{"title":"Post-market safety signals of energy-based surgical devices: a cross-specialty disproportionality analysis of the FDA MAUDE database with robotic-platform validation and regulatory triangulation, 2015-2025.","authors":"Ruifeng Shi","doi":"10.1007/s11701-026-04060-7","DOIUrl":null,"url":null,"abstract":"<p><p>Post-market safety evidence for energy-based surgical devices is fragmented. We characterized adverse-event signals in the FDA MAUDE database, validated them on a third (robotic) platform, and triangulated across regulatory and international sources. Medical Device Reports (2015-2025) under electrosurgical and ultrasonic product codes were analyzed with reporting odds ratios (RORs), stratified by specialty and procedure, with robustness checks. All reports under the robotic-system code were retrieved as a third-platform validation cohort. Signals were triangulated with FDA recalls, 510(k) clearances, the Health Canada and Australian TGA databases, exposure descriptors, and a retrospectively applied Poisson CUSUM feasibility analysis. Among 110,183 deduplicated reports (65.8% electrosurgical, 34.2% ultrasonic), electrosurgical devices showed an electrical-thermal fingerprint (burns ROR 3.84; electric shock ROR 15.34) and ultrasonic devices a mechanical-integrity fingerprint (foreign-body removal ROR 92.74), replicated directionally in Canada and Australia. The fingerprint localized to generator/monopolar components and varied by specialty and procedure. Within the robotic validation cohort, component-stratified analysis partly reproduced these signatures-robot-mounted monopolar instruments retained a burn signal, and robot-mounted ultrasonic instruments carried the highest injury-report share-while cross-platform, same-modality contrasts are reported strictly as report-composition (share-level) comparisons. Reporting artifacts (19.5% placeholder narratives; a 2025 robotic mass-reporting episode comprising 55.8% of the robotic cohort) left fingerprint RORs materially unchanged. A retrospectively applied CUSUM flagged the burn theme more than five years before the 2023-2024 Class I recalls, illustrating-without establishing prospective lead time-the potential of automated monitoring. Energy-modality failure-injury fingerprints were consistent across specialties, delivery platforms, three national databases, and regulatory actions. Automated, artifact-aware surveillance of vigilance databases is a promising complement to pre-market review and warrants prospective evaluation.</p>","PeriodicalId":47616,"journal":{"name":"Journal of Robotic Surgery","volume":"20 1","pages":""},"PeriodicalIF":4.2000,"publicationDate":"2026-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Robotic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11701-026-04060-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Post-market safety evidence for energy-based surgical devices is fragmented. We characterized adverse-event signals in the FDA MAUDE database, validated them on a third (robotic) platform, and triangulated across regulatory and international sources. Medical Device Reports (2015-2025) under electrosurgical and ultrasonic product codes were analyzed with reporting odds ratios (RORs), stratified by specialty and procedure, with robustness checks. All reports under the robotic-system code were retrieved as a third-platform validation cohort. Signals were triangulated with FDA recalls, 510(k) clearances, the Health Canada and Australian TGA databases, exposure descriptors, and a retrospectively applied Poisson CUSUM feasibility analysis. Among 110,183 deduplicated reports (65.8% electrosurgical, 34.2% ultrasonic), electrosurgical devices showed an electrical-thermal fingerprint (burns ROR 3.84; electric shock ROR 15.34) and ultrasonic devices a mechanical-integrity fingerprint (foreign-body removal ROR 92.74), replicated directionally in Canada and Australia. The fingerprint localized to generator/monopolar components and varied by specialty and procedure. Within the robotic validation cohort, component-stratified analysis partly reproduced these signatures-robot-mounted monopolar instruments retained a burn signal, and robot-mounted ultrasonic instruments carried the highest injury-report share-while cross-platform, same-modality contrasts are reported strictly as report-composition (share-level) comparisons. Reporting artifacts (19.5% placeholder narratives; a 2025 robotic mass-reporting episode comprising 55.8% of the robotic cohort) left fingerprint RORs materially unchanged. A retrospectively applied CUSUM flagged the burn theme more than five years before the 2023-2024 Class I recalls, illustrating-without establishing prospective lead time-the potential of automated monitoring. Energy-modality failure-injury fingerprints were consistent across specialties, delivery platforms, three national databases, and regulatory actions. Automated, artifact-aware surveillance of vigilance databases is a promising complement to pre-market review and warrants prospective evaluation.

基于能量的手术器械上市后安全信号:基于机器人平台验证和监管三角测量的FDA MAUDE数据库的跨专业歧化分析,2015-2025。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.20
自引率
8.70%
发文量
145
期刊介绍: The aim of the Journal of Robotic Surgery is to become the leading worldwide journal for publication of articles related to robotic surgery, encompassing surgical simulation and integrated imaging techniques. The journal provides a centralized, focused resource for physicians wishing to publish their experience or those wishing to avail themselves of the most up-to-date findings.The journal reports on advance in a wide range of surgical specialties including adult and pediatric urology, general surgery, cardiac surgery, gynecology, ENT, orthopedics and neurosurgery.The use of robotics in surgery is broad-based and will undoubtedly expand over the next decade as new technical innovations and techniques increase the applicability of its use. The journal intends to capture this trend as it develops.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书