{"title":"Factors associated with successful initiation of labor analgesia using the dural puncture epidural technique: a retrospective cohort study.","authors":"Ayaka Kuwabata, Jun Takeshita, Kazuya Tachibana","doi":"10.1007/s00540-026-03918-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The dural puncture epidural (DPE) technique has been proposed as a modification of conventional epidural analgesia that may influence onset and block quality. However, factors associated with successful initiation of labor analgesia using the DPE technique remain unclear. We aimed to identify predictors for successful initiation of labor analgesia using the DPE technique.</p><p><strong>Methods: </strong>This retrospective study included parturients who received DPE for initiation of labor analgesia between April 2022 and March 2025. Success was defined as a composite outcome of epidural catheter placement within 15 min from initial skin puncture with the epidural needle and a numerical rating scale (NRS) pain score ≤ 3 recorded between 30 and 60 min after the first epidural bolus. Multivariable logistic regression was performed to identify independent predictors of success.</p><p><strong>Results: </strong>Among the 1037 parturients included in the analysis, success was achieved in 693 cases, whereas 344 were classified as failures. In the multivariable analysis, operator experience (per 10 procedures) (odds ratio 1.10, 95% confidence interval 1.04 to 1.15, P < 0.001), baseline NRS (P < 0.001), cervical dilation at initiation (P = 0.038), maternal age (P = 0.013), and spinal disorder (P = 0.034) were identified as independent predictors of success.</p><p><strong>Conclusion: </strong>Operator experience was independently associated with successful initiation of labor analgesia using the DPE technique and was the only factor associated with both procedural success and early analgesic effectiveness. Operator- and patient-related factors should be considered when predicting the likelihood of successful initiation of labor analgesia using the DPE technique.</p>","PeriodicalId":14997,"journal":{"name":"Journal of Anesthesia","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2026-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Anesthesia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00540-026-03918-2","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The dural puncture epidural (DPE) technique has been proposed as a modification of conventional epidural analgesia that may influence onset and block quality. However, factors associated with successful initiation of labor analgesia using the DPE technique remain unclear. We aimed to identify predictors for successful initiation of labor analgesia using the DPE technique.
Methods: This retrospective study included parturients who received DPE for initiation of labor analgesia between April 2022 and March 2025. Success was defined as a composite outcome of epidural catheter placement within 15 min from initial skin puncture with the epidural needle and a numerical rating scale (NRS) pain score ≤ 3 recorded between 30 and 60 min after the first epidural bolus. Multivariable logistic regression was performed to identify independent predictors of success.
Results: Among the 1037 parturients included in the analysis, success was achieved in 693 cases, whereas 344 were classified as failures. In the multivariable analysis, operator experience (per 10 procedures) (odds ratio 1.10, 95% confidence interval 1.04 to 1.15, P < 0.001), baseline NRS (P < 0.001), cervical dilation at initiation (P = 0.038), maternal age (P = 0.013), and spinal disorder (P = 0.034) were identified as independent predictors of success.
Conclusion: Operator experience was independently associated with successful initiation of labor analgesia using the DPE technique and was the only factor associated with both procedural success and early analgesic effectiveness. Operator- and patient-related factors should be considered when predicting the likelihood of successful initiation of labor analgesia using the DPE technique.
期刊介绍:
The Journal of Anesthesia is the official journal of the Japanese Society of Anesthesiologists. This journal publishes original articles, review articles, special articles, clinical reports, short communications, letters to the editor, and book and multimedia reviews. The editors welcome the submission of manuscripts devoted to anesthesia and related topics from any country of the world. Membership in the Society is not a prerequisite.
The Journal of Anesthesia (JA) welcomes case reports that show unique cases in perioperative medicine, intensive care, emergency medicine, and pain management.