Bio-inspired electrosurgical knife with lubricant-assisted porous-groove surface and micro-serrated edge for reducing tissue adhesion and thermal injury.

IF 1.8 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Chen Li, Lifangke Liu, Jing Zhao, Zhen Shi, Lin Wang, Liping Zhou, Xiaodong Wang, Weibo Dou
{"title":"Bio-inspired electrosurgical knife with lubricant-assisted porous-groove surface and micro-serrated edge for reducing tissue adhesion and thermal injury.","authors":"Chen Li, Lifangke Liu, Jing Zhao, Zhen Shi, Lin Wang, Liping Zhou, Xiaodong Wang, Weibo Dou","doi":"10.1177/09544119261492543","DOIUrl":null,"url":null,"abstract":"<p><p>Tissue adhesion and thermal injury remain major challenges in high-frequency electrosurgery because carbonized residues can accumulate on the electrode surface and reduce cutting stability. To address this issue, a coating-free bio-inspired electrosurgical knife was designed and fabricated from 316L stainless steel by selective laser melting. Inspired by loach-skin lubrication and anti-fouling characteristics, a porous-groove blade surface was designed for lubricant storage and transport. Inspired by crab-chela serrations, a micro-serrated cutting edge was introduced to reduce cutting resistance. Fluid-flow simulation showed that the porous-groove surface promoted lubricant retention and local recirculation, reducing near-wall resistance by up to 20.73%. Friction tests indicated that <i>D</i><sub>p</sub> = 350 μm and <i>L</i><sub>p</sub> = 800 μm produced the lowest lubricated friction coefficient of 0.362 among the tested porous-groove surfaces. Static cutting simulation and cutting-force tests confirmed that the micro-serrated edge reduced cutting resistance, with the lowest peak cutting force of approximately 0.605 N obtained at <i>H</i><sub>1</sub> = 300 μm. Powered electrosurgical tests showed that the sample with <i>D</i><sub>p</sub> = 350 μm, <i>L</i><sub>p</sub> = 800 μm, and <i>H</i><sub>1</sub> = 300 μm achieved the lowest apparent adhesion mass of 2.07 ± 0.67 mg, corresponding to a 61.5% reduction compared with the DT401 commercial smooth control electrode. The thermal damage areas on the upper and lateral tissue surfaces were reduced by 56.75% and 54.44%, respectively. These results demonstrate an effective engineering strategy for improving the anti-adhesion and thermal-safety performance of electrosurgical knives.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"9544119261492543"},"PeriodicalIF":1.8000,"publicationDate":"2026-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09544119261492543","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Tissue adhesion and thermal injury remain major challenges in high-frequency electrosurgery because carbonized residues can accumulate on the electrode surface and reduce cutting stability. To address this issue, a coating-free bio-inspired electrosurgical knife was designed and fabricated from 316L stainless steel by selective laser melting. Inspired by loach-skin lubrication and anti-fouling characteristics, a porous-groove blade surface was designed for lubricant storage and transport. Inspired by crab-chela serrations, a micro-serrated cutting edge was introduced to reduce cutting resistance. Fluid-flow simulation showed that the porous-groove surface promoted lubricant retention and local recirculation, reducing near-wall resistance by up to 20.73%. Friction tests indicated that Dp = 350 μm and Lp = 800 μm produced the lowest lubricated friction coefficient of 0.362 among the tested porous-groove surfaces. Static cutting simulation and cutting-force tests confirmed that the micro-serrated edge reduced cutting resistance, with the lowest peak cutting force of approximately 0.605 N obtained at H1 = 300 μm. Powered electrosurgical tests showed that the sample with Dp = 350 μm, Lp = 800 μm, and H1 = 300 μm achieved the lowest apparent adhesion mass of 2.07 ± 0.67 mg, corresponding to a 61.5% reduction compared with the DT401 commercial smooth control electrode. The thermal damage areas on the upper and lateral tissue surfaces were reduced by 56.75% and 54.44%, respectively. These results demonstrate an effective engineering strategy for improving the anti-adhesion and thermal-safety performance of electrosurgical knives.

仿生电刀,润滑辅助多孔槽表面和微锯齿边缘,减少组织粘连和热损伤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
5.60%
发文量
122
审稿时长
6 months
期刊介绍: The Journal of Engineering in Medicine is an interdisciplinary journal encompassing all aspects of engineering in medicine. The Journal is a vital tool for maintaining an understanding of the newest techniques and research in medical engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书