{"title":"Development of a Property-Guided HS-SPME-GC-MS Method for Broad-Range Qualitative Screening of Potentially Hazardous VOCs in Recycled Polypropylene","authors":"Wei Jiang, Huijun Yi, Caleb Chatfield, Chloe Higdon, Nathan Mancos, Shaoyang Liu","doi":"10.1021/acspolymersau.6c00124","DOIUrl":null,"url":null,"abstract":"<p>The increasing use of recycled plastics has raised concerns\r\nregarding\r\nthe potential emission of hazardous volatile organic compounds (VOCs)\r\nduring recycling and in subsequent applications. However, systematic\r\nanalytical methods for VOC analysis in real recycled plastic materials\r\nremain limited due to the complex and diverse composition of emitted\r\nVOCs. In this study, a qualitative analytical method based on headspace\r\nsolid-phase microextraction coupled with gas chromatography–mass\r\nspectrometry (HS-SPME-GC-MS) was developed for characterizing potentially\r\nhazardous VOCs in recycled polypropylene (rPP). A total of 622 candidate\r\ncontaminants associated with recycled plastics were compiled. After\r\nscreening by NFPA health hazard rating and volatility, 274 potentially\r\nhazardous VOCs were retained, and 27 representative compounds were\r\nselected to cover broad vapor-pressure and polarity ranges. Five SPME\r\nfiber coatings were evaluated, among which DVB/C-WR/PDMS provided\r\nthe broadest detection coverage, detecting 24 of the 27 representative\r\ncompounds. Response surface methodology based on rotatable central\r\ncomposite designs was then used to optimize SPME temperature, incubation\r\ntime, and extraction time. SPME temperature was the dominant factor\r\naffecting extraction efficiency, and that vapor pressure was the primary\r\nphysicochemical determinant of extraction behavior. High- and medium-vapor-pressure\r\nVOCs were most efficiently extracted under relatively moderate-temperature\r\nconditions, with an optimized SPME temperature of 68.7 °C, incubation\r\ntime of 5.5 min, and extraction time of 10.4 min. In contrast, low-vapor-pressure\r\nVOCs required higher temperatures to promote transfer from the polymer\r\nmatrix to the headspace, and 110 °C was identified as a practical\r\ncompromise. Using the optimized method, aliphatic hydrocarbons, aromatic\r\nhydrocarbons, oxygenated compounds, and lindane were detected in industrial\r\nrPP samples, indicating multiple potential contamination sources in\r\nrecycled plastic streams. This study provides a systematic HS-SPME-GC-MS\r\nstrategy for broad qualitative screening of potentially hazardous\r\nVOCs in rPP and may support quality control, emission assessment,\r\nand process optimization in plastic recycling.</p>","PeriodicalId":72049,"journal":{"name":"ACS polymers Au","volume":"6 5","pages":"1422–1434"},"PeriodicalIF":6.7000,"publicationDate":"2026-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS polymers Au","FirstCategoryId":"1085","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acspolymersau.6c00124","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/24 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"POLYMER SCIENCE","Score":null,"Total":0}
引用次数: 0
Abstract
The increasing use of recycled plastics has raised concerns
regarding
the potential emission of hazardous volatile organic compounds (VOCs)
during recycling and in subsequent applications. However, systematic
analytical methods for VOC analysis in real recycled plastic materials
remain limited due to the complex and diverse composition of emitted
VOCs. In this study, a qualitative analytical method based on headspace
solid-phase microextraction coupled with gas chromatography–mass
spectrometry (HS-SPME-GC-MS) was developed for characterizing potentially
hazardous VOCs in recycled polypropylene (rPP). A total of 622 candidate
contaminants associated with recycled plastics were compiled. After
screening by NFPA health hazard rating and volatility, 274 potentially
hazardous VOCs were retained, and 27 representative compounds were
selected to cover broad vapor-pressure and polarity ranges. Five SPME
fiber coatings were evaluated, among which DVB/C-WR/PDMS provided
the broadest detection coverage, detecting 24 of the 27 representative
compounds. Response surface methodology based on rotatable central
composite designs was then used to optimize SPME temperature, incubation
time, and extraction time. SPME temperature was the dominant factor
affecting extraction efficiency, and that vapor pressure was the primary
physicochemical determinant of extraction behavior. High- and medium-vapor-pressure
VOCs were most efficiently extracted under relatively moderate-temperature
conditions, with an optimized SPME temperature of 68.7 °C, incubation
time of 5.5 min, and extraction time of 10.4 min. In contrast, low-vapor-pressure
VOCs required higher temperatures to promote transfer from the polymer
matrix to the headspace, and 110 °C was identified as a practical
compromise. Using the optimized method, aliphatic hydrocarbons, aromatic
hydrocarbons, oxygenated compounds, and lindane were detected in industrial
rPP samples, indicating multiple potential contamination sources in
recycled plastic streams. This study provides a systematic HS-SPME-GC-MS
strategy for broad qualitative screening of potentially hazardous
VOCs in rPP and may support quality control, emission assessment,
and process optimization in plastic recycling.