Balloon-Expandable Vs Self-Expanding Valves for Transcatheter Aortic Valve Implantation in Internally Stented Surgical Valves

IF 2.1 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
CJC Open Pub Date : 2026-10-01 Epub Date: 2026-06-29 DOI:10.1016/j.cjco.2026.06.013
Daisuke Sato MD, Noriaki Moriyama MD, Yoichi Sugiyama MD, Hirokazu Miyashita MD, Tomoki Ochiai MD, Koki Shishido MD, Futoshi Yamanaka MD, PhD, Tommi Vähäsilta MD, PhD, Teemu Laakso MD, Sebastian Dahlbacka MD, PhD, Tiina Vainikka MD, PhD, Juho Viikilä MD, Shigeru Saito MD, Mika Laine MD, PhD, Mikko Jalanko MD, PhD
{"title":"Balloon-Expandable Vs Self-Expanding Valves for Transcatheter Aortic Valve Implantation in Internally Stented Surgical Valves","authors":"Daisuke Sato MD,&nbsp;Noriaki Moriyama MD,&nbsp;Yoichi Sugiyama MD,&nbsp;Hirokazu Miyashita MD,&nbsp;Tomoki Ochiai MD,&nbsp;Koki Shishido MD,&nbsp;Futoshi Yamanaka MD, PhD,&nbsp;Tommi Vähäsilta MD, PhD,&nbsp;Teemu Laakso MD,&nbsp;Sebastian Dahlbacka MD, PhD,&nbsp;Tiina Vainikka MD, PhD,&nbsp;Juho Viikilä MD,&nbsp;Shigeru Saito MD,&nbsp;Mika Laine MD, PhD,&nbsp;Mikko Jalanko MD, PhD","doi":"10.1016/j.cjco.2026.06.013","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Internally stented (IS) surgical valves, such as Mitroflow (Sorin Group, Arvada, CO) and Trifecta (St. Jude Medical), are known to carry an elevated risk for coronary artery obstruction during valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) procedures. The data from comparison between balloon-expandable valves (BEVs) and supra-annular self-expanding valves (SEVs) for ViV-TAVI within the IS valve remains unclear. This study aimed to evaluate clinical and hemodynamic outcomes of using BEVs and SEVs for TAVI within an IS valve.</div></div><div><h3>Methods</h3><div>Between January 2016 and February 2024, propensity score–matching was performed between BEV and SEV groups in patients undergoing ViV-TAVI within an IS valve. The data of baseline characteristics, hemodynamic parameters, and clinical outcomes were retrospectively collected. Primary endpoints were 30-day and 2-year clinical outcomes, including all-cause death, hospitalization for heart failure, and coronary obstruction.</div></div><div><h3>Results</h3><div>In total, 113 patients were included in this analysis. A total of 63 patients (55.8%) underwent BEV implantation, and 50 patients (44.2%) underwent SEV implantation. Overall, 37 pairs were identified after propensity-score matching. At day 30, the clinical and hemodynamic outcomes were similar between the groups. Patients with an SEV had better post-procedural mean gradient at 1 year compared with those with a BEV (11.7 ± 4.3 mm Hg vs 22.7 ± 8.4 mm Hg; <em>P</em> &lt; 0.001). No significant difference was observed between SEVs and BEVs in the cumulative 2-year composite endpoint (log-rank <em>P</em> = 0.489).</div></div><div><h3>Conclusions</h3><div>In patients who underwent ViV within an IS valve, the early- and midterm clinical outcomes were comparable between BEVs and SEVs. However, use of an SEV was associated with superior hemodynamics at 1-year follow-up, vs a BEV.</div></div>","PeriodicalId":36924,"journal":{"name":"CJC Open","volume":"8 10","pages":"Pages 1355-1364"},"PeriodicalIF":2.1000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CJC Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2589790X26002611","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/29 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Internally stented (IS) surgical valves, such as Mitroflow (Sorin Group, Arvada, CO) and Trifecta (St. Jude Medical), are known to carry an elevated risk for coronary artery obstruction during valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) procedures. The data from comparison between balloon-expandable valves (BEVs) and supra-annular self-expanding valves (SEVs) for ViV-TAVI within the IS valve remains unclear. This study aimed to evaluate clinical and hemodynamic outcomes of using BEVs and SEVs for TAVI within an IS valve.

Methods

Between January 2016 and February 2024, propensity score–matching was performed between BEV and SEV groups in patients undergoing ViV-TAVI within an IS valve. The data of baseline characteristics, hemodynamic parameters, and clinical outcomes were retrospectively collected. Primary endpoints were 30-day and 2-year clinical outcomes, including all-cause death, hospitalization for heart failure, and coronary obstruction.

Results

In total, 113 patients were included in this analysis. A total of 63 patients (55.8%) underwent BEV implantation, and 50 patients (44.2%) underwent SEV implantation. Overall, 37 pairs were identified after propensity-score matching. At day 30, the clinical and hemodynamic outcomes were similar between the groups. Patients with an SEV had better post-procedural mean gradient at 1 year compared with those with a BEV (11.7 ± 4.3 mm Hg vs 22.7 ± 8.4 mm Hg; P < 0.001). No significant difference was observed between SEVs and BEVs in the cumulative 2-year composite endpoint (log-rank P = 0.489).

Conclusions

In patients who underwent ViV within an IS valve, the early- and midterm clinical outcomes were comparable between BEVs and SEVs. However, use of an SEV was associated with superior hemodynamics at 1-year follow-up, vs a BEV.
经导管主动脉瓣内支架植入中球囊扩张与自膨胀瓣膜的比较
背景:内支架(IS)手术瓣膜,如Mitroflow (Sorin Group, Arvada, CO)和Trifecta (St. Jude Medical),已知在经导管主动脉瓣植入(TAVI)过程中,瓣膜内支架(ViV)会增加冠状动脉阻塞的风险。对于IS阀内的ViV-TAVI,球囊膨胀阀(bev)和超环空自膨胀阀(sev)的比较数据尚不清楚。本研究旨在评估在IS瓣膜内使用bev和sev治疗TAVI的临床和血流动力学结果。方法2016年1月至2024年2月,对在IS瓣膜内行ViV-TAVI的患者进行BEV组和SEV组的倾向评分匹配。回顾性收集基线特征、血流动力学参数和临床结果的数据。主要终点是30天和2年的临床结果,包括全因死亡、心力衰竭住院和冠状动脉阻塞。结果共纳入113例患者。BEV植入63例(55.8%),SEV植入50例(44.2%)。总体而言,在倾向得分匹配后,确定了37对。第30天,两组临床和血流动力学结果相似。与BEV患者相比,SEV患者在1年后的术后平均梯度更好(11.7±4.3 mm Hg vs 22.7±8.4 mm Hg; P < 0.001)。在累积的2年复合终点中,sev和bev之间无显著差异(log-rank P = 0.489)。结论在IS瓣膜内行ViV的患者中,bev和sev的早期和中期临床结果具有可比性。然而,在1年的随访中,SEV的使用与BEV相比具有更好的血流动力学。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CJC Open
CJC Open Medicine-Cardiology and Cardiovascular Medicine
CiteScore
3.30
自引率
0.00%
发文量
143
审稿时长
60 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书