Self-Absorption Correction Method Based on Blackbody Radiation Referenced-Particle Swarm Optimization

IF 0.7 4区 化学 Q4 SPECTROSCOPY
Jingjun Lin, Nanqi Ruan, Jiangfei Yang, Yutao Huang, Xiaomei Lina
{"title":"Self-Absorption Correction Method Based on Blackbody Radiation Referenced-Particle Swarm Optimization","authors":"Jingjun Lin,&nbsp;Nanqi Ruan,&nbsp;Jiangfei Yang,&nbsp;Yutao Huang,&nbsp;Xiaomei Lina","doi":"10.1007/s10812-026-02168-0","DOIUrl":null,"url":null,"abstract":"<p>Enhancing the precision of quantitative analysis in calibration-free laser-induced breakdown spectroscopy (CFLIBS) requires a thorough understanding of self-absorption correction techniques. This work introduces blackbody radiation referenced-particle swarm optimization (BRR-PSO) as a self-absorption correction technique. This method compares the measured spectral intensity to blackbody radiation using Particle Swarm Optimization (PSO) to enable quick self-absorption correction. Corrected spectral intensities are obtained by iteratively refining initial values using the PSO optimization technique. Experiments were conducted on alloy samples to verify the efficacy of this method. The results show that as compared to the traditional CF-LIBS methodology, the CF-LIBS with the BRR-PSO method significantly improves the mean relative error (MRE). The MRE decreased from a range of ~27.35–43.75% to ~5.14–7.86% for the six alloy samples. For Fe I, Mn I, Cr I, Mo I, C I, and Si I, the Boltzmann plot linear fi t coefficient of determination (<i>R</i><sup>2</sup>) increased from 0.9220, 0.8050, 0.8801, 0.7102, 0.9064, and 0.9146 to 0.9887, 0.9813, 0.9662, 0.9809, 0.9542, and 0.9459, respectively. By greatly increasing both quantitative analysis accuracy and adaptability, the CF-LIBS approach improved with BRR-PSO demonstrating a clear advantage over conventional CF-LIBS. This development makes CF-LIBS technology more dependable and adaptable for real-world analysis, which is crucial for extending its useful applications.</p>","PeriodicalId":609,"journal":{"name":"Journal of Applied Spectroscopy","volume":"93 4","pages":"944 - 955"},"PeriodicalIF":0.7000,"publicationDate":"2026-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s10812-026-02168-0","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 0

Abstract

Enhancing the precision of quantitative analysis in calibration-free laser-induced breakdown spectroscopy (CFLIBS) requires a thorough understanding of self-absorption correction techniques. This work introduces blackbody radiation referenced-particle swarm optimization (BRR-PSO) as a self-absorption correction technique. This method compares the measured spectral intensity to blackbody radiation using Particle Swarm Optimization (PSO) to enable quick self-absorption correction. Corrected spectral intensities are obtained by iteratively refining initial values using the PSO optimization technique. Experiments were conducted on alloy samples to verify the efficacy of this method. The results show that as compared to the traditional CF-LIBS methodology, the CF-LIBS with the BRR-PSO method significantly improves the mean relative error (MRE). The MRE decreased from a range of ~27.35–43.75% to ~5.14–7.86% for the six alloy samples. For Fe I, Mn I, Cr I, Mo I, C I, and Si I, the Boltzmann plot linear fi t coefficient of determination (R2) increased from 0.9220, 0.8050, 0.8801, 0.7102, 0.9064, and 0.9146 to 0.9887, 0.9813, 0.9662, 0.9809, 0.9542, and 0.9459, respectively. By greatly increasing both quantitative analysis accuracy and adaptability, the CF-LIBS approach improved with BRR-PSO demonstrating a clear advantage over conventional CF-LIBS. This development makes CF-LIBS technology more dependable and adaptable for real-world analysis, which is crucial for extending its useful applications.

基于黑体辐射参考粒子群优化的自吸收校正方法
提高免校准激光诱导击穿光谱(CFLIBS)定量分析的精度需要对自吸收校正技术有深入的了解。本文介绍了黑体辐射参考粒子群优化(BRR-PSO)作为一种自吸收校正技术。该方法使用粒子群优化(PSO)将测量的光谱强度与黑体辐射进行比较,从而实现快速自吸收校正。利用粒子群优化技术对初始值进行迭代细化,得到校正后的光谱强度。在合金样品上进行了实验,验证了该方法的有效性。结果表明,与传统的CF-LIBS方法相比,BRR-PSO方法显著提高了CF-LIBS的平均相对误差(MRE)。6种合金试样的MRE从~27.35 ~ 43.75%降至~5.14 ~ 7.86%。Fe I、Mn I、Cr I、Mo I、C I和Si I的Boltzmann图线性拟合系数(R2)分别从0.9220、0.8050、0.8801、0.7102、0.9064和0.9146增加到0.9887、0.9813、0.9662、0.9809、0.9542和0.9459。通过大大提高定量分析的准确性和适应性,BRR-PSO改进了CF-LIBS方法,比传统的CF-LIBS具有明显的优势。这一发展使得CF-LIBS技术更加可靠和适用于现实世界的分析,这对于扩展其有用的应用至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.30
自引率
14.30%
发文量
145
审稿时长
2.5 months
期刊介绍: Journal of Applied Spectroscopy reports on many key applications of spectroscopy in chemistry, physics, metallurgy, and biology. An increasing number of papers focus on the theory of lasers, as well as the tremendous potential for the practical applications of lasers in numerous fields and industries.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书