Linearizing phase retrieval: the theory of near-focus interference.

IF 1.5 3区 物理与天体物理 Q3 OPTICS
Martin Berz, Christoph Dillitzer, Stefanos Kekkas, Johannes Pittrich, Hristo Iglev, Oliver Hayden
{"title":"Linearizing phase retrieval: the theory of near-focus interference.","authors":"Martin Berz, Christoph Dillitzer, Stefanos Kekkas, Johannes Pittrich, Hristo Iglev, Oliver Hayden","doi":"10.1364/JOSAA.603931","DOIUrl":null,"url":null,"abstract":"<p><p>Phase retrieval from square-law detectors in common path is traditionally a nonlinear, nonconvex inverse problem requiring complex iterative algorithms. Near-focus interference (NFI) uniquely enables direct linearization of self-referential phase retrieval. NFI exploits the interference between the longitudinal evolution of a coherent wavefield over a short free-space propagation-just a few Rayleigh distances-and the unpropagated self. NFI equations assume nothing about the complex fields except that they are bandlimited and fully represented on a sampling grid. Rigorous theory shows the reconstructed complex field is unique and depends continuously on the measured interference term and a single intensity, ensuring stability. Numerically, NFI is applied to bright-field and pure dark-field microscopy via projection onto a discrete hexagonal basis and a coordinate-free Krylov subspace least-squares analysis (LSA). In bright field, the phase locks to the known background field. In dark field, a data-driven bootstrap provides an initial guess for the LSA, resolving the global phase factor ambiguity common to self-referential measurements. Numerical simulations with 8-bit noise show recovery of 900 independent scatterers in 5 iterations. Experimental bright-field results are shown for samples much larger than the defocused diffraction spot. Beyond these guarantees of uniqueness and continuity, the principal practical advantage of NFI over state-of-the-art quantitative phase imaging is self-calibration: the propagation operator and the complex field are recovered directly from the noisy measurement, without external calibration standards, and the same reconstruction is obtained even after realignment of the instrument. These properties provide a foundation for standardized quantitative phase imaging across instruments and laboratories, facilitating adoption in medical diagnostics.</p>","PeriodicalId":17382,"journal":{"name":"Journal of The Optical Society of America A-optics Image Science and Vision","volume":"43 9","pages":"1420-1434"},"PeriodicalIF":1.5000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Optical Society of America A-optics Image Science and Vision","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1364/JOSAA.603931","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Phase retrieval from square-law detectors in common path is traditionally a nonlinear, nonconvex inverse problem requiring complex iterative algorithms. Near-focus interference (NFI) uniquely enables direct linearization of self-referential phase retrieval. NFI exploits the interference between the longitudinal evolution of a coherent wavefield over a short free-space propagation-just a few Rayleigh distances-and the unpropagated self. NFI equations assume nothing about the complex fields except that they are bandlimited and fully represented on a sampling grid. Rigorous theory shows the reconstructed complex field is unique and depends continuously on the measured interference term and a single intensity, ensuring stability. Numerically, NFI is applied to bright-field and pure dark-field microscopy via projection onto a discrete hexagonal basis and a coordinate-free Krylov subspace least-squares analysis (LSA). In bright field, the phase locks to the known background field. In dark field, a data-driven bootstrap provides an initial guess for the LSA, resolving the global phase factor ambiguity common to self-referential measurements. Numerical simulations with 8-bit noise show recovery of 900 independent scatterers in 5 iterations. Experimental bright-field results are shown for samples much larger than the defocused diffraction spot. Beyond these guarantees of uniqueness and continuity, the principal practical advantage of NFI over state-of-the-art quantitative phase imaging is self-calibration: the propagation operator and the complex field are recovered directly from the noisy measurement, without external calibration standards, and the same reconstruction is obtained even after realignment of the instrument. These properties provide a foundation for standardized quantitative phase imaging across instruments and laboratories, facilitating adoption in medical diagnostics.

线性化阶段检索:near-focus干涉理论。
从共路径的平方律检测器中提取相位,传统上是一个非线性、非凸的逆问题,需要复杂的迭代算法。近焦干涉(NFI)独特地实现了自参考相位恢复的直接线性化。NFI利用了短时间自由空间传播(只有几个瑞利距离)的相干波场纵向演化与未传播的自身之间的干扰。NFI方程对复杂的场没有任何假设,除非它们是带宽有限的,并且在采样网格上完全表示。严密的理论表明,重建的复场是唯一的,连续依赖于被测干涉项和单一强度,保证了稳定性。数值上,NFI通过在离散六边形基上的投影和无坐标的Krylov子空间最小二乘分析(LSA)应用于明场和纯暗场显微镜。在亮场中,相位锁定在已知的背景场中。在暗域中,数据驱动的bootstrap为LSA提供了初始猜测,解决了自参考测量中常见的全局相位因子模糊问题。在8位噪声条件下的数值模拟表明,在5次迭代中可以恢复900个独立散射体。对于比离焦衍射斑大得多的样品,给出了实验亮场结果。除了这些独特性和连续性的保证之外,NFI相对于最先进的定量相位成像的主要实际优势是自校准:传播算子和复杂场直接从噪声测量中恢复,不需要外部校准标准,即使在重新校准仪器后也能获得相同的重建。这些特性为跨仪器和实验室的标准化定量相位成像提供了基础,促进了医学诊断的采用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.40
自引率
10.50%
发文量
417
审稿时长
3 months
期刊介绍: The Journal of the Optical Society of America A (JOSA A) is devoted to developments in any field of classical optics, image science, and vision. JOSA A includes original peer-reviewed papers on such topics as: * Atmospheric optics * Clinical vision * Coherence and Statistical Optics * Color * Diffraction and gratings * Image processing * Machine vision * Physiological optics * Polarization * Scattering * Signal processing * Thin films * Visual optics Also: j opt soc am a.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书