Rescue Cutting Balloon Angioplasty for Heavily Calcified Carotid Artery Stenosis: A Case Report and Narrative Review.

Minyoul Baik, Dongjin Seo, Joonsang Yoo, Jinkwon Kim
{"title":"Rescue Cutting Balloon Angioplasty for Heavily Calcified Carotid Artery Stenosis: A Case Report and Narrative Review.","authors":"Minyoul Baik, Dongjin Seo, Joonsang Yoo, Jinkwon Kim","doi":"10.1002/ccd.70898","DOIUrl":null,"url":null,"abstract":"<p><p>Carotid artery stenting for heavily calcified lesions (HCLs) poses significant therapeutic challenges. We report an 83-year-old male with symptomatic carotid stenosis of HCLs. Angiography demonstrated 91% stenosis with a minimum lumen diameter (MLD) of 0.4 mm. Standard pre-dilation resulted in a \"dog-bone\" deformity (residual stenosis 74%, MLD 1.1 mm), preventing stent delivery. As a rescue technique, a 3.0 mm Wolverine coronary cutting balloon (Boston Scientific, Marlborough, MA, USA) was employed, successfully increasing the MLD to 2.4 mm without inducing baroreceptor-mediated hemodynamic instability. This luminal gain facilitated the successful delivery and deployment of a self-expanding stent, followed by post-dilation that achieved a final residual stenosis of 19%. A subacute in-stent thrombus detected on post-procedure day 4 resolved completely with intensified antithrombotic therapy, and at 3-month follow-up the patient had no recurrent stroke or in-stent restenosis, with a modified Rankin Scale score of 2. Supported by a literature review, this case demonstrates that newer-generation cutting balloons with improved crossing profiles offer a safe, effective rescue strategy for unyielding carotid HCLs, achieving essential luminal gain while minimizing procedural risks.</p>","PeriodicalId":520583,"journal":{"name":"Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/ccd.70898","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Carotid artery stenting for heavily calcified lesions (HCLs) poses significant therapeutic challenges. We report an 83-year-old male with symptomatic carotid stenosis of HCLs. Angiography demonstrated 91% stenosis with a minimum lumen diameter (MLD) of 0.4 mm. Standard pre-dilation resulted in a "dog-bone" deformity (residual stenosis 74%, MLD 1.1 mm), preventing stent delivery. As a rescue technique, a 3.0 mm Wolverine coronary cutting balloon (Boston Scientific, Marlborough, MA, USA) was employed, successfully increasing the MLD to 2.4 mm without inducing baroreceptor-mediated hemodynamic instability. This luminal gain facilitated the successful delivery and deployment of a self-expanding stent, followed by post-dilation that achieved a final residual stenosis of 19%. A subacute in-stent thrombus detected on post-procedure day 4 resolved completely with intensified antithrombotic therapy, and at 3-month follow-up the patient had no recurrent stroke or in-stent restenosis, with a modified Rankin Scale score of 2. Supported by a literature review, this case demonstrates that newer-generation cutting balloons with improved crossing profiles offer a safe, effective rescue strategy for unyielding carotid HCLs, achieving essential luminal gain while minimizing procedural risks.

紧急切开球囊成形术治疗重度钙化颈动脉狭窄1例报告及叙述回顾。
颈动脉支架植入术治疗重度钙化病变(hcl)提出了重大的治疗挑战。我们报告一个83岁男性颈动脉狭窄症状的hcl。血管造影显示91%狭窄,最小管腔直径(MLD) 0.4 mm。标准的预扩张导致“狗骨”畸形(残留狭窄74%,MLD 1.1 mm),阻碍了支架的植入。作为救援技术,采用3.0 mm金刚狼冠状动脉切割球囊(Boston Scientific, Marlborough, MA, USA),成功地将MLD增加到2.4 mm,而没有引起压力受体介导的血流动力学不稳定。这种管腔增益促进了自扩张支架的成功运送和部署,随后扩张后最终残余狭窄率为19%。术后第4天检测到的亚急性支架内血栓通过强化抗栓治疗完全解决,在3个月的随访中,患者没有复发性卒中或支架内再狭窄,改进的Rankin量表评分为2分。在文献综述的支持下,该病例表明,具有改进的交叉轮廓的新一代切割气球为不屈服的颈动脉hcl提供了一种安全有效的救援策略,在最大限度地降低手术风险的同时获得了必要的管道增益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书