Comparative study of aperture-induced aberrations in reflective and transmissive optical spectrometers using ZEMAX.

IF 1.5 3区 物理与天体物理 Q3 OPTICS
Muddasir Naeem, Tayyab Imran
{"title":"Comparative study of aperture-induced aberrations in reflective and transmissive optical spectrometers using ZEMAX.","authors":"Muddasir Naeem, Tayyab Imran","doi":"10.1364/JOSAA.604734","DOIUrl":null,"url":null,"abstract":"<p><p>This study presents a design-level comparison of aperture-induced imaging degradation in reflective and transmissive optical spectrometers using ZEMAX OpticStudio. Two representative grating-based spectrometer configurations were modeled and evaluated under identical input-aperture, wavelength, detector, and grating-order conditions while varying the entrance pinhole diameter from 5 to 100 µm. The optical response was assessed using complementary image-quality metrics, including geometric, Huygens, and diffraction modulation transfer functions, line spread function, edge spread function, FFT-derived spread functions, and detector-plane irradiance. The results show that increasing the input pinhole size systematically reduces modulation transfer, broadens the line and edge responses, and redistributes optical energy over a larger detector region, indicating a transition from an optics-limited response at small apertures to a source-size-limited response at larger apertures. Within the specific optical prescriptions considered here, the reflective configuration preserved modulation, edge sharpness, and detector-plane energy confinement more effectively than the simple singlet-lens transmissive configuration. The study establishes a direct design connection between entrance-aperture size, spatial-frequency response, spread-function broadening, and detector-plane energy confinement, providing practical guidance for compact spectrometer designs where resolution, throughput, and aberration tolerance must be balanced.</p>","PeriodicalId":17382,"journal":{"name":"Journal of The Optical Society of America A-optics Image Science and Vision","volume":"43 8","pages":"1272-1283"},"PeriodicalIF":1.5000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Optical Society of America A-optics Image Science and Vision","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1364/JOSAA.604734","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0

Abstract

This study presents a design-level comparison of aperture-induced imaging degradation in reflective and transmissive optical spectrometers using ZEMAX OpticStudio. Two representative grating-based spectrometer configurations were modeled and evaluated under identical input-aperture, wavelength, detector, and grating-order conditions while varying the entrance pinhole diameter from 5 to 100 µm. The optical response was assessed using complementary image-quality metrics, including geometric, Huygens, and diffraction modulation transfer functions, line spread function, edge spread function, FFT-derived spread functions, and detector-plane irradiance. The results show that increasing the input pinhole size systematically reduces modulation transfer, broadens the line and edge responses, and redistributes optical energy over a larger detector region, indicating a transition from an optics-limited response at small apertures to a source-size-limited response at larger apertures. Within the specific optical prescriptions considered here, the reflective configuration preserved modulation, edge sharpness, and detector-plane energy confinement more effectively than the simple singlet-lens transmissive configuration. The study establishes a direct design connection between entrance-aperture size, spatial-frequency response, spread-function broadening, and detector-plane energy confinement, providing practical guidance for compact spectrometer designs where resolution, throughput, and aberration tolerance must be balanced.

利用ZEMAX对反射和透射光谱仪孔径诱导像差的比较研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.40
自引率
10.50%
发文量
417
审稿时长
3 months
期刊介绍: The Journal of the Optical Society of America A (JOSA A) is devoted to developments in any field of classical optics, image science, and vision. JOSA A includes original peer-reviewed papers on such topics as: * Atmospheric optics * Clinical vision * Coherence and Statistical Optics * Color * Diffraction and gratings * Image processing * Machine vision * Physiological optics * Polarization * Scattering * Signal processing * Thin films * Visual optics Also: j opt soc am a.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书