Cuffless Blood Pressure Estimation From Wearable Photoplethysmography and Windkessel Model-Regularized Learning Approach

IF 2.4 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
IEEE Sensors Letters Pub Date : 2026-10-01 Epub Date: 2026-08-14 DOI:10.1109/LSENS.2026.3724173
Adeeba Khan;Swarubini P J;Ryunosuke Kirita;Tomohiko Igasaki;Nagarajan Ganapathy
{"title":"Cuffless Blood Pressure Estimation From Wearable Photoplethysmography and Windkessel Model-Regularized Learning Approach","authors":"Adeeba Khan;Swarubini P J;Ryunosuke Kirita;Tomohiko Igasaki;Nagarajan Ganapathy","doi":"10.1109/LSENS.2026.3724173","DOIUrl":null,"url":null,"abstract":"Wearable cuffless blood pressure (BP) monitoring using photoplethysmography (PPG) sensors has gained attention for noninvasive hemodynamic assessment. However, most deep learning methods are purely data-driven and lack physiological consistency. This study presents a physiology-informed learning framework for PPG-based BP estimation by integrating cardiovascular dynamics derived from the Windkessel model into a bounded loss function. The proposed framework incorporates physiological constraints by enforcing exponentially decaying arterial pressure using a PPG-derived diastolic time constant. PPG signals from ten healthy subjects were collected using a wearable finger-based sensor during rest, affective stimulation, and Stroop test conditions to introduce variability. The system complies with Association for the Advancement of Medical Instrumentation standards, achieving a mean absolute error of 2.90 <inline-formula><tex-math>$\\pm$</tex-math></inline-formula> 1.20 mmHg for DBP and 4.10 <inline-formula><tex-math>$\\pm$</tex-math></inline-formula> 1.41 mmHg for SBP. These results, from a small, homogeneous cohort, support feasibility of physiology-informed learning and motivate validation on larger, diverse populations toward clinical translation.","PeriodicalId":13014,"journal":{"name":"IEEE Sensors Letters","volume":"10 10","pages":"6011804-6011804"},"PeriodicalIF":2.4000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11656320/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Wearable cuffless blood pressure (BP) monitoring using photoplethysmography (PPG) sensors has gained attention for noninvasive hemodynamic assessment. However, most deep learning methods are purely data-driven and lack physiological consistency. This study presents a physiology-informed learning framework for PPG-based BP estimation by integrating cardiovascular dynamics derived from the Windkessel model into a bounded loss function. The proposed framework incorporates physiological constraints by enforcing exponentially decaying arterial pressure using a PPG-derived diastolic time constant. PPG signals from ten healthy subjects were collected using a wearable finger-based sensor during rest, affective stimulation, and Stroop test conditions to introduce variability. The system complies with Association for the Advancement of Medical Instrumentation standards, achieving a mean absolute error of 2.90 $\pm$ 1.20 mmHg for DBP and 4.10 $\pm$ 1.41 mmHg for SBP. These results, from a small, homogeneous cohort, support feasibility of physiology-informed learning and motivate validation on larger, diverse populations toward clinical translation.
基于可穿戴光电容积脉搏波和Windkessel模型的无袖带血压估计-正则化学习方法
使用光容积脉搏波(PPG)传感器进行可穿戴式无袖带血压监测已成为一种无创血流动力学评估方法。然而,大多数深度学习方法纯粹是数据驱动的,缺乏生理一致性。本研究通过将Windkessel模型导出的心血管动力学集成到有界损失函数中,提出了一个基于ppg的BP估计的生理信息学习框架。提出的框架结合了生理约束,通过使用ppg衍生的舒张时间常数强制指数衰减动脉压。10名健康受试者在休息、情感刺激和Stroop测试条件下使用可穿戴式手指传感器收集PPG信号以引入可变性。该系统符合美国医疗器械进步协会的标准,舒张血压的平均绝对误差为2.90 $\pm$ 1.20 mmHg,收缩压的平均绝对误差为4.10 $\pm$ 1.41 mmHg。这些结果来自一个小的、同质的队列,支持生理学知识学习的可行性,并激励在更大的、不同的人群中进行临床翻译的验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Sensors Letters
IEEE Sensors Letters Engineering-Electrical and Electronic Engineering
CiteScore
3.50
自引率
7.10%
发文量
194
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书