The Effect of Different Gadolinium Delivery Rates on Objective and Subjective Image Quality in Cardiac Perfusion Magnetic Resonance Imaging.

IF 7.9 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Casper Mihl, Joey Cjg Pernot, Bjorn Winkens, Martijn W Smulders, Joachim E Wildberger, Robert J Holtackers, Bibi Martens
{"title":"The Effect of Different Gadolinium Delivery Rates on Objective and Subjective Image Quality in Cardiac Perfusion Magnetic Resonance Imaging.","authors":"Casper Mihl, Joey Cjg Pernot, Bjorn Winkens, Martijn W Smulders, Joachim E Wildberger, Robert J Holtackers, Bibi Martens","doi":"10.1097/RLI.0000000000001317","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Stress perfusion cardiac magnetic resonance imaging (MRI) enables accurate detection of myocardial ischemia. While contrast injection parameters, particularly iodine delivery rate, are known to influence image quality in CT, their impact in cardiac MRI remains insufficiently studied. This study aimed to evaluate the effect of different gadolinium-based contrast agent (GBCA) injection rates on objective and subjective image quality in perfusion cardiac MRI in patients with suspected ischemic heart disease.</p><p><strong>Methods: </strong>Ninety patients scheduled for a stress perfusion cardiac MRI were retrospectively included and allocated to 3 groups based on the GBCA injection rate used (eg, group 1: 6 mL/s, group 2: 4 mL/s, and group 3: 2 mL/s). Blood-pool signal intensity was extracted on a frame-by-frame basis to generate signal-intensity time curves. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated for all relevant regions, including SNRischemia, SNRblood, SNRmyocardium, CNRischemia-blood, CNRmyocardium-blood, and CNRischemia-myocardium. Subjective image quality was scored on a 5-point Likert scale, blindly assessed in consensus by 2 cardiovascular radiologists.</p><p><strong>Results: </strong>Blood-pool peak intensity was the highest in the group with flow rates of 6 mL/s. Peak signal intensity was for the 6, 4, and 2 mL/s group, respectively, 17525±3616, 15213±3416, and 15534±2990 a.u. (P=0.019) and post hoc comparison demonstrated a significant difference between the 6 mL/s and 4 mL/s group (P=0.027). No significant differences in signal intensity of the myocardium, blood pool and the infarcted region were found between groups (P=0.475, 0.399 and 0.519, respectively). Image noise was significantly higher in group 1 compared to group 3 (P value=0.036). SNR of myocardium, blood, and ischemia was not significantly different between groups (P=0.525, 0.595, and 0.453, respectively). CNR for ischemia-blood, myocardium-blood and ischemia-myocardium were the highest in group 3, but not significantly different (P=0.373, 0.896, and 0.346, respectively). Subjective image quality and reader confidence were not significantly different between groups (P values of 0.985 and 0.842). Although contrast quality demonstrated a statistically significant difference across groups (P=0.026), this finding was not considered clinically relevant.</p><p><strong>Conclusion: </strong>Higher GBCA injection rates resulted in higher blood-pool peak enhancement, yet did not translate into significant differences in objective image and subjective image quality. Lower injection rates appear sufficient to achieve adequate myocardial perfusion imaging, suggesting a plateau in image quality in which increasing flow rates do not show added benefit.</p>","PeriodicalId":14486,"journal":{"name":"Investigative Radiology","volume":" ","pages":""},"PeriodicalIF":7.9000,"publicationDate":"2026-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RLI.0000000000001317","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Stress perfusion cardiac magnetic resonance imaging (MRI) enables accurate detection of myocardial ischemia. While contrast injection parameters, particularly iodine delivery rate, are known to influence image quality in CT, their impact in cardiac MRI remains insufficiently studied. This study aimed to evaluate the effect of different gadolinium-based contrast agent (GBCA) injection rates on objective and subjective image quality in perfusion cardiac MRI in patients with suspected ischemic heart disease.

Methods: Ninety patients scheduled for a stress perfusion cardiac MRI were retrospectively included and allocated to 3 groups based on the GBCA injection rate used (eg, group 1: 6 mL/s, group 2: 4 mL/s, and group 3: 2 mL/s). Blood-pool signal intensity was extracted on a frame-by-frame basis to generate signal-intensity time curves. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated for all relevant regions, including SNRischemia, SNRblood, SNRmyocardium, CNRischemia-blood, CNRmyocardium-blood, and CNRischemia-myocardium. Subjective image quality was scored on a 5-point Likert scale, blindly assessed in consensus by 2 cardiovascular radiologists.

Results: Blood-pool peak intensity was the highest in the group with flow rates of 6 mL/s. Peak signal intensity was for the 6, 4, and 2 mL/s group, respectively, 17525±3616, 15213±3416, and 15534±2990 a.u. (P=0.019) and post hoc comparison demonstrated a significant difference between the 6 mL/s and 4 mL/s group (P=0.027). No significant differences in signal intensity of the myocardium, blood pool and the infarcted region were found between groups (P=0.475, 0.399 and 0.519, respectively). Image noise was significantly higher in group 1 compared to group 3 (P value=0.036). SNR of myocardium, blood, and ischemia was not significantly different between groups (P=0.525, 0.595, and 0.453, respectively). CNR for ischemia-blood, myocardium-blood and ischemia-myocardium were the highest in group 3, but not significantly different (P=0.373, 0.896, and 0.346, respectively). Subjective image quality and reader confidence were not significantly different between groups (P values of 0.985 and 0.842). Although contrast quality demonstrated a statistically significant difference across groups (P=0.026), this finding was not considered clinically relevant.

Conclusion: Higher GBCA injection rates resulted in higher blood-pool peak enhancement, yet did not translate into significant differences in objective image and subjective image quality. Lower injection rates appear sufficient to achieve adequate myocardial perfusion imaging, suggesting a plateau in image quality in which increasing flow rates do not show added benefit.

不同钆输送率对心脏灌注磁共振成像客观和主观图像质量的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Investigative Radiology
Investigative Radiology 医学-核医学
CiteScore
15.10
自引率
16.40%
发文量
188
审稿时长
4-8 weeks
期刊介绍: Investigative Radiology publishes original, peer-reviewed reports on clinical and laboratory investigations in diagnostic imaging, the diagnostic use of radioactive isotopes, computed tomography, positron emission tomography, magnetic resonance imaging, ultrasound, digital subtraction angiography, and related modalities. Emphasis is on early and timely publication. Primarily research-oriented, the journal also includes a wide variety of features of interest to clinical radiologists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书