Real-time integrated and multiplexed electrochemical sensor for reactive oxygen species in a high-throughput microphysiological system.

IF 6.3 2区 工程技术 Q1 BIOCHEMICAL RESEARCH METHODS
Lab on a Chip Pub Date : 2026-10-02 DOI:10.1039/d6lc00601a
William C Records, Brian P Cain, Norman F Sheppard, Michael J Matranga, Carlos A Segura, Cáit Ní Chléirigh, Anthony J Quinnert, WeiXuan Lai, Stephan Pretorius, Christian E Wells, Daniel T Conroy, Landys Lopez-Quezada, Zachary R Tranchemontagne, Brenna Rosso, Rebeccah J Luu, Anjana Jeyaram, Halee Kim, Rose Keating, Jeffrey Ma, Liana Kramer, Vidhya Vijayakumar, Jeffrey T Borenstein, Jonathan R Coppeta, Hesham Azizgolshani
{"title":"Real-time integrated and multiplexed electrochemical sensor for reactive oxygen species in a high-throughput microphysiological system.","authors":"William C Records, Brian P Cain, Norman F Sheppard, Michael J Matranga, Carlos A Segura, Cáit Ní Chléirigh, Anthony J Quinnert, WeiXuan Lai, Stephan Pretorius, Christian E Wells, Daniel T Conroy, Landys Lopez-Quezada, Zachary R Tranchemontagne, Brenna Rosso, Rebeccah J Luu, Anjana Jeyaram, Halee Kim, Rose Keating, Jeffrey Ma, Liana Kramer, Vidhya Vijayakumar, Jeffrey T Borenstein, Jonathan R Coppeta, Hesham Azizgolshani","doi":"10.1039/d6lc00601a","DOIUrl":null,"url":null,"abstract":"<p><p>The integration of real-time sensors in microphysiological systems (MPS) faces steep challenges due to the mass transport limitations inherent to microfluidic environments, complex microdevice fabrication methods, and maintenance of long-term performance at high throughput. Reactive oxygen species (ROS) represent attractive yet elusive sensing targets for MPS due to their integral role in cellular metabolism, oxidative homeostasis, and response to disease and injury. Nevertheless, without real-time measurement, their short-lived nature limits practical investigations of ROS as biomarkers in biomedical research. In this work, we have integrated a 96-plex, real-time ROS measurement system into PREDICT96, a high-throughput MPS platform, as a first demonstration of a highly multiplexed electrochemical sensor capability. The ROS measurement system comprises a miniaturized amperometric sensor array capable of rapidly measuring H<sub>2</sub>O<sub>2</sub>, a prototypical ROS, at micromolar concentrations (1-10 μM) with high sensitivity and selectivity across 96 microphysiological devices. Integrated microfluidic pumping enables active mixing during measurement and supports the detection of targets with low concentrations or short lifetimes. This novel capability will enable future work investigating ROS as biomarkers for disease modeling and medical countermeasure evaluation, targeting viral respiratory infections of lung-immune tissue models.</p>","PeriodicalId":85,"journal":{"name":"Lab on a Chip","volume":" ","pages":""},"PeriodicalIF":6.3000,"publicationDate":"2026-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lab on a Chip","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1039/d6lc00601a","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

The integration of real-time sensors in microphysiological systems (MPS) faces steep challenges due to the mass transport limitations inherent to microfluidic environments, complex microdevice fabrication methods, and maintenance of long-term performance at high throughput. Reactive oxygen species (ROS) represent attractive yet elusive sensing targets for MPS due to their integral role in cellular metabolism, oxidative homeostasis, and response to disease and injury. Nevertheless, without real-time measurement, their short-lived nature limits practical investigations of ROS as biomarkers in biomedical research. In this work, we have integrated a 96-plex, real-time ROS measurement system into PREDICT96, a high-throughput MPS platform, as a first demonstration of a highly multiplexed electrochemical sensor capability. The ROS measurement system comprises a miniaturized amperometric sensor array capable of rapidly measuring H2O2, a prototypical ROS, at micromolar concentrations (1-10 μM) with high sensitivity and selectivity across 96 microphysiological devices. Integrated microfluidic pumping enables active mixing during measurement and supports the detection of targets with low concentrations or short lifetimes. This novel capability will enable future work investigating ROS as biomarkers for disease modeling and medical countermeasure evaluation, targeting viral respiratory infections of lung-immune tissue models.

高通量微生理系统中活性氧的实时集成多路电化学传感器。
由于微流体环境固有的质量传输限制、复杂的微器件制造方法以及在高通量下保持长期性能,实时传感器在微生理系统(MPS)中的集成面临着严峻的挑战。活性氧(ROS)在细胞代谢、氧化稳态以及对疾病和损伤的反应中发挥着不可或缺的作用,是MPS的一个有吸引力但又难以捉摸的传感靶标。然而,如果没有实时测量,它们的短暂性限制了ROS作为生物医学研究中生物标志物的实际研究。在这项工作中,我们将96路实时ROS测量系统集成到PREDICT96中,这是一个高通量MPS平台,作为高度多路电化学传感器能力的首次演示。ROS测量系统包括一个小型化的安培传感器阵列,能够快速测量H2O2,一种典型的ROS,在微摩尔浓度(1-10 μM),具有高灵敏度和选择性的96微生理设备。集成的微流体泵可以在测量过程中进行主动混合,并支持检测低浓度或短寿命的目标。这种新能力将使未来研究ROS作为疾病建模和医疗对策评估的生物标志物的工作成为可能,针对肺部免疫组织模型的病毒性呼吸道感染。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Lab on a Chip
Lab on a Chip 工程技术-化学综合
CiteScore
11.10
自引率
8.20%
发文量
434
审稿时长
2.6 months
期刊介绍: Lab on a Chip is the premiere journal that publishes cutting-edge research in the field of miniaturization. By their very nature, microfluidic/nanofluidic/miniaturized systems are at the intersection of disciplines, spanning fundamental research to high-end application, which is reflected by the broad readership of the journal. Lab on a Chip publishes two types of papers on original research: full-length research papers and communications. Papers should demonstrate innovations, which can come from technical advancements or applications addressing pressing needs in globally important areas. The journal also publishes Comments, Reviews, and Perspectives.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书