Association Between Wrist-Worn Device-Estimated Sleep Efficiency and Hand Grip Strength in Older Outpatients With Cardiometabolic Diseases: Cross-Sectional Study.

IF 2.4 Q3 HEALTH CARE SCIENCES & SERVICES
Yoshiaki Tamura, Rui Gong, Yuji Murao, Fumino Kobayashi, Satomi Kobayashi, Remi Kodera, Kazuhito Oba, Maki Shirobe, Kenji Toyoshima, Kanae Kubo, Yuko Chiba, Hisashi Kawai, Joji Ishikawa, Hiroyuki Sasai, Yoshinori Fujiwara, Shunei Kyo, Kenji Toba, Masahiro Akishita, Shuichi Obuchi, Atsushi Araki
{"title":"Association Between Wrist-Worn Device-Estimated Sleep Efficiency and Hand Grip Strength in Older Outpatients With Cardiometabolic Diseases: Cross-Sectional Study.","authors":"Yoshiaki Tamura, Rui Gong, Yuji Murao, Fumino Kobayashi, Satomi Kobayashi, Remi Kodera, Kazuhito Oba, Maki Shirobe, Kenji Toyoshima, Kanae Kubo, Yuko Chiba, Hisashi Kawai, Joji Ishikawa, Hiroyuki Sasai, Yoshinori Fujiwara, Shunei Kyo, Kenji Toba, Masahiro Akishita, Shuichi Obuchi, Atsushi Araki","doi":"10.2196/95303","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Older outpatients with chronic diseases are susceptible to muscle weakness and functional disabilities. Recently, various wearable devices have been developed to generate health lifelogs in daily life; however, data from patients with chronic diseases remain scarce. Previous studies have shown that subjective sleep efficiency assessed by self-questionnaires is associated with grip strength, but whether objective sleep efficiency detected by wearable devices is associated with physical function and body composition remains unclear.</p><p><strong>Objective: </strong>The aim of this study is to clarify the association between sleep duration, sleep efficiency estimated by wearable watch, grip strength, frailty, and sarcopenia in outpatients with predominantly cardiometabolic diseases and the influence of diabetes as part of the Smart Watch Innovation for Geriatrics and Gerontology (SWING-Japan) project.</p><p><strong>Methods: </strong>In this cross-sectional study, the wrist-worn device Silmee 22 was used in an outpatient clinic of an acute care facility for 7-90 nights for the analyses, and individual average sleep duration and efficiency (wearable-estimated sleep efficiency: total sleep duration/time spent in bed) were calculated. Low grip strength was defined as <28 kg for men and <18 kg for women. Sarcopenia was defined based on the Asian criteria and frailty based on the Japanese version of Cardiovascular Health Study and Kihon Checklist criteria. Sleep indices were compared between individuals with and without these conditions. Next, logistic regression analysis was performed, with lower grip strength as the dependent variable and wearable-estimated sleep efficiency as the independent variable, adjusted for age, sex, BMI, glycohemoglobin, cognitive function (Mini-Mental State Examination), Geriatric Depression Scale-15 score, and daily step count measured using the ankle-worn device WalkX. Subgroup analyses were performed and stratified according to the status of diabetes mellitus.</p><p><strong>Results: </strong>Data from 165 patients (median age: 77 y; duration of device use: 65 d; diabetes prevalence: 55%) were used for analyses. Wearable-estimated sleep efficiency and sleep duration were significantly lower in patients with low grip strength than in those without (58.0% vs 62.7%, <i>P</i>=.006, 245 vs 276 min, <i>P</i>=.04). Wearable-estimated sleep efficiency was not associated with frailty, low muscle mass, or slow walking speed. After adjusting for the above variables, low wearable-estimated sleep efficiency, but not low sleep duration, was associated with a risk of lower grip strength (odds ratio 1.04, 95% CI 1.01-1.08; <i>P</i>=.02) by 1 percentage point decrease in wearable-estimated sleep efficiency. This association was observed in patients with diabetes (odds ratio 1.05, 95% CI 1.002-1.093; <i>P</i>=.04). However, no significant interaction was observed.</p><p><strong>Conclusions: </strong>In older patients with cardiometabolic diseases, objective low wearable-estimated sleep efficiency evaluated with wrist-worn wearable devices was associated with low muscle strength. No evidence was found to suggest that the strength of this association differed according to diabetes status. Longitudinal studies are needed to clarify the long-term association between low wearable-estimated sleep efficiency and muscle strength in this population.</p>","PeriodicalId":14841,"journal":{"name":"JMIR Formative Research","volume":"10 ","pages":"e95303"},"PeriodicalIF":2.4000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13652524/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JMIR Formative Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2196/95303","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Older outpatients with chronic diseases are susceptible to muscle weakness and functional disabilities. Recently, various wearable devices have been developed to generate health lifelogs in daily life; however, data from patients with chronic diseases remain scarce. Previous studies have shown that subjective sleep efficiency assessed by self-questionnaires is associated with grip strength, but whether objective sleep efficiency detected by wearable devices is associated with physical function and body composition remains unclear.

Objective: The aim of this study is to clarify the association between sleep duration, sleep efficiency estimated by wearable watch, grip strength, frailty, and sarcopenia in outpatients with predominantly cardiometabolic diseases and the influence of diabetes as part of the Smart Watch Innovation for Geriatrics and Gerontology (SWING-Japan) project.

Methods: In this cross-sectional study, the wrist-worn device Silmee 22 was used in an outpatient clinic of an acute care facility for 7-90 nights for the analyses, and individual average sleep duration and efficiency (wearable-estimated sleep efficiency: total sleep duration/time spent in bed) were calculated. Low grip strength was defined as <28 kg for men and <18 kg for women. Sarcopenia was defined based on the Asian criteria and frailty based on the Japanese version of Cardiovascular Health Study and Kihon Checklist criteria. Sleep indices were compared between individuals with and without these conditions. Next, logistic regression analysis was performed, with lower grip strength as the dependent variable and wearable-estimated sleep efficiency as the independent variable, adjusted for age, sex, BMI, glycohemoglobin, cognitive function (Mini-Mental State Examination), Geriatric Depression Scale-15 score, and daily step count measured using the ankle-worn device WalkX. Subgroup analyses were performed and stratified according to the status of diabetes mellitus.

Results: Data from 165 patients (median age: 77 y; duration of device use: 65 d; diabetes prevalence: 55%) were used for analyses. Wearable-estimated sleep efficiency and sleep duration were significantly lower in patients with low grip strength than in those without (58.0% vs 62.7%, P=.006, 245 vs 276 min, P=.04). Wearable-estimated sleep efficiency was not associated with frailty, low muscle mass, or slow walking speed. After adjusting for the above variables, low wearable-estimated sleep efficiency, but not low sleep duration, was associated with a risk of lower grip strength (odds ratio 1.04, 95% CI 1.01-1.08; P=.02) by 1 percentage point decrease in wearable-estimated sleep efficiency. This association was observed in patients with diabetes (odds ratio 1.05, 95% CI 1.002-1.093; P=.04). However, no significant interaction was observed.

Conclusions: In older patients with cardiometabolic diseases, objective low wearable-estimated sleep efficiency evaluated with wrist-worn wearable devices was associated with low muscle strength. No evidence was found to suggest that the strength of this association differed according to diabetes status. Longitudinal studies are needed to clarify the long-term association between low wearable-estimated sleep efficiency and muscle strength in this population.

老年心脏代谢疾病门诊患者腕带设备估计睡眠效率与握力之间的关系:横断面研究
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JMIR Formative Research
JMIR Formative Research Medicine-Medicine (miscellaneous)
CiteScore
2.70
自引率
9.10%
发文量
579
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书