{"title":"Two-Step Broadband Equivalent Circuit Modeling Method for Power Transformer Winding Based on Frequency Response Analysis and Bayesian Optimization","authors":"Yu Chen;Jiangnan Liu;Yuxuan Ding;Yaping Du;Binghao Li;Chenguo Yao;Zhongyong Zhao","doi":"10.1109/TDEI.2025.3635100","DOIUrl":null,"url":null,"abstract":"Frequency response analysis (FRA) is a well-established technique to detect transformer winding deformation faults. Its diagnostic application is based on the principle that a transformer winding can be represented by an equivalent circuit consisting of resistors, inductors, and capacitors. However, rapidly obtaining an accurate and physically meaningful broadband equivalent circuit model for windings remains challenging, limiting both the understanding of fault mechanisms and the generation of data for data-driven fault diagnosis methods. To address these difficulties, this study proposes a two-step broadband equivalent circuit modeling method for the transformer winding based on FRA and Bayesian optimization (BO), considering long-distance mutual inductances and capacitances. The proposed method is validated in a specially designed 10-kV power transformer. Subsequently, two kinds of winding deformation faults, including interdisk short circuits (IDSCs) and disk space variations (DSVs), are simulated on the basis of the built model and compared with the experimental FRA data. The validation results confirm the accuracy and effectiveness of the proposed method in the construction of the equivalent winding circuit.","PeriodicalId":13247,"journal":{"name":"IEEE Transactions on Dielectrics and Electrical Insulation","volume":"33 5","pages":"3910-3919"},"PeriodicalIF":3.3000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Dielectrics and Electrical Insulation","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11262213/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/20 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Frequency response analysis (FRA) is a well-established technique to detect transformer winding deformation faults. Its diagnostic application is based on the principle that a transformer winding can be represented by an equivalent circuit consisting of resistors, inductors, and capacitors. However, rapidly obtaining an accurate and physically meaningful broadband equivalent circuit model for windings remains challenging, limiting both the understanding of fault mechanisms and the generation of data for data-driven fault diagnosis methods. To address these difficulties, this study proposes a two-step broadband equivalent circuit modeling method for the transformer winding based on FRA and Bayesian optimization (BO), considering long-distance mutual inductances and capacitances. The proposed method is validated in a specially designed 10-kV power transformer. Subsequently, two kinds of winding deformation faults, including interdisk short circuits (IDSCs) and disk space variations (DSVs), are simulated on the basis of the built model and compared with the experimental FRA data. The validation results confirm the accuracy and effectiveness of the proposed method in the construction of the equivalent winding circuit.
期刊介绍:
Topics that are concerned with dielectric phenomena and measurements, with development and characterization of gaseous, vacuum, liquid and solid electrical insulating materials and systems; and with utilization of these materials in circuits and systems under condition of use.