{"title":"A user-friendly ear-EEG-based brain-computer interface using text sequence stimulation","authors":"Xiaoyang Li, Zhuoran Xu, Bowen Li, Yijun Wang, Xiaorong Gao","doi":"10.1016/j.bbe.2026.10.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Ear-EEG-based brain-computer interfaces (BCIs) provide improved wearability and comfort compared to traditional scalp-EEG systems. However, their performance is constrained by low signal-to-noise ratios (SNRs) and high rates of BCI illiteracy under conventional luminance-modulated steady-state visual evoked potential (SSVEP) paradigms.</div></div><div><h3>Methods</h3><div>This study introduces a text sequence stimulation paradigm to address these limitations. Using offline frequency-sweeping experiments across 4–8 Hz, we identified optimal stimulus parameters (4.6–6.8 Hz with 0.25π phase shifts) and integrated them into a 12-target BCI system. We further conducted online experiments to compare the response characteristics and real-time spelling performance between the proposed text sequence stimulation and conventional luminance stimulation.</div></div><div><h3>Results</h3><div>Comparative experiments with 14 participants demonstrated that text sequence stimulation achieved an average information transfer rate (ITR) of 44.59 ± 10.50 bits/min, representing a 76.18% higher ITR than the tested luminance stimulation implementation. Notably, 13 of the 14 participants achieved at least 70% accuracy with text sequence stimulation, while the remaining participant achieved 69.17% (mean: 86.37 ± 9.61%). In comparison, seven participants achieved less than 70% accuracy under luminance stimulation.</div></div><div><h3>Conclusions</h3><div>Text sequence stimulation received more favorable short term subjective ratings than luminance stimulation. The online results indicate its potential as a high performance and user friendly paradigm for ear-EEG BCIs. However, because the two implementations differed in stimulus content and stimulation parameters, further studies with matched control conditions and larger samples are needed.</div></div>","PeriodicalId":55381,"journal":{"name":"Biocybernetics and Biomedical Engineering","volume":"46 4","pages":"Pages 696-706"},"PeriodicalIF":4.9000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biocybernetics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0208521626000719","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/10/7 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Ear-EEG-based brain-computer interfaces (BCIs) provide improved wearability and comfort compared to traditional scalp-EEG systems. However, their performance is constrained by low signal-to-noise ratios (SNRs) and high rates of BCI illiteracy under conventional luminance-modulated steady-state visual evoked potential (SSVEP) paradigms.
Methods
This study introduces a text sequence stimulation paradigm to address these limitations. Using offline frequency-sweeping experiments across 4–8 Hz, we identified optimal stimulus parameters (4.6–6.8 Hz with 0.25π phase shifts) and integrated them into a 12-target BCI system. We further conducted online experiments to compare the response characteristics and real-time spelling performance between the proposed text sequence stimulation and conventional luminance stimulation.
Results
Comparative experiments with 14 participants demonstrated that text sequence stimulation achieved an average information transfer rate (ITR) of 44.59 ± 10.50 bits/min, representing a 76.18% higher ITR than the tested luminance stimulation implementation. Notably, 13 of the 14 participants achieved at least 70% accuracy with text sequence stimulation, while the remaining participant achieved 69.17% (mean: 86.37 ± 9.61%). In comparison, seven participants achieved less than 70% accuracy under luminance stimulation.
Conclusions
Text sequence stimulation received more favorable short term subjective ratings than luminance stimulation. The online results indicate its potential as a high performance and user friendly paradigm for ear-EEG BCIs. However, because the two implementations differed in stimulus content and stimulation parameters, further studies with matched control conditions and larger samples are needed.
期刊介绍:
Biocybernetics and Biomedical Engineering is a quarterly journal, founded in 1981, devoted to publishing the results of original, innovative and creative research investigations in the field of Biocybernetics and biomedical engineering, which bridges mathematical, physical, chemical and engineering methods and technology to analyse physiological processes in living organisms as well as to develop methods, devices and systems used in biology and medicine, mainly in medical diagnosis, monitoring systems and therapy. The Journal''s mission is to advance scientific discovery into new or improved standards of care, and promotion a wide-ranging exchange between science and its application to humans.