,1.032, 0.775, and 0.614 mm/mmHg observed for the designs D6, D7, D8, and D9 (at 6, 7, 8, and 9 mm diameter), respectively. The final optimized layout of D7 produced a superior response, reaching 1.032 mm/mmHg, which surpasses previously reported performance in microfluidic contact lenses. These findings demonstrate the importance of mechanical coupling and structural optimization to obtain a highly sensitive and reliable sensor.","PeriodicalId":447,"journal":{"name":"IEEE Sensors Journal","volume":"26 20","pages":"30229-30237"},"PeriodicalIF":4.5000,"publicationDate":"2026-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors Journal","FirstCategoryId":"103","ListUrlMain":"https://ieeexplore.ieee.org/document/11686200/","RegionNum":2,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/10 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Monitoring continuous intraocular pressure (IOP) is essential for the diagnosis and management of glaucoma; however, current microfluidic sensing techniques lack design optimization and leave substantial room for improvement. In this study, we present a highly sensitive microfluidic contact lens designed to transform intraocular deformation into measurable fluid displacement. The device incorporates a wide reservoir channel, coupled to a narrow indicator channel, enabling amplified displacement, while an integrated air reservoir improves the overall sensitivity. The lens is fabricated using Ecoflex-0030, a soft and biocompatible elastomer with a low Young’s modulus whose strain responsiveness surpasses conventional polydimethylsiloxane (PDMS)-based microfluidic contact lenses. Experimental evaluations using a synthetic eye model demonstrate the highest displacement sensitivity reported to date for microfluidic contact lens sensors, with consistent performance validated through repeated trials and cyclic pressure testing. To further improve device performance, a comprehensive microchannel-location study was conducted that revealed strongly nonuniform strain distributions across the corneal surface. Four lens designs with varying microchannel locations were fabricated and extensively tested to obtain the ideal location for microchannel placement. The sensitivity characterization revealed substantial variation across the different channel locations, with values of 0.5057,1.032, 0.775, and 0.614 mm/mmHg observed for the designs D6, D7, D8, and D9 (at 6, 7, 8, and 9 mm diameter), respectively. The final optimized layout of D7 produced a superior response, reaching 1.032 mm/mmHg, which surpasses previously reported performance in microfluidic contact lenses. These findings demonstrate the importance of mechanical coupling and structural optimization to obtain a highly sensitive and reliable sensor.
期刊介绍:
The fields of interest of the IEEE Sensors Journal are the theory, design , fabrication, manufacturing and applications of devices for sensing and transducing physical, chemical and biological phenomena, with emphasis on the electronics and physics aspect of sensors and integrated sensors-actuators. IEEE Sensors Journal deals with the following:
-Sensor Phenomenology, Modelling, and Evaluation
-Sensor Materials, Processing, and Fabrication
-Chemical and Gas Sensors
-Microfluidics and Biosensors
-Optical Sensors
-Physical Sensors: Temperature, Mechanical, Magnetic, and others
-Acoustic and Ultrasonic Sensors
-Sensor Packaging
-Sensor Networks
-Sensor Applications
-Sensor Systems: Signals, Processing, and Interfaces
-Actuators and Sensor Power Systems
-Sensor Signal Processing for high precision and stability (amplification, filtering, linearization, modulation/demodulation) and under harsh conditions (EMC, radiation, humidity, temperature); energy consumption/harvesting
-Sensor Data Processing (soft computing with sensor data, e.g., pattern recognition, machine learning, evolutionary computation; sensor data fusion, processing of wave e.g., electromagnetic and acoustic; and non-wave, e.g., chemical, gravity, particle, thermal, radiative and non-radiative sensor data, detection, estimation and classification based on sensor data)
-Sensors in Industrial Practice