Real-time process analysis and optimization of nitroguanidine synthesis in microflow using inline Raman spectroscopy.

IF 4.1 2区 化学 Q1 BIOCHEMICAL RESEARCH METHODS
L Hirschberger, M B R Völkl, K Karaghiosoff, T M Klapötke, C Haisch
{"title":"Real-time process analysis and optimization of nitroguanidine synthesis in microflow using inline Raman spectroscopy.","authors":"L Hirschberger, M B R Völkl, K Karaghiosoff, T M Klapötke, C Haisch","doi":"10.1007/s00216-026-06847-x","DOIUrl":null,"url":null,"abstract":"<p><p>Non-contact inline Raman spectroscopy is used as a fast, flexible, and safe method for monitoring and optimizing continuous-flow processes involving highly hazardous and corrosive materials. The synthesis of nitroguanidine (NQ), an energetic material, was characterized and optimized as a model for hazardous reactions. The contactless, flexible, and real-time analysis in this environment was implemented using a clip-on adapter for a Raman probe downstream of the microflow reactor. Initial experiments focus on characterizing the in situ formation of the nitration agent, the nitronium ion (NO<sub>2</sub><sup>+</sup>), and identifying an optimal nitric acid volume fraction between 10 and 20% v/v for maximum NO<sub>2</sub><sup>+</sup> yield. The PAT setup was then used to rapidly optimize reaction parameters (residence time, reactor temperature, and stoichiometry) to enhance reactor output while maintaining high yield. Increasing the reaction temperature to 70 °C effectively reduces system pressure due to the lower viscosity of the reaction stream, while simultaneously increasing yield. Reduced residence times enable higher output with only minimal yield loss (6.3 min, 97%). The analysis of the molar ratio of the reagents further revealed that using a slight excess of nitric acid maintains the yield while avoiding product losses due to back reaction during subsequent processing. To verify the long-term repeatability of the reactor for synthesis, the reaction was performed several times under optimized conditions.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":" ","pages":""},"PeriodicalIF":4.1000,"publicationDate":"2026-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-026-06847-x","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Non-contact inline Raman spectroscopy is used as a fast, flexible, and safe method for monitoring and optimizing continuous-flow processes involving highly hazardous and corrosive materials. The synthesis of nitroguanidine (NQ), an energetic material, was characterized and optimized as a model for hazardous reactions. The contactless, flexible, and real-time analysis in this environment was implemented using a clip-on adapter for a Raman probe downstream of the microflow reactor. Initial experiments focus on characterizing the in situ formation of the nitration agent, the nitronium ion (NO2+), and identifying an optimal nitric acid volume fraction between 10 and 20% v/v for maximum NO2+ yield. The PAT setup was then used to rapidly optimize reaction parameters (residence time, reactor temperature, and stoichiometry) to enhance reactor output while maintaining high yield. Increasing the reaction temperature to 70 °C effectively reduces system pressure due to the lower viscosity of the reaction stream, while simultaneously increasing yield. Reduced residence times enable higher output with only minimal yield loss (6.3 min, 97%). The analysis of the molar ratio of the reagents further revealed that using a slight excess of nitric acid maintains the yield while avoiding product losses due to back reaction during subsequent processing. To verify the long-term repeatability of the reactor for synthesis, the reaction was performed several times under optimized conditions.

利用内嵌拉曼光谱对微流中硝基胍合成的实时过程分析和优化。
非接触式内联拉曼光谱是一种快速、灵活和安全的方法,用于监测和优化涉及高度危险和腐蚀性材料的连续流过程。硝基胍(NQ)是一种含能材料,对其合成进行了表征和优化,并作为危险反应的模型。在这种环境下,使用微流反应器下游拉曼探针的夹式适配器实现了非接触式、灵活的实时分析。最初的实验重点是表征硝化剂氮离子(NO2+)的原位形成,并确定最大NO2+产量的最佳硝酸体积分数在10 ~ 20% v/v之间。然后,PAT设置用于快速优化反应参数(停留时间、反应器温度和化学计量),以提高反应器产量,同时保持高产量。将反应温度提高到70℃,由于反应流粘度降低,有效降低了系统压力,同时提高了产率。减少停留时间,以最小的产量损失(6.3分钟,97%)实现更高的产量。试剂的摩尔比分析进一步表明,使用少量过量的硝酸保持了产率,同时避免了后续加工中由于反反应而造成的产品损失。为了验证合成反应器的长期重复性,在优化条件下进行了多次反应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.00
自引率
4.70%
发文量
638
审稿时长
2.1 months
期刊介绍: Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书