Outcomes following impedance threshold device use during out-of-hospital cardiac arrest.

IF 6 1区 医学 Q1 CRITICAL CARE MEDICINE
Aaron C Weidman, Remle P Crowe, Ali Treichel, James J Menegazzi
{"title":"Outcomes following impedance threshold device use during out-of-hospital cardiac arrest.","authors":"Aaron C Weidman, Remle P Crowe, Ali Treichel, James J Menegazzi","doi":"10.1016/j.resuscitation.2026.111340","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Existing work is equivocal regarding the benefit of impedance threshold device (ITD) use among patients experiencing out-of-hospital cardiac arrest (OHCA). We examined the association of ITD use with prehospital outcomes and longer-term dispositions in a nationally representative sample of OHCA patients.</p><p><strong>Methods: </strong>We included adult, non-traumatic, OHCA scene runs from the 2024 ESO Data Collaborative. We compared patients treated with (a) ITD only; (b) ITD and active compression-decompression device (ITD + ACD); and (c) neither device (no ITD). Prehospital outcomes included return of spontaneous circulation (ROSC) and survival to hospital arrival (SHA); disposition outcomes included survival to hospital discharge and favorable neurologic outcome (i.e., discharge to home). We used multivariate logistic regression to examine the association of treatment group with outcomes, adjusting for demographics and several potential confounders.</p><p><strong>Results: </strong>We included 97,439 patient records (85.3% no ITD; 13.1% ITD only; 1.6% ITD + ACD). Disposition outcomes were available for 13,026 patients (13.4%). ROSC was higher for patients treated with ITD only (26.7%) than those treated with no ITD (23.8%; aOR = 1.09 [1.04, 1.14]); a similar pattern emerged for SHA. Conversely, survival to discharge was lower for patients treated with ITD only (23.9%) than those treated with no ITD (32.0%; aOR = 0.68, [0.61, 0.76]); a similar pattern emerged for favorable neurologic outcome. The ITD + ACD group showed more extreme versions of the trends observed for ITD only.</p><p><strong>Conclusions: </strong>ITD use was associated with improved prehospital outcomes but worsened dispositional outcomes among patients experiencing OHCA, suggesting this device may prove beneficial early in resuscitation of OHCA patients.</p>","PeriodicalId":21052,"journal":{"name":"Resuscitation","volume":" ","pages":"111340"},"PeriodicalIF":6.0000,"publicationDate":"2026-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Resuscitation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.resuscitation.2026.111340","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Existing work is equivocal regarding the benefit of impedance threshold device (ITD) use among patients experiencing out-of-hospital cardiac arrest (OHCA). We examined the association of ITD use with prehospital outcomes and longer-term dispositions in a nationally representative sample of OHCA patients.

Methods: We included adult, non-traumatic, OHCA scene runs from the 2024 ESO Data Collaborative. We compared patients treated with (a) ITD only; (b) ITD and active compression-decompression device (ITD + ACD); and (c) neither device (no ITD). Prehospital outcomes included return of spontaneous circulation (ROSC) and survival to hospital arrival (SHA); disposition outcomes included survival to hospital discharge and favorable neurologic outcome (i.e., discharge to home). We used multivariate logistic regression to examine the association of treatment group with outcomes, adjusting for demographics and several potential confounders.

Results: We included 97,439 patient records (85.3% no ITD; 13.1% ITD only; 1.6% ITD + ACD). Disposition outcomes were available for 13,026 patients (13.4%). ROSC was higher for patients treated with ITD only (26.7%) than those treated with no ITD (23.8%; aOR = 1.09 [1.04, 1.14]); a similar pattern emerged for SHA. Conversely, survival to discharge was lower for patients treated with ITD only (23.9%) than those treated with no ITD (32.0%; aOR = 0.68, [0.61, 0.76]); a similar pattern emerged for favorable neurologic outcome. The ITD + ACD group showed more extreme versions of the trends observed for ITD only.

Conclusions: ITD use was associated with improved prehospital outcomes but worsened dispositional outcomes among patients experiencing OHCA, suggesting this device may prove beneficial early in resuscitation of OHCA patients.

院外心脏骤停期间使用阻抗阈值装置后的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Resuscitation
Resuscitation 医学-急救医学
CiteScore
12.00
自引率
18.50%
发文量
556
审稿时长
21 days
期刊介绍: Resuscitation is a monthly international and interdisciplinary medical journal. The papers published deal with the aetiology, pathophysiology and prevention of cardiac arrest, resuscitation training, clinical resuscitation, and experimental resuscitation research, although papers relating to animal studies will be published only if they are of exceptional interest and related directly to clinical cardiopulmonary resuscitation. Papers relating to trauma are published occasionally but the majority of these concern traumatic cardiac arrest.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书