Evaluation of a multiple myeloma synthetic cell mimic as an assay control for flow cytometry.

IF 2.9 3区 医学 Q3 MEDICAL LABORATORY TECHNOLOGY
Dhong Hyun Lee, Mike Liu, Kanwal Palla, Subhanip Biswas, Swetha Pratyusha Gunturu, Brian Kerfs, Kristine Valenteros, Sarah Kotanchiyev, Shari Kaiser, Justine Dell'Aringa
{"title":"Evaluation of a multiple myeloma synthetic cell mimic as an assay control for flow cytometry.","authors":"Dhong Hyun Lee, Mike Liu, Kanwal Palla, Subhanip Biswas, Swetha Pratyusha Gunturu, Brian Kerfs, Kristine Valenteros, Sarah Kotanchiyev, Shari Kaiser, Justine Dell'Aringa","doi":"10.1002/cyto.b.70075","DOIUrl":null,"url":null,"abstract":"<p><p>The reliability of clinical flow cytometry assays hinges on the availability of robust assay controls that accurately reflect representative samples. Widely used conventional assay controls, such as cell lines, often fail to replicate the phenotypical and biophysical properties of representative primary samples resulting in gating variability and limited confidence in assay performance as certain markers may not be expressed. To address these limitations, we developed a custom synthetic multiple myeloma (MM) cell mimic using Slingshot Biosciences TruCytes® technology. Currently, the MM1.S cell line can be used as an assay control in a flow cytometry panel to evaluate key markers, B cell maturation antigen (BCMA) and G protein-coupled receptor, class C, group 5, member D (GPRC5D), on plasma cells (PCs) and B cells in bone marrow aspirate, for MM clinical trials. Although MM.1S shows strong expression of the key markers BCMA and GPRC5D, it lacks CD45 and CD19 which are needed for PC and B cell identification. We aimed to engineer a MM cell mimic to simulate the scatter properties and antigen density for our fresh MM bone marrow aspirate sample testing. Representative MM bone marrow mononuclear cells (BMMCs) were reviewed to find scatter properties and representative median fluorescence intensity (MFI) of CD45, CD19, CD38, CD138, BCMA, GPRC5D, CD56, and PD-L1 on PCs and B cells. We engineered the MM cell mimic with one population representing PCs and another population representing B cells, based on MM BMMC samples. The MM cell mimic overcame the lack of CD45 and CD19 expression and the divergent scatter and MFI profiles observed in traditional MM cell lines like MM1.S. Qualification studies demonstrated intra- and inter-assay precision (%CV ≤20%), robust inter-instrument reproducibility, post-reconstitution stability up to 7 days at 4°C, and closed-vial storage stability of up to 13 months at -20°C. In summary, these results establish the MM mimics as an improved and alternate assay control to MM1.S, facilitating longitudinal assay performance monitoring and ongoing quality assurance in clinical flow cytometry.</p>","PeriodicalId":10883,"journal":{"name":"Cytometry Part B: Clinical Cytometry","volume":" ","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2026-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cytometry Part B: Clinical Cytometry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/cyto.b.70075","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The reliability of clinical flow cytometry assays hinges on the availability of robust assay controls that accurately reflect representative samples. Widely used conventional assay controls, such as cell lines, often fail to replicate the phenotypical and biophysical properties of representative primary samples resulting in gating variability and limited confidence in assay performance as certain markers may not be expressed. To address these limitations, we developed a custom synthetic multiple myeloma (MM) cell mimic using Slingshot Biosciences TruCytes® technology. Currently, the MM1.S cell line can be used as an assay control in a flow cytometry panel to evaluate key markers, B cell maturation antigen (BCMA) and G protein-coupled receptor, class C, group 5, member D (GPRC5D), on plasma cells (PCs) and B cells in bone marrow aspirate, for MM clinical trials. Although MM.1S shows strong expression of the key markers BCMA and GPRC5D, it lacks CD45 and CD19 which are needed for PC and B cell identification. We aimed to engineer a MM cell mimic to simulate the scatter properties and antigen density for our fresh MM bone marrow aspirate sample testing. Representative MM bone marrow mononuclear cells (BMMCs) were reviewed to find scatter properties and representative median fluorescence intensity (MFI) of CD45, CD19, CD38, CD138, BCMA, GPRC5D, CD56, and PD-L1 on PCs and B cells. We engineered the MM cell mimic with one population representing PCs and another population representing B cells, based on MM BMMC samples. The MM cell mimic overcame the lack of CD45 and CD19 expression and the divergent scatter and MFI profiles observed in traditional MM cell lines like MM1.S. Qualification studies demonstrated intra- and inter-assay precision (%CV ≤20%), robust inter-instrument reproducibility, post-reconstitution stability up to 7 days at 4°C, and closed-vial storage stability of up to 13 months at -20°C. In summary, these results establish the MM mimics as an improved and alternate assay control to MM1.S, facilitating longitudinal assay performance monitoring and ongoing quality assurance in clinical flow cytometry.

评价多发性骨髓瘤合成细胞模拟物作为流式细胞术的测定对照。
临床流式细胞术检测的可靠性取决于可靠的检测控制,准确反映代表性样品的可用性。广泛使用的传统分析对照,如细胞系,经常不能复制代表性主要样品的表型和生物物理特性,导致门控变异性和有限的分析性能的信心,因为某些标记可能无法表达。为了解决这些限制,我们使用Slingshot Biosciences TruCytes®技术开发了定制的合成多发性骨髓瘤(MM)细胞模拟物。目前,MM1。S细胞系可作为流式细胞术面板的检测对照,用于评估骨髓抽吸浆细胞(PCs)和B细胞的关键标志物,B细胞成熟抗原(BCMA)和G蛋白偶联受体,C类,5组,成员D (GPRC5D),用于MM临床试验。虽然MM.1S强烈表达关键标记BCMA和GPRC5D,但缺乏PC和B细胞鉴定所需的CD45和CD19。我们的目标是设计一个MM细胞模拟物来模拟我们新鲜MM骨髓抽吸样本测试的散射特性和抗原密度。对具有代表性的MM骨髓单个核细胞(BMMCs)进行分析,发现CD45、CD19、CD38、CD138、BCMA、GPRC5D、CD56和PD-L1在pc和B细胞上的散射特性和代表性中位荧光强度(MFI)。基于MM BMMC样本,我们设计了MM细胞模拟,其中一个群体代表pc细胞,另一个群体代表B细胞。MM细胞模拟克服了CD45和CD19表达的缺乏以及传统MM细胞系(如MM1.S)中观察到的分散和MFI分布的差异。鉴定研究表明,检测内和检测间的精密度(%CV≤20%),仪器间的重现性强,重构后在4°C下的稳定性可达7天,在-20°C下的闭瓶储存稳定性可达13个月。总之,这些结果表明MM模拟物是MM1的改进和替代对照。S,促进临床流式细胞术的纵向检测性能监测和持续质量保证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.80
自引率
32.40%
发文量
51
审稿时长
>12 weeks
期刊介绍: Cytometry Part B: Clinical Cytometry features original research reports, in-depth reviews and special issues that directly relate to and palpably impact clinical flow, mass and image-based cytometry. These may include clinical and translational investigations important in the diagnostic, prognostic and therapeutic management of patients. Thus, we welcome research papers from various disciplines related [but not limited to] hematopathologists, hematologists, immunologists and cell biologists with clinically relevant and innovative studies investigating individual-cell analytics and/or separations. In addition to the types of papers indicated above, we also welcome Letters to the Editor, describing case reports or important medical or technical topics relevant to our readership without the length and depth of a full original report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书