Impact of Interelectrode Spacing on Ventricular Tachycardia Substrate Mapping: Insights Into 3-Dimensional Characteristics of the Arrhythmogenic Substrate.

IF 7.2 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Yuto Iioka, Yuki Komatsu, Yasutoshi Shinoda, Yuichi Hanaki, Yuka Oda, Yusuke Hayashi, Yoshihiro Harano, Yuki Matsuoka, Kojiro Ogawa, Akira Kimata, Hiro Yamasaki, Miyako Igarashi, Tomoko Ishizu, Akihiko Nogami
{"title":"Impact of Interelectrode Spacing on Ventricular Tachycardia Substrate Mapping: Insights Into 3-Dimensional Characteristics of the Arrhythmogenic Substrate.","authors":"Yuto Iioka, Yuki Komatsu, Yasutoshi Shinoda, Yuichi Hanaki, Yuka Oda, Yusuke Hayashi, Yoshihiro Harano, Yuki Matsuoka, Kojiro Ogawa, Akira Kimata, Hiro Yamasaki, Miyako Igarashi, Tomoko Ishizu, Akihiko Nogami","doi":"10.1016/j.jacep.2026.08.021","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Re-entrant ventricular tachycardia (VT) circuits often involve 3-dimensional activation across the endocardium, epicardium, and mid-myocardium, highlighting the importance of comprehensive substrate assessment. Wider interelectrode spacing may incorporate broader-field electrical components that are less apparent on conventional closely spaced recordings.</p><p><strong>Objectives: </strong>This study sought to investigate the electrophysiological impact of interelectrode spacing on substrate mapping and its potential implications for 3-dimensional features of VT substrate.</p><p><strong>Methods: </strong>Sixty-eight high-density substrate maps from 35 patients undergoing catheter ablation for scar-related VT were retrospectively analyzed. Closely spaced (2-mm) and widely spaced (8-mm) bipolar electrograms were simultaneously acquired using a decapolar catheter and used to generate closely and widely spaced bipolar electrode maps (CEM and WEM).</p><p><strong>Results: </strong>Compared with CEM, WEM, which incorporates a greater contribution of far-field components, demonstrated higher bipolar amplitudes, a greater prevalence of multicomponent electrograms, and a lower prevalence of split potentials (all P < 0.01). Lines of block delineated by split potentials on CEM were frequently attenuated or no longer apparent on WEM because the corresponding electrograms appeared fragmented and lacked a distinct split configuration. In an exploratory analysis of 6 VTs with evaluable activation maps, activation gaps were larger with closely than widely spaced bipolar mapping (32.5% vs 20.0%; P = 0.03). In 4 VTs, widely spaced recordings identified diastolic or presystolic far-field potentials not evident with closely spaced recordings.</p><p><strong>Conclusions: </strong>Widely spaced bipolar electrograms may provide complementary functional information beyond that obtained with conventional near-field recordings by incorporating broader-field electrical components, thereby offering additional insight into the potential 3-dimensional characteristics of the arrhythmogenic substrate.</p>","PeriodicalId":14573,"journal":{"name":"JACC. Clinical electrophysiology","volume":" ","pages":""},"PeriodicalIF":7.2000,"publicationDate":"2026-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JACC. Clinical electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jacep.2026.08.021","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Re-entrant ventricular tachycardia (VT) circuits often involve 3-dimensional activation across the endocardium, epicardium, and mid-myocardium, highlighting the importance of comprehensive substrate assessment. Wider interelectrode spacing may incorporate broader-field electrical components that are less apparent on conventional closely spaced recordings.

Objectives: This study sought to investigate the electrophysiological impact of interelectrode spacing on substrate mapping and its potential implications for 3-dimensional features of VT substrate.

Methods: Sixty-eight high-density substrate maps from 35 patients undergoing catheter ablation for scar-related VT were retrospectively analyzed. Closely spaced (2-mm) and widely spaced (8-mm) bipolar electrograms were simultaneously acquired using a decapolar catheter and used to generate closely and widely spaced bipolar electrode maps (CEM and WEM).

Results: Compared with CEM, WEM, which incorporates a greater contribution of far-field components, demonstrated higher bipolar amplitudes, a greater prevalence of multicomponent electrograms, and a lower prevalence of split potentials (all P < 0.01). Lines of block delineated by split potentials on CEM were frequently attenuated or no longer apparent on WEM because the corresponding electrograms appeared fragmented and lacked a distinct split configuration. In an exploratory analysis of 6 VTs with evaluable activation maps, activation gaps were larger with closely than widely spaced bipolar mapping (32.5% vs 20.0%; P = 0.03). In 4 VTs, widely spaced recordings identified diastolic or presystolic far-field potentials not evident with closely spaced recordings.

Conclusions: Widely spaced bipolar electrograms may provide complementary functional information beyond that obtained with conventional near-field recordings by incorporating broader-field electrical components, thereby offering additional insight into the potential 3-dimensional characteristics of the arrhythmogenic substrate.

电极间距对室性心动过速底物定位的影响:对致心律失常底物三维特征的洞察。
背景:再入性室性心动过速(VT)电路通常涉及穿过心内膜、心外膜和心肌中部的三维激活,强调了全面底物评估的重要性。更宽的电极间距可以包含更宽的电场元件,这在传统的紧密间隔记录中不太明显。目的:本研究旨在探讨电极间距对基底映射的电生理影响及其对基底三维特征的潜在影响。方法:回顾性分析35例接受导管消融治疗的瘢痕相关性室性心动过速患者的68张高密度底物图。使用去极导管同时获得紧密间隔(2mm)和广泛间隔(8mm)的双极电图,并用于生成紧密和广泛间隔的双极电极图(CEM和WEM)。结果:与CEM相比,远场分量贡献更大的WEM表现出更高的双极振幅,更高的多分量电图患病率,更低的分裂电位患病率(P < 0.01)。在CEM上由分裂电位描绘的块线经常衰减或在WEM上不再明显,因为相应的电图呈现碎片状,缺乏明显的分裂结构。在6个具有可评估激活图的vt的探索性分析中,近间隔双极映射比宽间隔双极映射的激活间隙更大(32.5%比20.0%;P = 0.03)。在4个VTs中,宽间隔记录识别出舒张或收缩前远场电位,而窄间隔记录不明显。结论:宽间距双极电图可以提供比传统近场记录所获得的更补充的功能信息,通过结合更宽场的电元件,从而提供对心律失常底物潜在三维特征的额外见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JACC. Clinical electrophysiology
JACC. Clinical electrophysiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
10.30
自引率
5.70%
发文量
250
期刊介绍: JACC: Clinical Electrophysiology is one of a family of specialist journals launched by the renowned Journal of the American College of Cardiology (JACC). It encompasses all aspects of the epidemiology, pathogenesis, diagnosis and treatment of cardiac arrhythmias. Submissions of original research and state-of-the-art reviews from cardiology, cardiovascular surgery, neurology, outcomes research, and related fields are encouraged. Experimental and preclinical work that directly relates to diagnostic or therapeutic interventions are also encouraged. In general, case reports will not be considered for publication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书