Simulation of Space Charge Distribution in the Insulator Under Negative DC Voltage and Its Impact on Ice Flashover Voltage

IF 3.3 3区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC
Yuyao Hu;Wentao Jia;Xingliang Jiang;Richang Xian;Qiang Zhou;Haitao Wu
{"title":"Simulation of Space Charge Distribution in the Insulator Under Negative DC Voltage and Its Impact on Ice Flashover Voltage","authors":"Yuyao Hu;Wentao Jia;Xingliang Jiang;Richang Xian;Qiang Zhou;Haitao Wu","doi":"10.1109/TDEI.2026.3656475","DOIUrl":null,"url":null,"abstract":"Space charges can reduce the flashover voltage of the insulators and adversely affect their normal operation. However, the research on space charges in the field of iced insulators remains scarce. This study took the FXBW-35/70 composite insulator as the research object, and a space charge distribution equation on the insulator surface under dc negative polarity voltage was derived. A 3-D simulation model was constructed to analyze the impacts of different voltage application time and voltage levels on electric field and space charge accumulation characteristics. The findings were further validated through natural icing experiments. The simulation results indicate that under negative dc voltage, negative charges predominantly accumulate on the lower surface of insulator sheds, while positive charges mainly gather on the upper surface. Space charge density initially increases rapidly and then approaches saturation as voltage application time extends, and it rises significantly with an increase in voltage level. The corresponding maximums of space charge densities are 5.46 and 9.1 mC/m<sup>3</sup>, respectively. Moreover, the influence of voltage level on space charge and water droplet trajectory is stronger than that of voltage application time. The accumulation of space charges exacerbates electric field distortion, elevating the maximum electric field strength of the insulator. Under the combined effects of applied voltage and space charges, a new discharge channel forms, ultimately leading to the extinction of the original arc. The flashover voltage of iced insulators exhibits a negative correlation with both voltage application time and voltage level. Based on this relationship, a multivariate fitting model for flashover voltage has been developed, with an average error of 7.3%. The space charge distribution is derived from simulation and validated indirectly through flashover experiments.","PeriodicalId":13247,"journal":{"name":"IEEE Transactions on Dielectrics and Electrical Insulation","volume":"33 5","pages":"3871-3881"},"PeriodicalIF":3.3000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Dielectrics and Electrical Insulation","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11359239/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/20 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Space charges can reduce the flashover voltage of the insulators and adversely affect their normal operation. However, the research on space charges in the field of iced insulators remains scarce. This study took the FXBW-35/70 composite insulator as the research object, and a space charge distribution equation on the insulator surface under dc negative polarity voltage was derived. A 3-D simulation model was constructed to analyze the impacts of different voltage application time and voltage levels on electric field and space charge accumulation characteristics. The findings were further validated through natural icing experiments. The simulation results indicate that under negative dc voltage, negative charges predominantly accumulate on the lower surface of insulator sheds, while positive charges mainly gather on the upper surface. Space charge density initially increases rapidly and then approaches saturation as voltage application time extends, and it rises significantly with an increase in voltage level. The corresponding maximums of space charge densities are 5.46 and 9.1 mC/m3, respectively. Moreover, the influence of voltage level on space charge and water droplet trajectory is stronger than that of voltage application time. The accumulation of space charges exacerbates electric field distortion, elevating the maximum electric field strength of the insulator. Under the combined effects of applied voltage and space charges, a new discharge channel forms, ultimately leading to the extinction of the original arc. The flashover voltage of iced insulators exhibits a negative correlation with both voltage application time and voltage level. Based on this relationship, a multivariate fitting model for flashover voltage has been developed, with an average error of 7.3%. The space charge distribution is derived from simulation and validated indirectly through flashover experiments.
负直流电压下绝缘子空间电荷分布的模拟及其对冰闪络电压的影响
空间电荷会降低绝缘子的闪络电压,对绝缘子的正常工作产生不利影响。然而,在冰冻绝缘子领域对空间电荷的研究仍然很少。本研究以FXBW-35/70复合绝缘子为研究对象,推导了直流负极性电压下绝缘子表面空间电荷分布方程。建立了三维仿真模型,分析了不同电压施加时间和电压水平对电场和空间电荷积累特性的影响。通过自然结冰实验进一步验证了研究结果。仿真结果表明,在直流负电压下,绝缘子棚内的负电荷主要集中在下表面,而正电荷主要集中在上表面。随着电压施加时间的延长,空间电荷密度先迅速增加,然后趋于饱和,随着电压水平的增加,空间电荷密度显著上升。相应的空间电荷密度最大值分别为5.46和9.1 mC/m3。电压水平对空间电荷和水滴轨迹的影响强于施加电压时间。空间电荷的积累加剧了电场畸变,提高了绝缘子的最大电场强度。在外加电压和空间电荷的共同作用下,形成新的放电通道,最终导致原电弧熄灭。覆冰绝缘子的闪络电压与施加电压的时间和电压水平呈负相关。基于这一关系,建立了闪络电压的多元拟合模型,平均误差为7.3%。空间电荷分布由仿真得到,并通过闪络实验间接验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Dielectrics and Electrical Insulation
IEEE Transactions on Dielectrics and Electrical Insulation 工程技术-工程:电子与电气
CiteScore
6.00
自引率
22.60%
发文量
309
审稿时长
5.2 months
期刊介绍: Topics that are concerned with dielectric phenomena and measurements, with development and characterization of gaseous, vacuum, liquid and solid electrical insulating materials and systems; and with utilization of these materials in circuits and systems under condition of use.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书