Comparison of biomechanical anchorage between apatite- and calcium titanate-modified implant surfaces.

IF 3.1 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Hee-Seung Han, Sungtae Kim, Narasaem Lee, Yongjoon Kim, Kyung-Il Kim, Young-Dan Cho
{"title":"Comparison of biomechanical anchorage between apatite- and calcium titanate-modified implant surfaces.","authors":"Hee-Seung Han, Sungtae Kim, Narasaem Lee, Yongjoon Kim, Kyung-Il Kim, Young-Dan Cho","doi":"10.5051/jpis.2601500075","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Implant surface chemistry and microstructure can substantially influence early osseointegration even when overall roughness is comparable. This study compared the surface characteristics, <i>in vitro</i> ion release, and <i>in vivo</i> osseointegration of a calcium titanate (CaTiO₃) nanofilm formed on a sandblasting combined with acid etching (SLA) surface (C surface) and an SLA surface bearing an additional ultrathin apatite nanolayer (A surface).</p><p><strong>Methods: </strong>Implant surface morphology and roughness were evaluated using field-emission scanning electron microscopy, laser confocal microscopy, and contact profilometry. Calcium ion release was quantified using the Arsenazo III colorimetric assay. Eight male mongrel dogs underwent extraction of the mandibular premolars and first molars. After a 3-month healing period, C- or A-surface implants were placed using standardized drilling protocols, and insertion torque was recorded. At 3 and 6 weeks, removal torque (RT) was measured, and histomorphometric analysis was performed to calculate the proportion of the implant surface in direct contact with newly formed bone.</p><p><strong>Results: </strong>Both surfaces exhibited moderately rough micro- and nanostructured topographies with similar roughness parameters. However, calcium ion release was significantly greater from the A surface. RT was also significantly higher for the A surface than for the C surface at both 3 and 6 weeks.</p><p><strong>Conclusions: </strong>Despite similar macrodesign and overall roughness, an ultrathin apatite nanolayer can accelerate early interfacial strengthening without altering midterm osseointegration.</p>","PeriodicalId":48795,"journal":{"name":"Journal of Periodontal and Implant Science","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2026-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Periodontal and Implant Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5051/jpis.2601500075","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Implant surface chemistry and microstructure can substantially influence early osseointegration even when overall roughness is comparable. This study compared the surface characteristics, in vitro ion release, and in vivo osseointegration of a calcium titanate (CaTiO₃) nanofilm formed on a sandblasting combined with acid etching (SLA) surface (C surface) and an SLA surface bearing an additional ultrathin apatite nanolayer (A surface).

Methods: Implant surface morphology and roughness were evaluated using field-emission scanning electron microscopy, laser confocal microscopy, and contact profilometry. Calcium ion release was quantified using the Arsenazo III colorimetric assay. Eight male mongrel dogs underwent extraction of the mandibular premolars and first molars. After a 3-month healing period, C- or A-surface implants were placed using standardized drilling protocols, and insertion torque was recorded. At 3 and 6 weeks, removal torque (RT) was measured, and histomorphometric analysis was performed to calculate the proportion of the implant surface in direct contact with newly formed bone.

Results: Both surfaces exhibited moderately rough micro- and nanostructured topographies with similar roughness parameters. However, calcium ion release was significantly greater from the A surface. RT was also significantly higher for the A surface than for the C surface at both 3 and 6 weeks.

Conclusions: Despite similar macrodesign and overall roughness, an ultrathin apatite nanolayer can accelerate early interfacial strengthening without altering midterm osseointegration.

磷灰石与钛酸钙改性种植体表面生物力学锚定的比较。
目的:种植体表面化学和微观结构可以显著影响早期骨整合,即使整体粗糙度相当。本研究比较了喷砂结合酸蚀(SLA)表面(C面)和附加超薄磷灰石纳米层(a面)的SLA表面上形成的钛酸钙(CaTiO₃)纳米膜的表面特性、体外离子释放和体内骨整合。方法:采用场发射扫描电镜、激光共聚焦显微镜和接触轮廓术对种植体表面形貌和粗糙度进行评价。用偶氮胂III比色法测定钙离子释放量。对8只雄性杂种犬进行了下颌前磨牙和第一磨牙的拔除。在3个月的愈合期后,采用标准化的钻孔方案放置C面或a面植入物,并记录植入扭矩。在第3周和第6周,测量移除扭矩(RT),并进行组织形态学分析,计算种植体表面与新形成骨直接接触的比例。结果:两个表面都表现出中等粗糙的微观和纳米结构地形,粗糙度参数相似。然而,钙离子在A表面的释放明显更大。在第3周和第6周,A表面的RT也显著高于C表面。结论:尽管宏观设计和整体粗糙度相似,超薄磷灰石纳米层可以在不改变中期骨整合的情况下加速早期界面强化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Periodontal and Implant Science
Journal of Periodontal and Implant Science DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
5.30%
发文量
38
期刊介绍: Journal of Periodontal & Implant Science (JPIS) is a peer-reviewed and open-access journal providing up-to-date information relevant to professionalism of periodontology and dental implantology. JPIS is dedicated to global and extensive publication which includes evidence-based original articles, and fundamental reviews in order to cover a variety of interests in the field of periodontal as well as implant science.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书