Ultraviolet irradiation and the home microbiome in childhood asthma: An exploratory environmental analysis.

IF 2 3区 医学 Q2 ALLERGY
Allergy and asthma proceedings Pub Date : 2026-11-01 Epub Date: 2026-10-06 DOI:10.2500/aap.2026.47.260079
Kaleb Ware, Nicholas Ollberding, Qing Duan, David Haslam, Wanda Phipatanakul, Mark Glazman, Jonathan A Bernstein
{"title":"Ultraviolet irradiation and the home microbiome in childhood asthma: An exploratory environmental analysis.","authors":"Kaleb Ware, Nicholas Ollberding, Qing Duan, David Haslam, Wanda Phipatanakul, Mark Glazman, Jonathan A Bernstein","doi":"10.2500/aap.2026.47.260079","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Ultraviolet (UV) filtration units installed into central heating, ventilation, and air conditioning systems have been shown to modify indoor environmental microbiomes (EM), but it remains unclear whether central UV air filtration systems as a targeted intervention alters the EM sufficiently to modify asthma outcomes. <b>Objective:</b> The objective was to investigate changes in the microbiome from dust samples collected before and after installation of a central UV filtration system in homes of children with mild-moderate persistent asthma. <b>Methods:</b> Enrolled pediatric subjects with asthma were randomized to receive UV filtration or sham devices in their heating, ventilation, and air conditioning units. Dust samples were collected from the furnace filters and each child's bedroom inflow air ducts from the first 20 homes randomized at the two largest recruiting sites at the time of device placement and at study completion (12 months), along with periodic measurements of asthma outcomes markers by using the Composite Asthma Severity Index. Microbial DNA from each paired dust sample underwent shotgun metagenomic sequencing, and taxonomic profiles were generated with MetaPhlAn 4. Associations between changes in bacterial species abundance and changes in asthma severity were assessed with Microbiome Multivariable Associations with Linear Models in R. <b>Results:</b> A total of 14 paired dust samples (7 from the UV homes and 7 from the sham homes) from inflow air ducts with sufficient quantity of dust were included for EM analysis. Within the UV filtration homes, false discovery rate adjusted q-values < 0.05 identified associations between worsening asthma severity and reduced relative abundance of common gastrointestinal commensals, such as Bacteroides and Bifidobacterium, previously linked to a reduced risk of allergic disease and asthma; no associations at this threshold were observed in the sham homes. <b>Conclusion:</b> An exploratory study of UV air filtration units installed in homes of children with asthma identified hypothesis-generating associations between bacterial species changes and asthma severity; because the study was underpowered for between-arm comparisons, these findings do not establish that UV air filtration caused the microbiome changes and should not be interpreted as confirmatory of a UV-specific effect.Clinical trial NCT02715375, <ext-link xmlns:xlink=\"http://www.w3.org/1999/xlink\" ext-link-type=\"uri\" xlink:href=\"http://www.clinicaltrials.gov\">www.clinicaltrials.gov</ext-link>.</p>","PeriodicalId":7646,"journal":{"name":"Allergy and asthma proceedings","volume":" ","pages":"394-398"},"PeriodicalIF":2.0000,"publicationDate":"2026-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Allergy and asthma proceedings","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2500/aap.2026.47.260079","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/10/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ALLERGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Ultraviolet (UV) filtration units installed into central heating, ventilation, and air conditioning systems have been shown to modify indoor environmental microbiomes (EM), but it remains unclear whether central UV air filtration systems as a targeted intervention alters the EM sufficiently to modify asthma outcomes. Objective: The objective was to investigate changes in the microbiome from dust samples collected before and after installation of a central UV filtration system in homes of children with mild-moderate persistent asthma. Methods: Enrolled pediatric subjects with asthma were randomized to receive UV filtration or sham devices in their heating, ventilation, and air conditioning units. Dust samples were collected from the furnace filters and each child's bedroom inflow air ducts from the first 20 homes randomized at the two largest recruiting sites at the time of device placement and at study completion (12 months), along with periodic measurements of asthma outcomes markers by using the Composite Asthma Severity Index. Microbial DNA from each paired dust sample underwent shotgun metagenomic sequencing, and taxonomic profiles were generated with MetaPhlAn 4. Associations between changes in bacterial species abundance and changes in asthma severity were assessed with Microbiome Multivariable Associations with Linear Models in R. Results: A total of 14 paired dust samples (7 from the UV homes and 7 from the sham homes) from inflow air ducts with sufficient quantity of dust were included for EM analysis. Within the UV filtration homes, false discovery rate adjusted q-values < 0.05 identified associations between worsening asthma severity and reduced relative abundance of common gastrointestinal commensals, such as Bacteroides and Bifidobacterium, previously linked to a reduced risk of allergic disease and asthma; no associations at this threshold were observed in the sham homes. Conclusion: An exploratory study of UV air filtration units installed in homes of children with asthma identified hypothesis-generating associations between bacterial species changes and asthma severity; because the study was underpowered for between-arm comparisons, these findings do not establish that UV air filtration caused the microbiome changes and should not be interpreted as confirmatory of a UV-specific effect.Clinical trial NCT02715375, www.clinicaltrials.gov.

紫外线照射与儿童哮喘的家庭微生物群:探索性环境分析。
背景:安装在中央供暖、通风和空调系统中的紫外线(UV)过滤装置已被证明可以改变室内环境微生物组(EM),但尚不清楚中央紫外线空气过滤系统作为一种有针对性的干预措施是否足以改变EM以改变哮喘结局。目的:目的是调查在轻度至中度持续性哮喘儿童家中安装中央紫外线过滤系统前后收集的灰尘样本中微生物组的变化。方法:纳入的哮喘儿童受试者被随机分配在他们的供暖、通风和空调装置中使用紫外线过滤或假装置。在装置放置时和研究完成时(12个月),从两个最大的招募点随机抽取的前20个家庭的炉子过滤器和每个孩子的卧室进气管道中收集灰尘样本,并通过使用复合哮喘严重程度指数定期测量哮喘结局标志物。对每对粉尘样本的微生物DNA进行散弹枪宏基因组测序,并利用MetaPhlAn 4生成分类图谱。细菌种类丰度的变化与哮喘严重程度的变化之间的关系通过微生物组多变量关联线性模型进行了评估。结果:来自有足够粉尘量的流入空气管道的14个成对粉尘样本(7个来自紫外线家庭,7个来自假家庭)被纳入EM分析。在使用紫外线过滤的家庭中,错误发现率调整后的q值< 0.05确定了哮喘严重程度恶化与常见胃肠道共生菌(如拟杆菌和双歧杆菌)相对丰度降低之间的关联,这些共生菌先前与过敏性疾病和哮喘风险降低有关;在模拟家庭中没有观察到这个阈值的关联。结论:在哮喘儿童家中安装紫外线空气过滤装置的探索性研究确定了细菌种类变化与哮喘严重程度之间的假设关联;由于该研究在两组比较方面的能力不足,因此这些发现并不能确定紫外线空气过滤导致了微生物组的变化,也不应被解释为证实了紫外线特异性效应。临床试验NCT02715375, www.Clinicaltrials: gov。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.70
自引率
35.70%
发文量
106
审稿时长
6-12 weeks
期刊介绍: Allergy & Asthma Proceedings is a peer reviewed publication dedicated to distributing timely scientific research regarding advancements in the knowledge and practice of allergy, asthma and immunology. Its primary readership consists of allergists and pulmonologists. The goal of the Proceedings is to publish articles with a predominantly clinical focus which directly impact quality of care for patients with allergic disease and asthma. Featured topics include asthma, rhinitis, sinusitis, food allergies, allergic skin diseases, diagnostic techniques, allergens, and treatment modalities. Published material includes peer-reviewed original research, clinical trials and review articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书