Use of the Guardian table extension during periacetabular osteotomy is associated with an increased risk of intraoperative posterior column fractures.

IF 1.6 4区 医学 Q3 ORTHOPEDICS
Journal of Hip Preservation Surgery Pub Date : 2025-10-17 eCollection Date: 2026-08-01 DOI:10.1093/jhps/hnaf062
Ta-Wei Tai, Emil Varas-Rodríguez, Emmanouil Grigoriou, Sergio F Guarin Perez, Diego J Restrepo, Rafael J Sierra
{"title":"Use of the Guardian table extension during periacetabular osteotomy is associated with an increased risk of intraoperative posterior column fractures.","authors":"Ta-Wei Tai, Emil Varas-Rodríguez, Emmanouil Grigoriou, Sergio F Guarin Perez, Diego J Restrepo, Rafael J Sierra","doi":"10.1093/jhps/hnaf062","DOIUrl":null,"url":null,"abstract":"<p><p>The Guardian table is widely utilized for combined hip arthroscopy and periacetabular osteotomy (PAO) due to its postless traction design and the ability to perform both procedures without the need for redraping. This retrospective cohort study reports one surgeon's use of the Guardian table extension during combined hip arthroscopy and PAO and the occurrence of intraoperative posterior column fractures. Seventy-two consecutive PAO procedures performed at a single institution between February 2023 and January 2025 were analysed. Procedures involving concomitant hip arthroscopy (<i>n</i> = 26) utilized the Guardian table, whereas those without arthroscopy (<i>n</i> = 46) used a conventional radiolucent table. Patient demographics, clinical data, and complications were reviewed. Additionally, mechanical testing quantified table stability by measuring peak absolute acceleration ('table bounce') using accelerometry during simulated malleting. The incidence of intraoperative posterior column fractures was significantly higher with the Guardian table (4/26, 15.4%) compared to the conventional table (0/46, 0%; <i>P</i> = .0062). Mechanical testing demonstrated significantly greater table bounce for the Guardian table (69.1 ± 3.4 m/s<sup>2</sup> versus 28.2 ± 4.4 m/s<sup>2</sup>, <i>P</i> < .001). Patient characteristics and surgical complexity did not differ significantly between fracture and non-fracture cases. These findings suggested that the Guardian table extension system was associated with increased risk of posterior column fractures, likely due to lack of distal support and stability. Surgeons should consider alternative table setups or intraoperative support modifications to mitigate this risk during PAO procedures.</p>","PeriodicalId":48583,"journal":{"name":"Journal of Hip Preservation Surgery","volume":"13 3","pages":"225-230"},"PeriodicalIF":1.6000,"publicationDate":"2025-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13653056/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hip Preservation Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jhps/hnaf062","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

The Guardian table is widely utilized for combined hip arthroscopy and periacetabular osteotomy (PAO) due to its postless traction design and the ability to perform both procedures without the need for redraping. This retrospective cohort study reports one surgeon's use of the Guardian table extension during combined hip arthroscopy and PAO and the occurrence of intraoperative posterior column fractures. Seventy-two consecutive PAO procedures performed at a single institution between February 2023 and January 2025 were analysed. Procedures involving concomitant hip arthroscopy (n = 26) utilized the Guardian table, whereas those without arthroscopy (n = 46) used a conventional radiolucent table. Patient demographics, clinical data, and complications were reviewed. Additionally, mechanical testing quantified table stability by measuring peak absolute acceleration ('table bounce') using accelerometry during simulated malleting. The incidence of intraoperative posterior column fractures was significantly higher with the Guardian table (4/26, 15.4%) compared to the conventional table (0/46, 0%; P = .0062). Mechanical testing demonstrated significantly greater table bounce for the Guardian table (69.1 ± 3.4 m/s2 versus 28.2 ± 4.4 m/s2, P < .001). Patient characteristics and surgical complexity did not differ significantly between fracture and non-fracture cases. These findings suggested that the Guardian table extension system was associated with increased risk of posterior column fractures, likely due to lack of distal support and stability. Surgeons should consider alternative table setups or intraoperative support modifications to mitigate this risk during PAO procedures.

在髋臼周围截骨术中使用Guardian table扩展与术中后柱骨折的风险增加相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
20.00%
发文量
45
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书