A Cost-Effective IoT-Based Non-Invasive Glucose Monitoring System with Individualized Calibration for Scalable Biomedical Device Production

IF 2.8 Q3 ENGINEERING, MANUFACTURING
Manufacturing Letters Pub Date : 2026-10-01 Epub Date: 2026-10-05 DOI:10.1016/j.mfglet.2026.07.011
Maram Shqair, Konstantinos Mykoniatis
{"title":"A Cost-Effective IoT-Based Non-Invasive Glucose Monitoring System with Individualized Calibration for Scalable Biomedical Device Production","authors":"Maram Shqair,&nbsp;Konstantinos Mykoniatis","doi":"10.1016/j.mfglet.2026.07.011","DOIUrl":null,"url":null,"abstract":"<div><div>This study presents a cost-effective, IoT-enabled, non-invasive glucose monitoring system that employs photoplethysmography (PPG) biosignals and individualized calibration to enhance measurement accuracy and long-term stability. The system integrates the MAX30101 Pulse Oximeter and Heart Rate Sensor for high-fidelity biosignal acquisition and the MAX32664 Biometric Sensor Hub for noise reduction and signal processing. An Arduino Uno R4 WiFi microcontroller with cloud-based storage and real-time dashboards handles data. A personalized polynomial regression model was developed for a single user, as a proof-of-concept. The model uses heart rate (HR) and peripheral capillary oxygen saturation (SpO2) as input features to predict glucose levels, while accounting for physiological variability. Model evaluation demonstrated strong predictive performance, achieving an R<sup>2</sup> of 0.8576 during training and 0.789 during testing, with a mean absolute error (MAE) of 6.58 mg/dL, a root mean square error (RMSE) of 7.75 mg/dL, and a mean absolute relative difference (MARD) of 7.13%. The achieved accuracy is comparable to values reported in the PPG-based non-invasive glucose monitoring literature, while the use of individualized calibration in this study provides a key advantage: tailoring the regression model to each user’s specific physiological characteristics, thereby minimizing the need for frequent recalibration and enhancing long-term stability. To the best of the authors’ knowledge, this is the first low-cost IoT-based glucose monitoring system that combines PPG sensing with individualized calibration. This low-cost proof-of-concept can be generalized and scaled through a structured pathway that progresses from multi-subject clinical validation to engineering design transfer with factory-level verification, followed by broader deployment supported by regulated quality and approval processes.</div></div>","PeriodicalId":38186,"journal":{"name":"Manufacturing Letters","volume":"49 ","pages":"Pages 18-29"},"PeriodicalIF":2.8000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Manufacturing Letters","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2213846326000623","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/10/5 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, MANUFACTURING","Score":null,"Total":0}
引用次数: 0

Abstract

This study presents a cost-effective, IoT-enabled, non-invasive glucose monitoring system that employs photoplethysmography (PPG) biosignals and individualized calibration to enhance measurement accuracy and long-term stability. The system integrates the MAX30101 Pulse Oximeter and Heart Rate Sensor for high-fidelity biosignal acquisition and the MAX32664 Biometric Sensor Hub for noise reduction and signal processing. An Arduino Uno R4 WiFi microcontroller with cloud-based storage and real-time dashboards handles data. A personalized polynomial regression model was developed for a single user, as a proof-of-concept. The model uses heart rate (HR) and peripheral capillary oxygen saturation (SpO2) as input features to predict glucose levels, while accounting for physiological variability. Model evaluation demonstrated strong predictive performance, achieving an R2 of 0.8576 during training and 0.789 during testing, with a mean absolute error (MAE) of 6.58 mg/dL, a root mean square error (RMSE) of 7.75 mg/dL, and a mean absolute relative difference (MARD) of 7.13%. The achieved accuracy is comparable to values reported in the PPG-based non-invasive glucose monitoring literature, while the use of individualized calibration in this study provides a key advantage: tailoring the regression model to each user’s specific physiological characteristics, thereby minimizing the need for frequent recalibration and enhancing long-term stability. To the best of the authors’ knowledge, this is the first low-cost IoT-based glucose monitoring system that combines PPG sensing with individualized calibration. This low-cost proof-of-concept can be generalized and scaled through a structured pathway that progresses from multi-subject clinical validation to engineering design transfer with factory-level verification, followed by broader deployment supported by regulated quality and approval processes.
一种具有成本效益的基于物联网的无创血糖监测系统,可用于可扩展的生物医学设备生产
本研究提出了一种具有成本效益,物联网支持的无创血糖监测系统,该系统采用光体积脉搏波(PPG)生物信号和个性化校准来提高测量精度和长期稳定性。该系统集成了MAX30101脉搏血氧仪和心率传感器,用于高保真生物信号采集,以及MAX32664生物识别传感器集线器,用于降噪和信号处理。Arduino Uno R4 WiFi微控制器与基于云的存储和实时仪表板处理数据。为单个用户开发了个性化的多项式回归模型,作为概念验证。该模型使用心率(HR)和外周毛细血管氧饱和度(SpO2)作为输入特征来预测血糖水平,同时考虑到生理变异性。模型评估显示出较强的预测性能,训练期间的R2为0.8576,测试期间的R2为0.789,平均绝对误差(MAE)为6.58 mg/dL,均方根误差(RMSE)为7.75 mg/dL,平均绝对相对差(MARD)为7.13%。所获得的准确度与基于ppg的无创血糖监测文献报道的值相当,而在本研究中使用个性化校准提供了一个关键优势:根据每个用户的特定生理特征定制回归模型,从而最大限度地减少了频繁重新校准的需要,并增强了长期稳定性。据作者所知,这是第一个低成本的基于物联网的血糖监测系统,将PPG传感与个性化校准相结合。这种低成本的概念验证可以通过一个结构化的途径进行推广和扩展,从多主体临床验证到工程设计转移,再到工厂级验证,然后在规范的质量和批准流程的支持下进行更广泛的部署。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Manufacturing Letters
Manufacturing Letters Engineering-Industrial and Manufacturing Engineering
CiteScore
4.20
自引率
5.10%
发文量
192
审稿时长
60 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书