Circular comparison of finish lines obtained from digital scans and conventional impressions: A clinical study.

IF 5.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Heng Chen, Shaza Bishti, Sven Reich
{"title":"Circular comparison of finish lines obtained from digital scans and conventional impressions: A clinical study.","authors":"Heng Chen, Shaza Bishti, Sven Reich","doi":"10.1016/j.prosdent.2026.07.037","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>Clinical studies that have investigated whether intraoral scanners (IOSs) are equivalent or even superior to conventional impressions in capturing subgingival finish lines are sparse.</p><p><strong>Purpose: </strong>The purpose of this clinical study was to compare circumferentially the course of subgingival chamfer preparations captured by both digital scans (DIGI) and conventional impressions (CONI) using CONI as reference.</p><p><strong>Material and methods: </strong>Sixteen patients with a total of 50 teeth requiring crown preparations were included. For each die, a conventional polyether double-mix impression was made for the CONI workflow, and an intraoral scan was obtained for the DIGI setup. The CONI definitive casts were digitized, and the finish lines of the dies were defined for both workflows. The corresponding CONI and DIGI dies were registered. The deviations of the finish lines were analyzed circumferentially using an inspection software program with CONI as the reference. Positive (apical) and negative (coronal) deviations were calculated. Descriptive statistics were computed, normality was assessed using the Shapiro-Wilk test, and differences among tooth regions were analyzed using a linear mixed-effects model (α=.05).</p><p><strong>Results: </strong>On average, 9% of the DIGI finish lines were apical relative to the CONI margins, with a mean ±standard deviation of 68 ±54 µm. In contrast, 91% of the DIGI finish lines were located coronally, with a mean ±standard deviation of 245 ±108 µm. There were no statistically differences among tooth regions (P>.05).</p><p><strong>Conclusions: </strong>The results of this study suggest that digital scans may not capture subgingival preparation margins with the same accuracy as conventional methods.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":""},"PeriodicalIF":5.6000,"publicationDate":"2026-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2026.07.037","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem: Clinical studies that have investigated whether intraoral scanners (IOSs) are equivalent or even superior to conventional impressions in capturing subgingival finish lines are sparse.

Purpose: The purpose of this clinical study was to compare circumferentially the course of subgingival chamfer preparations captured by both digital scans (DIGI) and conventional impressions (CONI) using CONI as reference.

Material and methods: Sixteen patients with a total of 50 teeth requiring crown preparations were included. For each die, a conventional polyether double-mix impression was made for the CONI workflow, and an intraoral scan was obtained for the DIGI setup. The CONI definitive casts were digitized, and the finish lines of the dies were defined for both workflows. The corresponding CONI and DIGI dies were registered. The deviations of the finish lines were analyzed circumferentially using an inspection software program with CONI as the reference. Positive (apical) and negative (coronal) deviations were calculated. Descriptive statistics were computed, normality was assessed using the Shapiro-Wilk test, and differences among tooth regions were analyzed using a linear mixed-effects model (α=.05).

Results: On average, 9% of the DIGI finish lines were apical relative to the CONI margins, with a mean ±standard deviation of 68 ±54 µm. In contrast, 91% of the DIGI finish lines were located coronally, with a mean ±standard deviation of 245 ±108 µm. There were no statistically differences among tooth regions (P>.05).

Conclusions: The results of this study suggest that digital scans may not capture subgingival preparation margins with the same accuracy as conventional methods.

从数字扫描和常规印象获得的终点线的循环比较:一项临床研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书