Gaia Giubilei;Farah Ben Ayed;Pietro Simeoni;Zhenyun Qian;Matteo Rinaldi
{"title":"Experimental Characterization and Optimization of Palladium-Coated Laterally Vibrating Resonators for High-Sensitivity Hydrogen Sensing","authors":"Gaia Giubilei;Farah Ben Ayed;Pietro Simeoni;Zhenyun Qian;Matteo Rinaldi","doi":"10.1109/JMEMS.2026.3721013","DOIUrl":null,"url":null,"abstract":"This paper presents the experimental characterization and optimization of palladium (Pd)-coated aluminum nitride (AlN) laterally vibrating resonators (LVRs) for high-sensitivity hydrogen (H<sub>2</sub>) detection. The sensing mechanism relies on hydrogen-induced biaxial compressive stress in the Pd film, which shifts the resonant frequency through stress-frequency transduction, enabling compact, selective, and high-resolution H<sub>2</sub> monitoring for leak-detection applications. Pd-coated LVRs operating from 123 to 396 MHz were fabricated on a single 4-inch wafer, enabling a controlled study of the combined effects of operating frequency, Pd thickness, and residual stress on electromechanical performance and sensing response. Quality factors reaching <inline-formula> <tex-math>$Q = 1625$ </tex-math></inline-formula> and electromechanical coupling coefficients reaching <inline-formula> <tex-math>$k_{t}^{2} = 1.94\\%$ </tex-math></inline-formula> were achieved, representing a <inline-formula> <tex-math>$2.7\\times $ </tex-math></inline-formula> improvement in Q over prior ScAlN-based implementations. Sensitivity increases monotonically with frequency (15 to 54 Hz/ppm at 123–396 MHz for 100 nm Pd) and with Pd thickness (<inline-formula> <tex-math>$8.5\\times $ </tex-math></inline-formula> from 100 to 200 nm). Residual stress is identified as a previously underreported optimization lever, producing a <inline-formula> <tex-math>$2.6\\times $ </tex-math></inline-formula> sensitivity enhancement for the same Pd thickness. The 317 MHz device with 150 nm Pd is identified as the optimal design point (<inline-formula> <tex-math>$Q = 1411$ </tex-math></inline-formula>, <inline-formula> <tex-math>$k_{t}^{2} = 0.92\\%$ </tex-math></inline-formula>), achieving a peak sensitivity of 772 Hz/ppm in the low-concentration regime with <inline-formula> <tex-math>$t_{90} \\approx 10$ </tex-math></inline-formula> min, establishing Pd-coated AlN LVRs among the most sensitive resonant H<sub>2</sub> sensors reported to date.[ 2026-0081]","PeriodicalId":16621,"journal":{"name":"Journal of Microelectromechanical Systems","volume":"35 5","pages":"923-937"},"PeriodicalIF":3.5000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Microelectromechanical Systems","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11653465/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/12 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
This paper presents the experimental characterization and optimization of palladium (Pd)-coated aluminum nitride (AlN) laterally vibrating resonators (LVRs) for high-sensitivity hydrogen (H2) detection. The sensing mechanism relies on hydrogen-induced biaxial compressive stress in the Pd film, which shifts the resonant frequency through stress-frequency transduction, enabling compact, selective, and high-resolution H2 monitoring for leak-detection applications. Pd-coated LVRs operating from 123 to 396 MHz were fabricated on a single 4-inch wafer, enabling a controlled study of the combined effects of operating frequency, Pd thickness, and residual stress on electromechanical performance and sensing response. Quality factors reaching $Q = 1625$ and electromechanical coupling coefficients reaching $k_{t}^{2} = 1.94\%$ were achieved, representing a $2.7\times $ improvement in Q over prior ScAlN-based implementations. Sensitivity increases monotonically with frequency (15 to 54 Hz/ppm at 123–396 MHz for 100 nm Pd) and with Pd thickness ($8.5\times $ from 100 to 200 nm). Residual stress is identified as a previously underreported optimization lever, producing a $2.6\times $ sensitivity enhancement for the same Pd thickness. The 317 MHz device with 150 nm Pd is identified as the optimal design point ($Q = 1411$ , $k_{t}^{2} = 0.92\%$ ), achieving a peak sensitivity of 772 Hz/ppm in the low-concentration regime with $t_{90} \approx 10$ min, establishing Pd-coated AlN LVRs among the most sensitive resonant H2 sensors reported to date.[ 2026-0081]
期刊介绍:
The topics of interest include, but are not limited to: devices ranging in size from microns to millimeters, IC-compatible fabrication techniques, other fabrication techniques, measurement of micro phenomena, theoretical results, new materials and designs, micro actuators, micro robots, micro batteries, bearings, wear, reliability, electrical interconnections, micro telemanipulation, and standards appropriate to MEMS. Application examples and application oriented devices in fluidics, optics, bio-medical engineering, etc., are also of central interest.