Effect of connector dimensions and span length on fracture resistance of high-translucency 4Y-TZP: An in vitro and finite element study.

IF 5.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Anna Thereza Peroba Rezende Ramos, Austin Heath, Daler Elisa Tarrazzi, Mateus Garcia Rocha, Rafael Rocha Pacheco
{"title":"Effect of connector dimensions and span length on fracture resistance of high-translucency 4Y-TZP: An in vitro and finite element study.","authors":"Anna Thereza Peroba Rezende Ramos, Austin Heath, Daler Elisa Tarrazzi, Mateus Garcia Rocha, Rafael Rocha Pacheco","doi":"10.1016/j.prosdent.2026.09.010","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>High-translucency 4-mol% yttria-stabilized tetragonal zirconia polycrystal (4Y-TZP) has been increasingly used for implant-supported prostheses because of its superior esthetics, yet connector size recommendations have been derived from studies of stronger conventional 3-mol% Y-TZP. Whether these guidelines remain valid for materials with 30 to 40% lower flexural strength is unknown.</p><p><strong>Purpose: </strong>The purpose of this in vitro and finite element study was to evaluate the effect of connector cross-sectional dimensions and span length on the fracture resistance of high-translucency monolithic 4Y-TZP and to characterize stress distribution and concentration at the connector.</p><p><strong>Material and methods: </strong>Bar-shaped specimens incorporating 4 connector regions were milled from presintered high-translucency 4Y-TZP (KATANA Zirconia HTML PLUS A2). Four connector configurations were tested: 3×3 mm, 4×3 mm, 4×4 mm (elliptical cross-sections), and 5×4 mm (full cross-section control), with cross-sectional areas of 7.1, 9.4, 12.6, and 20.0 mm². The specimens were tested at 2 span lengths (22 and 42 mm) by 3-point bend testing (n=6 per group). Fracture load (N) was recorded, and flexural stress at the connector (MPa) was calculated from the local bending moment and the section modulus appropriate to each cross-sectional geometry. Three-dimensional finite element models determined maximum principal stress (σ₁) and stress concentration factors. Data were analyzed with 2-way analysis of variance (ANOVA), the Tukey honestly significant difference (HSD) test, and the Pearson correlation (α=.05).</p><p><strong>Results: </strong>Connector configuration (P<.001), span length (P<.001), and their interaction (P<.001) significantly affected fracture load. Mean ±standard deviation fracture load ranged from 208 ±14 N (3×3 mm, 42-mm span) to 1806 ±142 N (5×4 mm, 22-mm span) and correlated strongly with connector area (r≥.979, P<.001). Load gain per mm² of connector area was approximately twice as large for the 22-mm span (98.3 N per mm²) as for the 42-mm span (52.3 N per mm²). When load was converted to flexural stress at the connector, only connector configuration remained significant (P<.001); span length (P=.816) and the interaction (P=.162) were not significant. Connector stress converged into a narrow range (533 to 745 MPa) within published 4Y-TZP flexural strength values. Finite element analysis confirmed stress concentration at the connector base, with σ₁ spanning a factor of only 1.5 (613 to 939 MPa) despite an 8.7-fold range in fracture loads. Under equal applied load, stress concentration factors ranged from 1.67 to 3.92 at the 22-mm span and from 2.62 to 6.42 at the 42-mm span.</p><p><strong>Conclusions: </strong>Reducing connector area disproportionately decreased fracture load, with greater reduction at longer spans. Connector stress values fell within a narrower range than fracture loads, suggesting that load differences are driven predominantly by geometry.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":""},"PeriodicalIF":5.6000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2026.09.010","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem: High-translucency 4-mol% yttria-stabilized tetragonal zirconia polycrystal (4Y-TZP) has been increasingly used for implant-supported prostheses because of its superior esthetics, yet connector size recommendations have been derived from studies of stronger conventional 3-mol% Y-TZP. Whether these guidelines remain valid for materials with 30 to 40% lower flexural strength is unknown.

Purpose: The purpose of this in vitro and finite element study was to evaluate the effect of connector cross-sectional dimensions and span length on the fracture resistance of high-translucency monolithic 4Y-TZP and to characterize stress distribution and concentration at the connector.

Material and methods: Bar-shaped specimens incorporating 4 connector regions were milled from presintered high-translucency 4Y-TZP (KATANA Zirconia HTML PLUS A2). Four connector configurations were tested: 3×3 mm, 4×3 mm, 4×4 mm (elliptical cross-sections), and 5×4 mm (full cross-section control), with cross-sectional areas of 7.1, 9.4, 12.6, and 20.0 mm². The specimens were tested at 2 span lengths (22 and 42 mm) by 3-point bend testing (n=6 per group). Fracture load (N) was recorded, and flexural stress at the connector (MPa) was calculated from the local bending moment and the section modulus appropriate to each cross-sectional geometry. Three-dimensional finite element models determined maximum principal stress (σ₁) and stress concentration factors. Data were analyzed with 2-way analysis of variance (ANOVA), the Tukey honestly significant difference (HSD) test, and the Pearson correlation (α=.05).

Results: Connector configuration (P<.001), span length (P<.001), and their interaction (P<.001) significantly affected fracture load. Mean ±standard deviation fracture load ranged from 208 ±14 N (3×3 mm, 42-mm span) to 1806 ±142 N (5×4 mm, 22-mm span) and correlated strongly with connector area (r≥.979, P<.001). Load gain per mm² of connector area was approximately twice as large for the 22-mm span (98.3 N per mm²) as for the 42-mm span (52.3 N per mm²). When load was converted to flexural stress at the connector, only connector configuration remained significant (P<.001); span length (P=.816) and the interaction (P=.162) were not significant. Connector stress converged into a narrow range (533 to 745 MPa) within published 4Y-TZP flexural strength values. Finite element analysis confirmed stress concentration at the connector base, with σ₁ spanning a factor of only 1.5 (613 to 939 MPa) despite an 8.7-fold range in fracture loads. Under equal applied load, stress concentration factors ranged from 1.67 to 3.92 at the 22-mm span and from 2.62 to 6.42 at the 42-mm span.

Conclusions: Reducing connector area disproportionately decreased fracture load, with greater reduction at longer spans. Connector stress values fell within a narrower range than fracture loads, suggesting that load differences are driven predominantly by geometry.

连接器尺寸和跨长对高半透明4Y-TZP抗断裂性能的影响:体外和有限元研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书