{"title":"A Validation Method for UHF Partial Discharge Localization in Power Transformers Based on Pulse Injection","authors":"Zirui Wu;Cheng Pan;Zijun Pan;Qingdong Zhu;Hui Wang;Ju Tang","doi":"10.1109/TDEI.2026.3656146","DOIUrl":null,"url":null,"abstract":"Accurate localization of partial discharge (PD) in power transformers is critical for condition monitoring and fault prevention. However, localization algorithms are primarily validated through laboratory experiments or offline tests, making it difficult to assess their performance accurately in operational transformers. In this article, a method is proposed to evaluate the positioning accuracy of PD localization algorithms by injecting pulse current into an ultrahigh-frequency (UHF) sensor to simulate a PD source. The proposed method is first validated on an in-service 220-kV transformer equipped with six built-in UHF sensors. The results show that this method is safe, controllable, and capable of flexibly changing the location of PD. Furthermore, extensive experiments are conducted on another 220-kV transformer equipped with 18 built-in UHF sensors to systematically analyze the impact of sensor number and placement on the localization error of time difference of arrival (TDOA). It is found that increasing the number of sensors can reduce the likelihood of large positioning errors to some extent. However, for highly accurate positioning, the best result is achieved when using five or six sensors. In terms of sensor placement, TDOA-based localization is less robust when sensors are placed on the same side or in adjacent areas. Uniform placement on all sides of the transformer can improve robustness, but it is difficult to achieve a high accuracy of the positioning error within 0.5 m.","PeriodicalId":13247,"journal":{"name":"IEEE Transactions on Dielectrics and Electrical Insulation","volume":"33 5","pages":"3705-3712"},"PeriodicalIF":3.3000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Dielectrics and Electrical Insulation","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11358980/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/19 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Accurate localization of partial discharge (PD) in power transformers is critical for condition monitoring and fault prevention. However, localization algorithms are primarily validated through laboratory experiments or offline tests, making it difficult to assess their performance accurately in operational transformers. In this article, a method is proposed to evaluate the positioning accuracy of PD localization algorithms by injecting pulse current into an ultrahigh-frequency (UHF) sensor to simulate a PD source. The proposed method is first validated on an in-service 220-kV transformer equipped with six built-in UHF sensors. The results show that this method is safe, controllable, and capable of flexibly changing the location of PD. Furthermore, extensive experiments are conducted on another 220-kV transformer equipped with 18 built-in UHF sensors to systematically analyze the impact of sensor number and placement on the localization error of time difference of arrival (TDOA). It is found that increasing the number of sensors can reduce the likelihood of large positioning errors to some extent. However, for highly accurate positioning, the best result is achieved when using five or six sensors. In terms of sensor placement, TDOA-based localization is less robust when sensors are placed on the same side or in adjacent areas. Uniform placement on all sides of the transformer can improve robustness, but it is difficult to achieve a high accuracy of the positioning error within 0.5 m.
期刊介绍:
Topics that are concerned with dielectric phenomena and measurements, with development and characterization of gaseous, vacuum, liquid and solid electrical insulating materials and systems; and with utilization of these materials in circuits and systems under condition of use.