Shoe-ground loading responses across three 3D-printed arch-support heights in normal- and high-arched marathon runners: an arch-type-stratified secondary analysis.
{"title":"Shoe-ground loading responses across three 3D-printed arch-support heights in normal- and high-arched marathon runners: an arch-type-stratified secondary analysis.","authors":"Xinran Dong, Tianzhe Liang, Yong Ma, Chengliang Wu","doi":"10.3389/fspor.2026.1942713","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>A prior parameter-optimization study identified 9-15-mm support heights at 22%-26% infill as a candidate range for 3D-printed arch-support inserts, but whether responses within this range differ between runners with normal and high arches remains unclear. This arch-type-stratified secondary analysis compared shoe-ground interface loading under Single and 9-, 12-, and 15-mm support conditions at 24% infill and explored the temporal localization of condition-related differences during stance.</p><p><strong>Methods: </strong>The primary balanced analysis included thirty male marathon runners (15 normal arch, 15 high arch), and a sensitivity analysis included all 55 eligible runners (40 normal arch, 15 high arch). A floor-mounted Footscan® system recorded shoe-ground pressure and regional force data. Primary outcomes were maximum regional peak pressure (MaxPP), maximum metatarsal-region peak pressure (MetaPP), midfoot force impulse fraction (MIF), heel force impulse fraction (HIF), and mediolateral impulse index (MLI). Prespecified comparisons used paired or Welch <i>t</i>-tests with Benjamini-Hochberg false-discovery-rate correction, complemented by Arch Type × Condition linear mixed-effects models and exploratory pointwise time-series analyses.</p><p><strong>Results: </strong>Under Single, none of the five primary outcomes differed between arch groups after FDR correction. In the primary balanced analysis, relative to Single, FDR-supported differences were concentrated in impulse-distribution measures: MIF increased by 17.9%-19.5% in normal-arch runners under 12-24 and 15-24 and by 18.0%-23.0% in high-arch runners across all three supports, whereas MLI decreased by 14.0%-24.0% and 12.0%-19.7%, respectively. In this analysis, no MaxPP or MetaPP comparison met the FDR threshold. In normal arches, MIF was 7.4% higher under 12-24 than 9-24 (<i>q</i> = 0.041) and 9.0% higher under 15-24 than 9-24 (<i>q</i> = 0.003); no direct support-condition comparison was FDR-significant in high arches. Neither the 15 between-arch change comparisons nor the five Arch Type × Condition interactions reached FDR significance in the balanced analysis, and the same 0/15 and 0/5 pattern was retained in the full-cohort sensitivity analysis. Exploratory temporal differences were localized mainly to early-to-middle stance for midfoot force share and middle-to-late stance for dynamic MLI.</p><p><strong>Conclusion: </strong>In the primary balanced analysis, condition-related differences were expressed more consistently in MIF and MLI than in peak-pressure measures. Across the balanced and full-cohort analyses, there was insufficient evidence that static arch type systematically modified the height-specific or overall condition-related response pattern. The analyses did not establish overall superiority of either the 12- or 15-mm configuration. Future studies should integrate dynamic arch characteristics, comfort, and longer-term adaptation.</p>","PeriodicalId":12716,"journal":{"name":"Frontiers in Sports and Active Living","volume":"8 ","pages":"1942713"},"PeriodicalIF":3.0000,"publicationDate":"2026-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13648250/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Sports and Active Living","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fspor.2026.1942713","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: A prior parameter-optimization study identified 9-15-mm support heights at 22%-26% infill as a candidate range for 3D-printed arch-support inserts, but whether responses within this range differ between runners with normal and high arches remains unclear. This arch-type-stratified secondary analysis compared shoe-ground interface loading under Single and 9-, 12-, and 15-mm support conditions at 24% infill and explored the temporal localization of condition-related differences during stance.
Methods: The primary balanced analysis included thirty male marathon runners (15 normal arch, 15 high arch), and a sensitivity analysis included all 55 eligible runners (40 normal arch, 15 high arch). A floor-mounted Footscan® system recorded shoe-ground pressure and regional force data. Primary outcomes were maximum regional peak pressure (MaxPP), maximum metatarsal-region peak pressure (MetaPP), midfoot force impulse fraction (MIF), heel force impulse fraction (HIF), and mediolateral impulse index (MLI). Prespecified comparisons used paired or Welch t-tests with Benjamini-Hochberg false-discovery-rate correction, complemented by Arch Type × Condition linear mixed-effects models and exploratory pointwise time-series analyses.
Results: Under Single, none of the five primary outcomes differed between arch groups after FDR correction. In the primary balanced analysis, relative to Single, FDR-supported differences were concentrated in impulse-distribution measures: MIF increased by 17.9%-19.5% in normal-arch runners under 12-24 and 15-24 and by 18.0%-23.0% in high-arch runners across all three supports, whereas MLI decreased by 14.0%-24.0% and 12.0%-19.7%, respectively. In this analysis, no MaxPP or MetaPP comparison met the FDR threshold. In normal arches, MIF was 7.4% higher under 12-24 than 9-24 (q = 0.041) and 9.0% higher under 15-24 than 9-24 (q = 0.003); no direct support-condition comparison was FDR-significant in high arches. Neither the 15 between-arch change comparisons nor the five Arch Type × Condition interactions reached FDR significance in the balanced analysis, and the same 0/15 and 0/5 pattern was retained in the full-cohort sensitivity analysis. Exploratory temporal differences were localized mainly to early-to-middle stance for midfoot force share and middle-to-late stance for dynamic MLI.
Conclusion: In the primary balanced analysis, condition-related differences were expressed more consistently in MIF and MLI than in peak-pressure measures. Across the balanced and full-cohort analyses, there was insufficient evidence that static arch type systematically modified the height-specific or overall condition-related response pattern. The analyses did not establish overall superiority of either the 12- or 15-mm configuration. Future studies should integrate dynamic arch characteristics, comfort, and longer-term adaptation.