Effect of Personalized Approach to CT Scan Length on Radiation Dose in Parathyroid SPECT/CT.

IF 1.5 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Anne H Thostrup, Natalie A Bebbington, Janne Frederiksen, Helle D Zacho
{"title":"Effect of Personalized Approach to CT Scan Length on Radiation Dose in Parathyroid SPECT/CT.","authors":"Anne H Thostrup, Natalie A Bebbington, Janne Frederiksen, Helle D Zacho","doi":"10.2967/jnmt.126.272875","DOIUrl":null,"url":null,"abstract":"<p><p>Parathyroid SPECT/CT is the standard examination for localization of hyperfunctioning parathyroid tissue before surgery for hyperparathyroidism. The effective dose (ED) delivered by CT comprises approximately one third of the radiation dose in this examination. Parathyroid SPECT/CT typically includes 1 CT covering the mediastinum because of the risk of ectopic adenomas. This study investigates whether the use of personalized CT (pCT) on the basis of SPECT images can reduce scan length and CT-derived ED, while maintaining the ability to detect ectopic adenomas, compared with full field-of-view (FOV) SPECT/CT. <b>Methods:</b> Patients with hyperparathyroidism who were referred for a clinical parathyroid SPECT/CT between May 2023 and June 2024 were prospectively included. Two observers (a technologist and junior physician) retrospectively determined pCT based on the non-attenuation-corrected SPECT images. The reduction in CT scan lengths compared with those of standard CT examinations was calculated. In a subgroup of patients, the reduction in ED was calculated. The detectability of ectopic adenomas was analyzed using imaging data from the full FOV SPECT/CT as the reference standard. <b>Results:</b> In total, 113 patients were included in the study. The standard examination found that 82 patients had at least 1 suspected lesion. Scan length was reduced by 60%-66% using pCT. No ectopic adenomas were missed on pCT. Subgroup analysis showed comparable reductions in CT scan length and CT-derived ED. <b>Conclusion:</b> Median CT scan length and median CT-derived ED was reduced by 60% when pCT was used for parathyroid SPECT/CT. pCT was implemented with minimal delay between SPECT and CT.</p>","PeriodicalId":16548,"journal":{"name":"Journal of nuclear medicine technology","volume":" ","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2026-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of nuclear medicine technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2967/jnmt.126.272875","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Parathyroid SPECT/CT is the standard examination for localization of hyperfunctioning parathyroid tissue before surgery for hyperparathyroidism. The effective dose (ED) delivered by CT comprises approximately one third of the radiation dose in this examination. Parathyroid SPECT/CT typically includes 1 CT covering the mediastinum because of the risk of ectopic adenomas. This study investigates whether the use of personalized CT (pCT) on the basis of SPECT images can reduce scan length and CT-derived ED, while maintaining the ability to detect ectopic adenomas, compared with full field-of-view (FOV) SPECT/CT. Methods: Patients with hyperparathyroidism who were referred for a clinical parathyroid SPECT/CT between May 2023 and June 2024 were prospectively included. Two observers (a technologist and junior physician) retrospectively determined pCT based on the non-attenuation-corrected SPECT images. The reduction in CT scan lengths compared with those of standard CT examinations was calculated. In a subgroup of patients, the reduction in ED was calculated. The detectability of ectopic adenomas was analyzed using imaging data from the full FOV SPECT/CT as the reference standard. Results: In total, 113 patients were included in the study. The standard examination found that 82 patients had at least 1 suspected lesion. Scan length was reduced by 60%-66% using pCT. No ectopic adenomas were missed on pCT. Subgroup analysis showed comparable reductions in CT scan length and CT-derived ED. Conclusion: Median CT scan length and median CT-derived ED was reduced by 60% when pCT was used for parathyroid SPECT/CT. pCT was implemented with minimal delay between SPECT and CT.

个性化CT扫描长度对甲状旁腺SPECT/CT放射剂量的影响。
甲状旁腺SPECT/CT是甲状旁腺功能亢进术前定位的标准检查。CT传递的有效剂量(ED)约占本检查中辐射剂量的三分之一。甲状旁腺SPECT/CT通常包括1个覆盖纵隔的CT,因为有异位腺瘤的风险。本研究探讨了与全视场(FOV) SPECT/CT相比,在SPECT图像的基础上使用个性化CT (pCT)是否可以减少扫描长度和CT衍生的ED,同时保持检测异位腺瘤的能力。方法:前瞻性纳入2023年5月至2024年6月间行临床甲状旁腺SPECT/CT检查的甲状旁腺功能亢进患者。两名观察员(一名技术人员和一名初级医生)回顾性地根据非衰减校正的SPECT图像确定了pCT。计算与标准CT检查相比,CT扫描长度的减少。在一个亚组患者中,计算ED的减少。以全视场SPECT/CT成像数据作为参考标准,分析异位腺瘤的可检出性。结果:共纳入113例患者。标准检查发现82例患者至少有1个疑似病变。亚组分析显示,CT扫描长度和CT衍生ED的减少幅度相当。结论:当pCT用于甲状旁腺SPECT/CT时,CT扫描中位长度和CT衍生ED的中位长度减少了60%。pCT在SPECT和CT之间的延迟最小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of nuclear medicine technology
Journal of nuclear medicine technology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.90
自引率
15.40%
发文量
57
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书