Mechanically Isolating and Self-Monitoring Low-Cost Phononic Connectors for Amorphous Wearable Bioelectronics

IF 2.4 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
IEEE Sensors Letters Pub Date : 2026-10-01 Epub Date: 2026-09-16 DOI:10.1109/LSENS.2026.3734690
Alessandro Ascani Orsini;Daniel Guo;Haoyu Xu;Yijun Lai;Chang Liu;Mengke Wang;Sung-Min Cho;Nitish Thakor
{"title":"Mechanically Isolating and Self-Monitoring Low-Cost Phononic Connectors for Amorphous Wearable Bioelectronics","authors":"Alessandro Ascani Orsini;Daniel Guo;Haoyu Xu;Yijun Lai;Chang Liu;Mengke Wang;Sung-Min Cho;Nitish Thakor","doi":"10.1109/LSENS.2026.3734690","DOIUrl":null,"url":null,"abstract":"Wearable bioelectronic systems typically employ uniform flexible interconnects that mechanically couple distributed electrodes, allowing motion at one site to perturb contact pressure and signal quality elsewhere. This work introduces a connector inspired by phononics that reduces force transmission between electrodes while self-monitoring deformation for artifact labeling. By spatially varying the pitch of serpentine interconnects, the connector redistributes strain and mechanically isolates adjacent sensing sites. Embedded strain sensors provide a direct electrical readout of connector deformation and enable identification and timing of motion-induced disturbances at their mechanical origin. Mechanical testing showed reduced effective stiffness (7× lower spring constant), localized strain, and a shifted transmissibility band (1–3 Hz) that decreased force transfer to the electrode, while synchronized strain-gauge signals with electrophysiological recordings aligned with and predicted motion-induced disturbances (<italic>p</i> < 0.005). Together, these findings indicate the phononic design influences recording stability while allowing mechanical disturbances to be measured rather than inferred.","PeriodicalId":13014,"journal":{"name":"IEEE Sensors Letters","volume":"10 10","pages":"6500304-6500304"},"PeriodicalIF":2.4000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11692595/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/16 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Wearable bioelectronic systems typically employ uniform flexible interconnects that mechanically couple distributed electrodes, allowing motion at one site to perturb contact pressure and signal quality elsewhere. This work introduces a connector inspired by phononics that reduces force transmission between electrodes while self-monitoring deformation for artifact labeling. By spatially varying the pitch of serpentine interconnects, the connector redistributes strain and mechanically isolates adjacent sensing sites. Embedded strain sensors provide a direct electrical readout of connector deformation and enable identification and timing of motion-induced disturbances at their mechanical origin. Mechanical testing showed reduced effective stiffness (7× lower spring constant), localized strain, and a shifted transmissibility band (1–3 Hz) that decreased force transfer to the electrode, while synchronized strain-gauge signals with electrophysiological recordings aligned with and predicted motion-induced disturbances (p < 0.005). Together, these findings indicate the phononic design influences recording stability while allowing mechanical disturbances to be measured rather than inferred.
用于非晶可穿戴生物电子学的机械隔离和自我监测低成本声子连接器
可穿戴生物电子系统通常采用均匀的柔性互连,机械耦合分布电极,允许一个位置的运动干扰其他位置的接触压力和信号质量。这项工作介绍了一种受传声学启发的连接器,它可以减少电极之间的力传递,同时自我监测工件标签的变形。通过在空间上改变蛇形互连的节距,连接器重新分配应变并机械地隔离相邻的传感点。嵌入式应变传感器提供连接器变形的直接电子读数,并能够在其机械起源处识别和定时运动引起的干扰。力学测试表明,有效刚度降低(弹簧常数降低7倍),局部应变和透射率带移位(1-3 Hz)减少了向电极的力传递,而同步应变测量信号与电生理记录一致,并预测了运动引起的干扰(p < 0.005)。总之,这些发现表明声子设计影响记录稳定性,同时允许测量而不是推断机械干扰。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Sensors Letters
IEEE Sensors Letters Engineering-Electrical and Electronic Engineering
CiteScore
3.50
自引率
7.10%
发文量
194
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书