Ensemble-based label adjudication (EBLA): A method for validating continuous physiological measures against observer-dependent reference standards.

IF 2.1 Q3 PHYSIOLOGY
Guillermo Gutierrez, Fernando Papa
{"title":"Ensemble-based label adjudication (EBLA): A method for validating continuous physiological measures against observer-dependent reference standards.","authors":"Guillermo Gutierrez, Fernando Papa","doi":"10.14814/phy2.71127","DOIUrl":null,"url":null,"abstract":"<p><p>Comparing a novel physiological measure against an observer-dependent reference standard creates uncertainty when results disagree because errors may arise from either method. We propose ensemble-based label adjudication (EBLA), a computational framework that uses agreement between two imperfect instruments to create a high-confidence training set for adjudicating discordant observations. EBLA was validated using the Wisconsin Breast Cancer Dataset (n = 569) with simulated label noise (10%-30%). Five classifiers were trained on concordant cases using stratified 5-fold cross-validation. In the primary 15%/15% noise scenario, majority-vote EBLA improved accuracy from 0.85 to 0.97, sensitivity from 0.87 to 0.98, and specificity from 0.84 to 0.97. Supermajority and unanimity thresholds did not improve accuracy and excluded 1.4% and 2.5% of cases. EBLA consistently outperformed Cleanlab across all noise conditions. Application to 281 paired Mechanical Ventilation Respiratory Distress Observation Scale (MV-RDOS) assessments and inspiratory effort measurements (PmusPTP) from 45 mechanically ventilated patients increased accuracy from 0.81 to 0.86, primarily by improving specificity from 0.88 to 0.94. EBLA provides a transparent, interpretable framework for sensitivity analysis when validating physiological measurements against imperfect observer-dependent reference standards.</p>","PeriodicalId":20083,"journal":{"name":"Physiological Reports","volume":"14 19","pages":"e71127"},"PeriodicalIF":2.1000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13653038/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14814/phy2.71127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Comparing a novel physiological measure against an observer-dependent reference standard creates uncertainty when results disagree because errors may arise from either method. We propose ensemble-based label adjudication (EBLA), a computational framework that uses agreement between two imperfect instruments to create a high-confidence training set for adjudicating discordant observations. EBLA was validated using the Wisconsin Breast Cancer Dataset (n = 569) with simulated label noise (10%-30%). Five classifiers were trained on concordant cases using stratified 5-fold cross-validation. In the primary 15%/15% noise scenario, majority-vote EBLA improved accuracy from 0.85 to 0.97, sensitivity from 0.87 to 0.98, and specificity from 0.84 to 0.97. Supermajority and unanimity thresholds did not improve accuracy and excluded 1.4% and 2.5% of cases. EBLA consistently outperformed Cleanlab across all noise conditions. Application to 281 paired Mechanical Ventilation Respiratory Distress Observation Scale (MV-RDOS) assessments and inspiratory effort measurements (PmusPTP) from 45 mechanically ventilated patients increased accuracy from 0.81 to 0.86, primarily by improving specificity from 0.88 to 0.94. EBLA provides a transparent, interpretable framework for sensitivity analysis when validating physiological measurements against imperfect observer-dependent reference standards.

基于集合的标签判定(EBLA):一种针对观察者依赖参考标准验证连续生理测量的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Physiological Reports
Physiological Reports PHYSIOLOGY-
CiteScore
4.20
自引率
4.00%
发文量
374
审稿时长
9 weeks
期刊介绍: Physiological Reports is an online only, open access journal that will publish peer reviewed research across all areas of basic, translational, and clinical physiology and allied disciplines. Physiological Reports is a collaboration between The Physiological Society and the American Physiological Society, and is therefore in a unique position to serve the international physiology community through quick time to publication while upholding a quality standard of sound research that constitutes a useful contribution to the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书