Comparative Diagnostic Performance of Three Commercial Real-Time PCR Assays for the Detection of Mycobacterium tuberculosis Complex in Bronchial Washing Specimens: A Large Retrospective Study.

IF 2.5 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY
Jimyung Kim, Yumi Park
{"title":"Comparative Diagnostic Performance of Three Commercial Real-Time PCR Assays for the Detection of Mycobacterium tuberculosis Complex in Bronchial Washing Specimens: A Large Retrospective Study.","authors":"Jimyung Kim, Yumi Park","doi":"10.1002/jcla.70380","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Molecular assays are essential for the rapid detection of Mycobacterium tuberculosis complex (MTBC). However, head-to-head comparisons of widely used commercial assays remain limited. This study compared the diagnostic performance of three real-time PCR assays-AdvanSure TB/NTM, Cobas MTB, and Xpert MTB/RIF-using bronchial washing specimens.</p><p><strong>Methods: </strong>We retrospectively analyzed molecular assay results from 3348 bronchial washing specimens obtained between January 2021 and May 2024. Among them, 740 specimens were included in a head-to-head comparison of the three assays. Diagnostic performance was evaluated using culture-confirmed MTBC as the reference standard.</p><p><strong>Results: </strong>In the head-to-head comparison (n = 740), the overall concordance rate was 93.6%. Using culture-confirmed MTBC as the reference standard, the sensitivities of the AdvanSure, Cobas, and Xpert assays were 49.1%, 96.2%, and 90.6%, respectively. In smear-negative cases (n = 713), AdvanSure showed markedly lower sensitivity (30.8%) than the Cobas (94.9%) and Xpert (87.2%). AdvanSure showed the highest overall specificity (98.7%), followed by Cobas (96.9%) and Xpert (96.4%). The Xpert MTB/RIF assay demonstrated complete concordance with drug susceptibility testing for detecting rifampicin resistance, with a sensitivity of 100% (95% CI, 59.0%-100.0%) and a specificity of 100% (95% CI, 97.3%-100.0%).</p><p><strong>Conclusion: </strong>In this real-world cohort with a high proportion of smear-negative cases, the Cobas and Xpert assays exhibited significantly higher sensitivity for MTBC detection than the AdvanSure assay. These findings highlight the importance of highly sensitive molecular assays for the early diagnosis of pulmonary tuberculosis, particularly in patients with low bacillary burden.</p>","PeriodicalId":15509,"journal":{"name":"Journal of Clinical Laboratory Analysis","volume":" ","pages":"e70380"},"PeriodicalIF":2.5000,"publicationDate":"2026-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13656069/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Laboratory Analysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jcla.70380","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Molecular assays are essential for the rapid detection of Mycobacterium tuberculosis complex (MTBC). However, head-to-head comparisons of widely used commercial assays remain limited. This study compared the diagnostic performance of three real-time PCR assays-AdvanSure TB/NTM, Cobas MTB, and Xpert MTB/RIF-using bronchial washing specimens.

Methods: We retrospectively analyzed molecular assay results from 3348 bronchial washing specimens obtained between January 2021 and May 2024. Among them, 740 specimens were included in a head-to-head comparison of the three assays. Diagnostic performance was evaluated using culture-confirmed MTBC as the reference standard.

Results: In the head-to-head comparison (n = 740), the overall concordance rate was 93.6%. Using culture-confirmed MTBC as the reference standard, the sensitivities of the AdvanSure, Cobas, and Xpert assays were 49.1%, 96.2%, and 90.6%, respectively. In smear-negative cases (n = 713), AdvanSure showed markedly lower sensitivity (30.8%) than the Cobas (94.9%) and Xpert (87.2%). AdvanSure showed the highest overall specificity (98.7%), followed by Cobas (96.9%) and Xpert (96.4%). The Xpert MTB/RIF assay demonstrated complete concordance with drug susceptibility testing for detecting rifampicin resistance, with a sensitivity of 100% (95% CI, 59.0%-100.0%) and a specificity of 100% (95% CI, 97.3%-100.0%).

Conclusion: In this real-world cohort with a high proportion of smear-negative cases, the Cobas and Xpert assays exhibited significantly higher sensitivity for MTBC detection than the AdvanSure assay. These findings highlight the importance of highly sensitive molecular assays for the early diagnosis of pulmonary tuberculosis, particularly in patients with low bacillary burden.

三种商用实时荧光定量PCR检测支气管洗涤标本中结核分枝杆菌复合体的比较诊断性能:一项大型回顾性研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Clinical Laboratory Analysis
Journal of Clinical Laboratory Analysis 医学-医学实验技术
CiteScore
5.60
自引率
7.40%
发文量
584
审稿时长
6-12 weeks
期刊介绍: Journal of Clinical Laboratory Analysis publishes original articles on newly developing modes of technology and laboratory assays, with emphasis on their application in current and future clinical laboratory testing. This includes reports from the following fields: immunochemistry and toxicology, hematology and hematopathology, immunopathology, molecular diagnostics, microbiology, genetic testing, immunohematology, and clinical chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书