An Advanced Detection Method for Assessing Aging State of Composite Insulators Under Pollution Cover

IF 3.3 3区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC
Yihan Fan;Yujun Guo;Yang Liu;Yuan Ou;Song Xiao;Xueqin Zhang;Guangning Wu
{"title":"An Advanced Detection Method for Assessing Aging State of Composite Insulators Under Pollution Cover","authors":"Yihan Fan;Yujun Guo;Yang Liu;Yuan Ou;Song Xiao;Xueqin Zhang;Guangning Wu","doi":"10.1109/TDEI.2026.3719608","DOIUrl":null,"url":null,"abstract":"Ultrahigh voltage direct current (UHVDC) converter stations are crucial components of future power systems. However, composite post insulators, which are essential to the functionality of those stations, are susceptible to issues such as contamination deposition and aging due to exposure to ultraviolet radiation and atmospheric pollution. These problems can lead to flashover, reduced hydrophobicity, increased leakage current (LC), and pose operational risks. This article utilizes hyperspectral imaging (HSI) technology to detect insulator aging under polluted conditions. By analyzing the spectral similarities of insulators before and after cleaning, a spectral difference model is developed, extracting 113 characteristic bands indicative of aging. To reduce complexity, principal component analysis (PCA) is applied for dimensionality reduction, with PC1 (96.54% contribution) used as the dataset. The least squares support vector machine (LSSVM) algorithm, adapted for large-scale data processing, is employed as the classification model and optimized using improved Harris hawks optimization (IHHO), which identifies optimal hyperparameters (<inline-formula> <tex-math>${C} =257.002$ </tex-math></inline-formula>, <inline-formula> <tex-math>${g} = 0.141$ </tex-math></inline-formula>). The performance of the PCA-IHHO-LSSVM model is evaluated against five other classification algorithms, showing the best accuracy (98.07%) and computation time (1.935 s). The model is then used for visual assessment of insulator aging states, contributing to the identification of operational risks and ensuring the safe and stable transmission of energy in UHVDC converter stations.","PeriodicalId":13247,"journal":{"name":"IEEE Transactions on Dielectrics and Electrical Insulation","volume":"33 5","pages":"3891-3900"},"PeriodicalIF":3.3000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Dielectrics and Electrical Insulation","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11640807/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/3 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Ultrahigh voltage direct current (UHVDC) converter stations are crucial components of future power systems. However, composite post insulators, which are essential to the functionality of those stations, are susceptible to issues such as contamination deposition and aging due to exposure to ultraviolet radiation and atmospheric pollution. These problems can lead to flashover, reduced hydrophobicity, increased leakage current (LC), and pose operational risks. This article utilizes hyperspectral imaging (HSI) technology to detect insulator aging under polluted conditions. By analyzing the spectral similarities of insulators before and after cleaning, a spectral difference model is developed, extracting 113 characteristic bands indicative of aging. To reduce complexity, principal component analysis (PCA) is applied for dimensionality reduction, with PC1 (96.54% contribution) used as the dataset. The least squares support vector machine (LSSVM) algorithm, adapted for large-scale data processing, is employed as the classification model and optimized using improved Harris hawks optimization (IHHO), which identifies optimal hyperparameters ( ${C} =257.002$ , ${g} = 0.141$ ). The performance of the PCA-IHHO-LSSVM model is evaluated against five other classification algorithms, showing the best accuracy (98.07%) and computation time (1.935 s). The model is then used for visual assessment of insulator aging states, contributing to the identification of operational risks and ensuring the safe and stable transmission of energy in UHVDC converter stations.
污盖下复合绝缘子老化状态的一种先进检测方法
特高压直流(UHVDC)换流站是未来电力系统的重要组成部分。但是,对这些站的功能至关重要的复合柱绝缘子,由于暴露于紫外线辐射和大气污染,容易受到诸如污染沉积和老化等问题的影响。这些问题可能导致闪络、疏水性降低、泄漏电流(LC)增加,并带来操作风险。本文利用高光谱成像(HSI)技术检测污染条件下绝缘子的老化。通过分析清洗前后绝缘子的光谱相似度,建立了光谱差异模型,提取了113条指示老化的特征波段。为了降低复杂性,采用主成分分析(PCA)进行降维,以PC1(贡献96.54%)作为数据集。采用适用于大规模数据处理的最小二乘支持向量机(LSSVM)算法作为分类模型,采用改进的哈里斯鹰优化(IHHO)算法进行优化,识别出最优超参数(${C} =257.002$, ${g} = 0.141$)。将PCA-IHHO-LSSVM模型的性能与其他5种分类算法进行比较,结果表明PCA-IHHO-LSSVM模型的准确率为98.07%,计算时间为1.935 s。将该模型用于绝缘子老化状态的可视化评估,有助于识别运行风险,确保特高压直流换流站的安全稳定输电。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Dielectrics and Electrical Insulation
IEEE Transactions on Dielectrics and Electrical Insulation 工程技术-工程:电子与电气
CiteScore
6.00
自引率
22.60%
发文量
309
审稿时长
5.2 months
期刊介绍: Topics that are concerned with dielectric phenomena and measurements, with development and characterization of gaseous, vacuum, liquid and solid electrical insulating materials and systems; and with utilization of these materials in circuits and systems under condition of use.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书