A Delta-Based SAR ROIC for Low-Voltage Wide-Input-Range Gas Sensor Readout

IF 2.4 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
IEEE Sensors Letters Pub Date : 2026-10-01 Epub Date: 2026-09-07 DOI:10.1109/LSENS.2026.3731262
Soon-Kyu Kwon;Jun-Nyeong Kim;Hyeon-June Kim
{"title":"A Delta-Based SAR ROIC for Low-Voltage Wide-Input-Range Gas Sensor Readout","authors":"Soon-Kyu Kwon;Jun-Nyeong Kim;Hyeon-June Kim","doi":"10.1109/LSENS.2026.3731262","DOIUrl":null,"url":null,"abstract":"This letter presents a delta-conversion successive approximation register (SAR)-based readout integrated circuit (ROIC) for low-power gas sensing with large sensor output swings. Instead of digitizing the absolute sensor output, the proposed architecture converts only the intersample difference using back-switching-based residue generation. It compresses the effective conversion range by generating the intersample residue inside the capacitor digital-to-analog converter, enabling low-voltage operation while directly sampling the full sensor output. The SAR conversion is further limited to a small least significant bit range, reducing comparison cycles and switching activity. A 10 bit prototype was fabricated in a 0.18 <italic>μ</i>m CMOS process and operates at 1.2 V. The proposed ROIC consumes 89.3 <italic>μ</i>W, achieving a 57.5% reduction compared to a conventional full-range SAR analog-to-digital converter, while reducing comparator power from 70% to 2.8%. The measured results show a maximum reconstruction error of 1.2 mV, relative error below 0.09%. These results demonstrate accurate signal reconstruction with improved energy efficiency for low-power gas monitoring systems.","PeriodicalId":13014,"journal":{"name":"IEEE Sensors Letters","volume":"10 10","pages":"5000904-5000907"},"PeriodicalIF":2.4000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11682752/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/7 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

This letter presents a delta-conversion successive approximation register (SAR)-based readout integrated circuit (ROIC) for low-power gas sensing with large sensor output swings. Instead of digitizing the absolute sensor output, the proposed architecture converts only the intersample difference using back-switching-based residue generation. It compresses the effective conversion range by generating the intersample residue inside the capacitor digital-to-analog converter, enabling low-voltage operation while directly sampling the full sensor output. The SAR conversion is further limited to a small least significant bit range, reducing comparison cycles and switching activity. A 10 bit prototype was fabricated in a 0.18 μm CMOS process and operates at 1.2 V. The proposed ROIC consumes 89.3 μW, achieving a 57.5% reduction compared to a conventional full-range SAR analog-to-digital converter, while reducing comparator power from 70% to 2.8%. The measured results show a maximum reconstruction error of 1.2 mV, relative error below 0.09%. These results demonstrate accurate signal reconstruction with improved energy efficiency for low-power gas monitoring systems.
基于delta的低电压宽输入范围气体传感器读出SAR ROIC
本文介绍了一种基于增量转换连续逼近寄存器(SAR)的读出集成电路(ROIC),用于具有大传感器输出波动的低功耗气体传感。所提出的架构不是数字化传感器的绝对输出,而是使用基于后置开关的残差生成来转换采样间差分。它通过在电容数模转换器内部产生采样间残留来压缩有效转换范围,从而在直接采样整个传感器输出的同时实现低压操作。SAR转换进一步限制在最小有效位范围内,减少了比较周期和切换活动。采用0.18 μm CMOS工艺制作了10位原型,工作电压为1.2 V。所提出的ROIC功耗为89.3 μW,与传统全量程SAR模数转换器相比降低57.5%,同时将比较器功耗从70%降低到2.8%。测量结果表明,最大重构误差为1.2 mV,相对误差小于0.09%。这些结果证明了低功耗气体监测系统在提高能源效率的情况下可以实现准确的信号重建。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Sensors Letters
IEEE Sensors Letters Engineering-Electrical and Electronic Engineering
CiteScore
3.50
自引率
7.10%
发文量
194
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书