{"title":"A wearable vibroarthrography system with PID-controlled negative-pressure suction and synchronized posture estimation.","authors":"Jiun-Hung Lin, Shih-Tsang Tang","doi":"10.1177/09287329261496167","DOIUrl":null,"url":null,"abstract":"<p><p>BackgroundVibroarthrography (VAG) is a non-invasive technique for evaluating joint health through acoustic signals generated during movement. However, reliable signal acquisition during dynamic activities remains challenging due to sensor displacement, motion artifacts, and inconsistent skin contact.ObjectiveThis study proposes an advanced wearable VAG system integrating PID-controlled negative-pressure suction and real-time posture estimation to improve signal stability and enhance the assessment of knee joint mechanics during movement.MethodsThe proposed system combines a wearable acoustic sensing module with a vacuum-assisted suction cup and a PID controller that consistently maintains sensor adhesion. Real-time posture estimation is achieved using MediaPipe Pose, which computes knee flexion angles. VAG signals and kinematic data are synchronously acquired during OKC and CKC exercises for integrated analysis.ResultsIn this single-subject pilot test, the system achieved stable sensor attachment and repeatable vibroacoustic recordings throughout dynamic movements. Distinguishable frequency-domain characteristics were observed at relevant knee flexion angles, including approximately 30°, 63°, and 129°.ConclusionsThis pilot feasibility study demonstrates that the proposed wearable VAG platform can achieve stable acquisition of synchronized vibroacoustic and kinematic signals during dynamic knee movement in a single subject. These preliminary findings suggest potential future applications in osteoarthritis screening, rehabilitation assessment, and ambulatory monitoring, pending validation in larger, statistically powered cohorts.</p>","PeriodicalId":48978,"journal":{"name":"Technology and Health Care","volume":" ","pages":"9287329261496167"},"PeriodicalIF":1.3000,"publicationDate":"2026-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technology and Health Care","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09287329261496167","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
BackgroundVibroarthrography (VAG) is a non-invasive technique for evaluating joint health through acoustic signals generated during movement. However, reliable signal acquisition during dynamic activities remains challenging due to sensor displacement, motion artifacts, and inconsistent skin contact.ObjectiveThis study proposes an advanced wearable VAG system integrating PID-controlled negative-pressure suction and real-time posture estimation to improve signal stability and enhance the assessment of knee joint mechanics during movement.MethodsThe proposed system combines a wearable acoustic sensing module with a vacuum-assisted suction cup and a PID controller that consistently maintains sensor adhesion. Real-time posture estimation is achieved using MediaPipe Pose, which computes knee flexion angles. VAG signals and kinematic data are synchronously acquired during OKC and CKC exercises for integrated analysis.ResultsIn this single-subject pilot test, the system achieved stable sensor attachment and repeatable vibroacoustic recordings throughout dynamic movements. Distinguishable frequency-domain characteristics were observed at relevant knee flexion angles, including approximately 30°, 63°, and 129°.ConclusionsThis pilot feasibility study demonstrates that the proposed wearable VAG platform can achieve stable acquisition of synchronized vibroacoustic and kinematic signals during dynamic knee movement in a single subject. These preliminary findings suggest potential future applications in osteoarthritis screening, rehabilitation assessment, and ambulatory monitoring, pending validation in larger, statistically powered cohorts.
期刊介绍:
Technology and Health Care is intended to serve as a forum for the presentation of original articles and technical notes, observing rigorous scientific standards. Furthermore, upon invitation, reviews, tutorials, discussion papers and minisymposia are featured. The main focus of THC is related to the overlapping areas of engineering and medicine. The following types of contributions are considered:
1.Original articles: New concepts, procedures and devices associated with the use of technology in medical research and clinical practice are presented to a readership with a widespread background in engineering and/or medicine. In particular, the clinical benefit deriving from the application of engineering methods and devices in clinical medicine should be demonstrated. Typically, full length original contributions have a length of 4000 words, thereby taking duly into account figures and tables.
2.Technical Notes and Short Communications: Technical Notes relate to novel technical developments with relevance for clinical medicine. In Short Communications, clinical applications are shortly described. 3.Both Technical Notes and Short Communications typically have a length of 1500 words.
Reviews and Tutorials (upon invitation only): Tutorial and educational articles for persons with a primarily medical background on principles of engineering with particular significance for biomedical applications and vice versa are presented. The Editorial Board is responsible for the selection of topics.
4.Minisymposia (upon invitation only): Under the leadership of a Special Editor, controversial or important issues relating to health care are highlighted and discussed by various authors.
5.Letters to the Editors: Discussions or short statements (not indexed).