Improved Visualization of Heart Valves With 4D-CT Using a Novel Motion Correction Algorithm.

IF 7.9 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Daniel Zedler, Tristan T Demmert, André Ritter, Thomas Allmendinger, Bernhard Schmidt, Albert M Kasel, Omer Dzemali, Robert Manka, Victor Mergen, Thomas Flohr, Matthias Eberhard, Hatem Alkadhi
{"title":"Improved Visualization of Heart Valves With 4D-CT Using a Novel Motion Correction Algorithm.","authors":"Daniel Zedler, Tristan T Demmert, André Ritter, Thomas Allmendinger, Bernhard Schmidt, Albert M Kasel, Omer Dzemali, Robert Manka, Victor Mergen, Thomas Flohr, Matthias Eberhard, Hatem Alkadhi","doi":"10.1097/RLI.0000000000001310","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Motion artifacts remain a limitation of cardiac CT when assessing both native and prosthetic heart valves, particularly during phases of rapid motion. This may lead to reduced image quality, potentially impairing the evaluation of valvular movement and pathology. The purpose of this study was to evaluate whether a novel reconstruction-based motion correction algorithm improves image quality and reduces motion artifacts of native and prosthetic heart valves compared with standard reconstructions in photon-counting detector CT (PCD-CT).</p><p><strong>Materials and methods: </strong>In this retrospective single-center study, 57 patients [21 women; median age, 71 (interquartile range, 57 to 78 y)] who underwent clinically indicated 4D cardiac CT for suspected native and prosthetic valvular disease were included. Images were acquired using retrospectively electrocardiography (ECG)-gated spiral dual-source PCD-CT without ECG-pulsing. Images were reconstructed in 10% steps throughout the RR-interval using both standard (TrueStack) and an otherwise identical reconstruction using the novel motion correction algorithm (ZeeFreePlus). Subjective image quality and motion artifacts were independently assessed by 2 blinded, experienced readers using a 4-point visual analog scale for 3 categories: valve frame/annulus, valve leaflets, and valvular pathology. Objective analysis included quantification of the volume of artifacts throughout the cardiac cycle.</p><p><strong>Results: </strong>A total of 68 valves were evaluated, including 57 prosthetic valves (22 transcatheter aortic valve replacements and 19 surgical valves, 11 mitral valves, and 5 tricuspid valve interventions) and 11 native valves. Valvular pathology was present in 29 cases, with the most prevalent being hypoattenuated leaflet thickening in 14/29 (48%). Motion-corrected reconstructions significantly improved image quality and reduced motion artifacts across all cardiac phases and all categories (all, P<0.001). The largest improvements were observed during systole, particularly at 10% of the RR-interval, with significantly greater gains than during diastole (P<0.05). Improvements were consistent across aortic and atrioventricular prosthetic valves and translated into improved visualization of valvular pathology (P<0.001). Objective quantitative analysis corroborated the subjective image quality findings by demonstrating reductions in the volumes of motion-induced artifacts when using the algorithm (P<0.001).</p><p><strong>Conclusions: </strong>A novel motion correction algorithm substantially reduced motion artifacts and improved image quality in both native and prosthetic heart valve imaging with PCD-CT, with the largest improvements in systole. These benefits resulted in enhanced visualization of valvular pathology, potentially reinforcing the growing clinical role of cardiac CT for the assessment of valve disease.</p>","PeriodicalId":14486,"journal":{"name":"Investigative Radiology","volume":" ","pages":""},"PeriodicalIF":7.9000,"publicationDate":"2026-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RLI.0000000000001310","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Motion artifacts remain a limitation of cardiac CT when assessing both native and prosthetic heart valves, particularly during phases of rapid motion. This may lead to reduced image quality, potentially impairing the evaluation of valvular movement and pathology. The purpose of this study was to evaluate whether a novel reconstruction-based motion correction algorithm improves image quality and reduces motion artifacts of native and prosthetic heart valves compared with standard reconstructions in photon-counting detector CT (PCD-CT).

Materials and methods: In this retrospective single-center study, 57 patients [21 women; median age, 71 (interquartile range, 57 to 78 y)] who underwent clinically indicated 4D cardiac CT for suspected native and prosthetic valvular disease were included. Images were acquired using retrospectively electrocardiography (ECG)-gated spiral dual-source PCD-CT without ECG-pulsing. Images were reconstructed in 10% steps throughout the RR-interval using both standard (TrueStack) and an otherwise identical reconstruction using the novel motion correction algorithm (ZeeFreePlus). Subjective image quality and motion artifacts were independently assessed by 2 blinded, experienced readers using a 4-point visual analog scale for 3 categories: valve frame/annulus, valve leaflets, and valvular pathology. Objective analysis included quantification of the volume of artifacts throughout the cardiac cycle.

Results: A total of 68 valves were evaluated, including 57 prosthetic valves (22 transcatheter aortic valve replacements and 19 surgical valves, 11 mitral valves, and 5 tricuspid valve interventions) and 11 native valves. Valvular pathology was present in 29 cases, with the most prevalent being hypoattenuated leaflet thickening in 14/29 (48%). Motion-corrected reconstructions significantly improved image quality and reduced motion artifacts across all cardiac phases and all categories (all, P<0.001). The largest improvements were observed during systole, particularly at 10% of the RR-interval, with significantly greater gains than during diastole (P<0.05). Improvements were consistent across aortic and atrioventricular prosthetic valves and translated into improved visualization of valvular pathology (P<0.001). Objective quantitative analysis corroborated the subjective image quality findings by demonstrating reductions in the volumes of motion-induced artifacts when using the algorithm (P<0.001).

Conclusions: A novel motion correction algorithm substantially reduced motion artifacts and improved image quality in both native and prosthetic heart valve imaging with PCD-CT, with the largest improvements in systole. These benefits resulted in enhanced visualization of valvular pathology, potentially reinforcing the growing clinical role of cardiac CT for the assessment of valve disease.

利用一种新的运动校正算法改进4D-CT心脏瓣膜的可视化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Investigative Radiology
Investigative Radiology 医学-核医学
CiteScore
15.10
自引率
16.40%
发文量
188
审稿时长
4-8 weeks
期刊介绍: Investigative Radiology publishes original, peer-reviewed reports on clinical and laboratory investigations in diagnostic imaging, the diagnostic use of radioactive isotopes, computed tomography, positron emission tomography, magnetic resonance imaging, ultrasound, digital subtraction angiography, and related modalities. Emphasis is on early and timely publication. Primarily research-oriented, the journal also includes a wide variety of features of interest to clinical radiologists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书