Evaluation of tooth sensitivity and whitening effects of tooth whitening agents containing calcium, hydroxyapatite and fluoride.

IF 2.6 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Betül Tokat, Soley Arslan
{"title":"Evaluation of tooth sensitivity and whitening effects of tooth whitening agents containing calcium, hydroxyapatite and fluoride.","authors":"Betül Tokat, Soley Arslan","doi":"10.1007/s10266-026-01565-3","DOIUrl":null,"url":null,"abstract":"<p><p>This randomized clinical trial evaluated the effects of hydrogen peroxide (HP)-based whitening agents containing calcium, hydroxyapatite, and fluoride on color change (ΔE₀₀), whiteness change (ΔWID), and post-whitening tooth sensitivity (TS). Sixty participants were randomly allocated to three groups (n = 20) and treated with different in-office whitening systems: Opalescence Boost (40% HP and fluoride), Whiteness HP Blue (35% HP and calcium), and Biowhiten ProOffice PowerHP (18% HP and hydroxyapatite). Color change was measured spectrophotometrically before treatment, immediately after treatment, and at 1, 2, 4, 8, and 16 weeks, as well as at 6 months and 1 year. Tooth sensitivity was assessed using the Numerical Rating Scale (NRS). Patient satisfaction was also evaluated using a questionnaire. ΔE₀₀ values showed significant differences among the groups at all evaluation periods except immediately after treatment and at 1 year (p < 0.05). ΔWID values demonstrated significant differences at all time points except at 2 weeks, 4 weeks, and 1 year (p < 0.05). Immediately after treatment, NRS scores were significantly lower in the HP18 group than in the HP40 group (p < 0.05), while the HP35 group did not differ significantly from either group. No significant differences among the groups were observed at the subsequent time points (p > 0.05). No significant difference was found in patient satisfaction scores (p = 0.728). Despite differences in hydrogen peroxide concentration and formulation characteristics, all whitening systems provided comparable whitening efficacy, tooth sensitivity outcomes, and patient satisfaction after 1 year. The study was conducted prospectively and registered retrospectively at ClinicalTrials.gov (NCT06855940) on February 25, 2025.</p>","PeriodicalId":19390,"journal":{"name":"Odontology","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2026-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Odontology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10266-026-01565-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

This randomized clinical trial evaluated the effects of hydrogen peroxide (HP)-based whitening agents containing calcium, hydroxyapatite, and fluoride on color change (ΔE₀₀), whiteness change (ΔWID), and post-whitening tooth sensitivity (TS). Sixty participants were randomly allocated to three groups (n = 20) and treated with different in-office whitening systems: Opalescence Boost (40% HP and fluoride), Whiteness HP Blue (35% HP and calcium), and Biowhiten ProOffice PowerHP (18% HP and hydroxyapatite). Color change was measured spectrophotometrically before treatment, immediately after treatment, and at 1, 2, 4, 8, and 16 weeks, as well as at 6 months and 1 year. Tooth sensitivity was assessed using the Numerical Rating Scale (NRS). Patient satisfaction was also evaluated using a questionnaire. ΔE₀₀ values showed significant differences among the groups at all evaluation periods except immediately after treatment and at 1 year (p < 0.05). ΔWID values demonstrated significant differences at all time points except at 2 weeks, 4 weeks, and 1 year (p < 0.05). Immediately after treatment, NRS scores were significantly lower in the HP18 group than in the HP40 group (p < 0.05), while the HP35 group did not differ significantly from either group. No significant differences among the groups were observed at the subsequent time points (p > 0.05). No significant difference was found in patient satisfaction scores (p = 0.728). Despite differences in hydrogen peroxide concentration and formulation characteristics, all whitening systems provided comparable whitening efficacy, tooth sensitivity outcomes, and patient satisfaction after 1 year. The study was conducted prospectively and registered retrospectively at ClinicalTrials.gov (NCT06855940) on February 25, 2025.

含钙、羟基磷灰石和氟化物牙齿增白剂的牙齿敏感性和美白效果评价。
这项随机临床试验评估了含有钙、羟基磷灰石和氟化物的过氧化氢(HP)增白剂对牙齿颜色变化(ΔE₀0)、白度变化(ΔWID)和美白后牙齿敏感性(TS)的影响。60名参与者被随机分为三组(n = 20),并使用不同的办公室美白系统:Opalescence Boost (40% HP和氟化物),Whiteness HP Blue (35% HP和钙)和Biowhiten ProOffice PowerHP (18% HP和羟基磷灰石)。在治疗前、治疗后、1周、2周、4周、8周和16周以及6个月和1年时,分光光度法测量颜色变化。采用数值评定量表(NRS)评估牙齿敏感性。患者满意度也通过问卷进行评估。ΔE 0 0值在除治疗后立即和1年外的所有评估期组间均有显著差异(p 0.05)。患者满意度评分差异无统计学意义(p = 0.728)。尽管过氧化氢浓度和配方特性有所不同,但所有美白系统在1年后的美白功效、牙齿敏感性结果和患者满意度方面都具有可比性。该研究是前瞻性的,并于2025年2月25日在ClinicalTrials.gov (NCT06855940)进行回顾性注册。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Odontology
Odontology 医学-牙科与口腔外科
CiteScore
5.30
自引率
4.00%
发文量
91
审稿时长
>12 weeks
期刊介绍: The Journal Odontology covers all disciplines involved in the fields of dentistry and craniofacial research, including molecular studies related to oral health and disease. Peer-reviewed articles cover topics ranging from research on human dental pulp, to comparisons of analgesics in surgery, to analysis of biofilm properties of dental plaque.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书