Implementation of a mixed-mode liquid chromatography-based analysis to assess fluorinated inorganic anions and (ultra)-short chain PFAS contamination in surface waters.

IF 4.1 2区 化学 Q1 BIOCHEMICAL RESEARCH METHODS
Miriam Haußecker, Simon Bertels, Bernat Oró-Nolla, Christian Zwiener
{"title":"Implementation of a mixed-mode liquid chromatography-based analysis to assess fluorinated inorganic anions and (ultra)-short chain PFAS contamination in surface waters.","authors":"Miriam Haußecker, Simon Bertels, Bernat Oró-Nolla, Christian Zwiener","doi":"10.1007/s00216-026-06841-3","DOIUrl":null,"url":null,"abstract":"<p><p>Ultra-short-chain (USC) per- and polyfluoroalkyl substances (PFAS) are polar, mobile, and persistent and are increasingly focused on because of their widespread occurrence in various environmental matrices. One reason why they were previously often overlooked is their insufficient retention in reversed-phase liquid chromatography which is the standard analytical method in most laboratories for PFAS analysis. In this study, a method using mixed-mode liquid chromatography (MMLC) coupled to tandem mass spectrometry (MS/MS) was optimized for the detection and quantification of five USC PFAS (C<sub>2</sub> and C<sub>3</sub> perfluorocarboxylic acids (PFCAs) and C<sub>1</sub> to C<sub>3</sub> perfluorosulfonic acids (PFSAs)), four short-chain (SC) PFAS (C<sub>4</sub>-C<sub>6</sub> PFCAs and C<sub>4</sub> PFSA), bis(trifluoromethane)sulfonimide (NTf2), and the three fluorinated inorganic anions (FIAs): tetrafluoroborate (BF<sub>4</sub><sup>-</sup>), hexafluorophosphate (PF<sub>6</sub><sup>-</sup>), and hexafluoroarsenate (AsF<sub>6</sub><sup>-</sup>). To investigate the conditions for optimal retention, different eluent constitutions were tested combining varying solvents and additives. USC PFAS could be analyzed using neutral conditions in the aqueous (A) and basic conditions in the organic eluent (B) whereas FIAs were measured with acidified A and basic B. The method was validated and matrix effects were corrected with mass-labeled standards and standard addition. The method was successfully applied to three surface water samples in which eight PFAS could be quantified. TFA and PF<sub>6</sub><sup>-</sup> were found with the highest concentrations at 2.70 µg/L and 0.287 µg/L, respectively, while all other target PFAS occurred in the lower ng/L range. Thus, the sum concentration of TFA and PF<sub>6</sub><sup>-</sup> accounted for more than 97% of the total PFAS concentration in all samples.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":" ","pages":""},"PeriodicalIF":4.1000,"publicationDate":"2026-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-026-06841-3","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Ultra-short-chain (USC) per- and polyfluoroalkyl substances (PFAS) are polar, mobile, and persistent and are increasingly focused on because of their widespread occurrence in various environmental matrices. One reason why they were previously often overlooked is their insufficient retention in reversed-phase liquid chromatography which is the standard analytical method in most laboratories for PFAS analysis. In this study, a method using mixed-mode liquid chromatography (MMLC) coupled to tandem mass spectrometry (MS/MS) was optimized for the detection and quantification of five USC PFAS (C2 and C3 perfluorocarboxylic acids (PFCAs) and C1 to C3 perfluorosulfonic acids (PFSAs)), four short-chain (SC) PFAS (C4-C6 PFCAs and C4 PFSA), bis(trifluoromethane)sulfonimide (NTf2), and the three fluorinated inorganic anions (FIAs): tetrafluoroborate (BF4-), hexafluorophosphate (PF6-), and hexafluoroarsenate (AsF6-). To investigate the conditions for optimal retention, different eluent constitutions were tested combining varying solvents and additives. USC PFAS could be analyzed using neutral conditions in the aqueous (A) and basic conditions in the organic eluent (B) whereas FIAs were measured with acidified A and basic B. The method was validated and matrix effects were corrected with mass-labeled standards and standard addition. The method was successfully applied to three surface water samples in which eight PFAS could be quantified. TFA and PF6- were found with the highest concentrations at 2.70 µg/L and 0.287 µg/L, respectively, while all other target PFAS occurred in the lower ng/L range. Thus, the sum concentration of TFA and PF6- accounted for more than 97% of the total PFAS concentration in all samples.

实施基于混合模式液相色谱的分析,以评估地表水中的氟化无机阴离子和(超)短链PFAS污染。
超短链(USC)全氟烷基和多氟烷基物质(PFAS)具有极性、流动性和持久性,因其广泛存在于各种环境基质中而日益受到关注。它们以前经常被忽视的一个原因是它们在反相液相色谱法中保留不足,而反相液相色谱法是大多数实验室分析PFAS的标准分析方法。本研究优化了混合模式液相色谱(MMLC)耦合串联质谱(MS/MS)检测和定量5种USC PFAS (C2和C3全氟羧酸(PFCAs)和C1至C3全氟磺酸(PFSAs))、4种短链(SC) PFAS (C4- c6 PFCAs和C4 PFSA)、二(三氟甲烷)磺酰亚胺(NTf2)和3种氟化无机阴离子(FIAs)的方法:四氟硼酸盐(BF4-)、六氟磷酸盐(PF6-)和六氟胂酸盐(AsF6-)。为了研究最佳保留条件,我们测试了不同溶剂和添加剂组成的不同洗脱液。USC PFAS可以在水溶液(A)和有机洗脱液(B)的中性条件下进行分析,而FIAs则可以在酸化的A和碱性的B下进行测量。该方法成功地应用于3种地表水样品,其中8种PFAS可以定量。TFA和PF6-的浓度最高,分别为2.70µg/L和0.287µg/L,而其他靶PFAS的浓度均在较低的ng/L范围内。因此,TFA和PF6-的浓度之和占所有样品中总PFAS浓度的97%以上。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.00
自引率
4.70%
发文量
638
审稿时长
2.1 months
期刊介绍: Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书