Indoor Air Quality and Exposure Characterization in Operational Waterpipe Cafés: Field Measurements of Particulate and Volatile Pollutants in Al-Madinah Al-Munawwarah
IF 2.7 2区 环境科学与生态学Q1 CONSTRUCTION & BUILDING TECHNOLOGY
Seham N. Aljabri, Samah Ali, Amr Mohamed, Osama Albarbarawi, Sultan K. Alharbi, Moayad M. Khashoqji, Eman A. Assirey
{"title":"Indoor Air Quality and Exposure Characterization in Operational Waterpipe Cafés: Field Measurements of Particulate and Volatile Pollutants in Al-Madinah Al-Munawwarah","authors":"Seham N. Aljabri, Samah Ali, Amr Mohamed, Osama Albarbarawi, Sultan K. Alharbi, Moayad M. Khashoqji, Eman A. Assirey","doi":"10.1155/ina/8494753","DOIUrl":null,"url":null,"abstract":"<p>Waterpipe cafés represent combustion-dominated indoor environments where tobacco heating and charcoal burning generate complex mixtures of airborne pollutants. Despite the widespread presence of such venues in Saudi Arabia and globally, quantitative field measurements describing real-world exposure conditions remain limited, particularly in the Gulf region. This study characterizes indoor air quality in five operational waterpipe cafés in Al-Madinah Al-Munawwarah through direct measurements of particulate matter (PM₂.₅ and PM₁₀), total volatile organic compounds (TVOCs), and formaldehyde (HCHO) during peak occupancy periods on weekdays and weekends. Substantial spatial and temporal variability in pollutant concentrations was observed across venues, largely reflecting differences in smoking intensity and ventilation effectiveness. Mean weekday PM₂.₅ and PM₁₀ concentrations reached 285.5 ± 149 <i>μ</i>g/m<sup>3</sup> and 301.6 ± 156 <i>μ</i>g/m<sup>3</sup>, respectively, while weekend TVOC concentrations averaged 0.50 mg/m<sup>3</sup>. In multiple instances, measured particulate and volatile pollutant levels exceeded international health-based guideline values, indicating elevated exposure potential under high-use conditions. Formaldehyde concentrations remained below short-term reference thresholds. The findings identify waterpipe cafés as significant indoor sources of fine particulate matter and volatile pollutants. This study provides region-specific evidence supporting the need for stricter indoor air quality regulations in waterpipe café environments. The results contribute to advancing national priorities in public health protection, environmental sustainability, and urban environmental management within Saudi Arabia.</p>","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":"2026 1","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2026-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/ina/8494753","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indoor air","FirstCategoryId":"93","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/ina/8494753","RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Waterpipe cafés represent combustion-dominated indoor environments where tobacco heating and charcoal burning generate complex mixtures of airborne pollutants. Despite the widespread presence of such venues in Saudi Arabia and globally, quantitative field measurements describing real-world exposure conditions remain limited, particularly in the Gulf region. This study characterizes indoor air quality in five operational waterpipe cafés in Al-Madinah Al-Munawwarah through direct measurements of particulate matter (PM₂.₅ and PM₁₀), total volatile organic compounds (TVOCs), and formaldehyde (HCHO) during peak occupancy periods on weekdays and weekends. Substantial spatial and temporal variability in pollutant concentrations was observed across venues, largely reflecting differences in smoking intensity and ventilation effectiveness. Mean weekday PM₂.₅ and PM₁₀ concentrations reached 285.5 ± 149 μg/m3 and 301.6 ± 156 μg/m3, respectively, while weekend TVOC concentrations averaged 0.50 mg/m3. In multiple instances, measured particulate and volatile pollutant levels exceeded international health-based guideline values, indicating elevated exposure potential under high-use conditions. Formaldehyde concentrations remained below short-term reference thresholds. The findings identify waterpipe cafés as significant indoor sources of fine particulate matter and volatile pollutants. This study provides region-specific evidence supporting the need for stricter indoor air quality regulations in waterpipe café environments. The results contribute to advancing national priorities in public health protection, environmental sustainability, and urban environmental management within Saudi Arabia.
期刊介绍:
The quality of the environment within buildings is a topic of major importance for public health.
Indoor Air provides a location for reporting original research results in the broad area defined by the indoor environment of non-industrial buildings. An international journal with multidisciplinary content, Indoor Air publishes papers reflecting the broad categories of interest in this field: health effects; thermal comfort; monitoring and modelling; source characterization; ventilation and other environmental control techniques.
The research results present the basic information to allow designers, building owners, and operators to provide a healthy and comfortable environment for building occupants, as well as giving medical practitioners information on how to deal with illnesses related to the indoor environment.